Camera Lens Mount Chart: Flange Distance and Throat

The flange focal distance (FFD) is the distance from a mount's flange to the image plane: 18.0 mm for Sony E, 44.0 mm for Canon EF. A lens can be adapted to another body without glass when its FFD is longer than the body's by at least about 1 mm: the adapter fills exactly the difference, so an EF lens on a Sony E body needs a 26 mm adapter.

33 sizesChecked 2026-11-156 sources
A lens adapts with a plain adapter to any body whose bar is at least ~1 mm shorter: short mirrorless mounts at the top accept almost every lens below them.Drawn to scale

Size chartTap a size for its drawing and full specs

33 of 33
MountFFDFlange focal distancemmin⌀Throat diametermminMount typeSensor / film formatIntroduced
Mirrorless mounts
Nikon Z160.6299552.165BayonetFull frame (FX), APS-C (DX)2018
Sony E / FE180.708746.11.815BayonetFull frame (FE), APS-C (E)2010
Canon EF-M180.7087471.850BayonetAPS-C2012
Fujifilm X17.70.696943.51.713BayonetAPS-C2012
Canon RF200.7874542.126BayonetFull frame, APS-C (RF-S)2018
L-Mount200.787451.62.031BayonetFull frame, APS-C2014
Micro Four Thirds19.250.7579—BayonetFour Thirds (17.3 × 13 mm)2008
Nikon 1170.6693401.575Bayonet1-inch (CX)2011
Samsung NX25.51.0039421.654BayonetAPS-C2010
Pentax Q9.20.3622—Bayonet1/2.3″ and 1/1.7″2011
SLR and rangefinder mounts (35 mm and APS-C)
Canon FD421.6535481.890Breech-lock (locking ring)35 mm film1971
Minolta SR / MD43.51.7126451.772Bayonet35 mm film1958
Canon EF441.7323542.126BayonetFull frame, APS-C, 35 mm film1987
Canon EF-S441.7323542.126BayonetAPS-C only2003
Sony / Minolta A44.51.752049.71.957BayonetFull frame, APS-C, 35 mm film1985
Pentax K45.461.7898441.732BayonetFull frame, APS-C, 35 mm film1975
M42 screw mount45.461.7898421.654Screw thread35 mm film1949
Contax / Yashica (C/Y)45.51.7913481.890Bayonet35 mm film1975
Olympus OM461.8110461.811Bayonet35 mm film1972
Nikon F46.51.8307441.732BayonetFull frame (FX), APS-C (DX), 35 mm film1959
Leica R471.8504—Bayonet35 mm film1964
Four Thirds38.671.5224441.732BayonetFour Thirds (17.3 × 13 mm)2003
Leica M27.81.0945441.732BayonetFull frame, 35 mm film (rangefinder)1954
Medium format mounts
Hasselblad XCD18.140.7142—BayonetMedium format 44 × 33 mm2016
Fujifilm G26.71.0512652.559BayonetMedium format 44 × 33 mm2016
Mamiya 64563.32.4921—Bayonet645 film; digital backs1975
Pentax 64570.872.7902—Bayonet645 film; 44 × 33 mm digital1984
Hasselblad V74.92.9488—Bayonet6 × 6 film; digital backs1957
Pentax 6784.953.3445—Bayonet6 × 7 film1969
Cine and industrial mounts
PL (Arri PL)522.0472542.126Breech-lock (locking ring)Super 35, full frame cine1982
LPL (Arri LPL)441.7323622.441Breech-lock (locking ring)Large format cine (Alexa LF / Mini LF / 65)2018
C-mount17.5260.690025.41.000Screw thread16 mm film, 2/3″ and 1″ video, machine vision—
CS-mount12.5260.493125.41.000Screw threadCCTV and machine vision up to 1/2″—

How to read flange distance and throat

Flange focal distance (also called flange back, register or flange-to-film distance) is measured from the mount's reference face (the metal ring the lens seats against) to the sensor or film. Lenses are designed for exactly this distance; put a lens farther from the sensor and it focuses closer but loses infinity, put it nearer and it cannot focus at all.

Throat diameter is the inner diameter of the mount opening. It limits how large the lens's rear element and mount can be. A lens whose mount is wider than the body's throat can still be adapted mechanically, but large rear elements may vignette or hit the body.

Adapter rule: adapter thickness = lens FFD − body FFD. If the result is at least about 1 mm, a plain adapter with no glass keeps full infinity focus (both bayonets need that much material). Between 0 and 1 mm it is too thin to build; below zero only an adapter with corrective glass works, which costs image quality and acts as a teleconverter.

About Lens Mounts

Mirrorless mounts have short flange distances (16–20 mm) because there is no mirror box between lens and sensor. That is what makes them universal adapters: nearly every SLR lens ever made (Nikon F, Canon EF, Pentax K, M42, Olympus OM, Leica R) has a longer FFD and fits a Sony E, Canon RF, Nikon Z, Fujifilm X, L-Mount or Micro Four Thirds body through a simple tube. The reverse is impossible: a mirrorless lens on an SLR body would sit too far from the sensor.

Among SLR mounts the order matters too. Canon EF (44.0 mm) has one of the shortest SLR registers, so EOS bodies accepted Nikon F (46.5), Pentax K and M42 (45.46), Contax/Yashica (45.5), Olympus OM (46.0) and Leica R (47.0) lenses with thin adapters, while Canon FD (42.0) and Minolta MD (43.5) lenses cannot reach infinity on EOS without glass.

The flange distance is not the only constraint. Electrical contacts (autofocus, aperture control, stabilisation) need a smart adapter that translates between protocols; manual-aperture lenses or lenses with an aperture lever need a mechanical linkage. Sensor size matters: a full-frame lens on APS-C crops the image, an APS-C lens on full frame vignettes.

All values on this page are nominal register distances. Real cameras are adjusted within a few hundredths of a millimetre, and cheap adapters are often made slightly thin so that lenses focus past infinity rather than fall short of it.

Common adapter thicknesses

Canon EF → Sony E: 26.0 mm. Canon EF → Canon RF: 24.0 mm. Nikon F → Nikon Z: 30.5 mm. Nikon F → Sony E: 28.5 mm. Leica M → Sony E: 9.8 mm. M42 → Fujifilm X: 27.76 mm. Pentax K → Canon EF: 1.46 mm. Canon EF → Micro Four Thirds: 24.75 mm. PL → Sony E: 34.0 mm.

Mounts with the same flange distance

Equal FFD does not mean compatible: Sony E and Canon EF-M are both 18.0 mm, Canon RF and L-Mount both 20.0 mm, Pentax K and M42 both 45.46 mm. No glassless adapter can join them because there is no room for two bayonets. (Pentax made a thin K-to-M42 adapter that sits inside the K mount, a special case.) Canon EF and EF-S share the same mount and FFD: EF lenses fit every EF-S body, but EF-S lenses do not fit full-frame EF bodies because their rear element would hit the mirror.

C-mount on mirrorless bodies

C-mount (17.526 mm) is shorter than Micro Four Thirds (19.25 mm), yet C-mount lenses adapt to MFT: the narrow 1-inch thread lets the lens sit recessed inside the 19.25 mm-deep, much wider MFT throat. The same trick works on Sony E and Fujifilm X. Most C-mount lenses only cover 2/3″ or 1″ sensors and vignette heavily on larger formats.

Questions

What is flange focal distance?

The distance from a lens mount's flange (the face the lens seats against) to the sensor or film. Examples: Nikon Z 16.0 mm, Sony E 18.0 mm, Canon RF 20.0 mm, Canon EF 44.0 mm, Nikon F 46.5 mm.

Can I use Canon EF lenses on a Sony camera?

Yes. EF is 44.0 mm and Sony E 18.0 mm, so a 26.0 mm adapter fits. Smart adapters (e.g. from Metabones, Sigma, Viltrox) pass autofocus and aperture signals.

Can I put Nikon F lenses on a Canon EF body?

Yes, with a 2.5 mm adapter (46.5 − 44.0). Aperture and focus are manual; lenses without an aperture ring (Nikon G-type) need an adapter with an aperture lever.

Why can't mirrorless lenses be used on DSLRs?

Their flange distance (16–20 mm) is far shorter than any DSLR's (42–47 mm). On a DSLR the lens would sit 25 mm or more too far from the sensor, so it could only focus at very close range.

Which mount can adapt the most lenses?

The shortest flange distances with a wide throat: Nikon Z (16.0 mm, 55 mm throat), Sony E (18.0 mm), Fujifilm X (17.7 mm), Canon RF and L-Mount (20.0 mm), and Micro Four Thirds (19.25 mm, with a 2× crop).

Sources

  1. Wikipedia: Flange focal distance (table of mounts, with primary references)
  2. Wikipedia: Lens mount (throat diameters, mount types)
  3. Brian Smith: Ultimate guide to flange focal distance
  4. cameramarket: Lens mounts and flange focal distances (adapter reference, PDF)
  5. Edmund Optics: Lens mounts (C-mount and CS-mount flange distances)
  6. Canon Rumors: mount comparison table (EF-M, RF, Sony E, Fujifilm G diameters)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.