UCFL206 Dimensions
Bearing Units (UCP, UCF, UCFL) · UCFL: oval flange (2 bolts)
UCFL206 (UCFL: oval flange, 2 bolts): 30 mm (1.181 in) bore, insert UC206.
- dBore diameter
- 30 mm1.181 in1.181 in30 mm
- JBolt hole spacing
- 117 mm4.606 in4.606 in117 mm
Drawing
UCFL206 specifications
| dBore diameter | 30 mm1.181 in |
|---|---|
| JBolt hole spacing | 117 mm4.606 in |
| LOverall length (typical) | 148 mm5.827 in |
| Insert bearing | UC206 |
| Housing | FL206 |
Overall length varies between makers: 148 mm in the Timken data, 141 mm in one FYH table. Bolt spacing J = 117 mm is the same.
Also known as
UCFL206D1FL206UCFL206-18UCFL206-19UCFL206-20
Same size code: insert and other housings
All Bearing Units (UCP, UCF, UCFL) sizes
Compare all 57 sizes in the Bearing Units (UCP, UCF, UCFL) chart →
Sources
- ISO 3228:2013, Rolling bearings, cast and pressed housings for insert bearings
- ISO 9628: Rolling bearings, insert bearings and eccentric locking collars, boundary dimensions
- JIS B 1558 / JIS B 1559: Rolling bearings, insert bearings and housings
- Timken: UCP, UCF, UCFL mounted units (cad.timken.com part pages)
- FYH: Mounted bearing units catalogue (UCP200, UCF200, UCFL200)
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.