Pillow Block and Flange Bearing Size Chart: UC, UCP, UCF, UCFL
A mounted bearing unit is a UC insert bearing (wide inner ring locked with two set screws) in a cast-iron housing. The number tells you both: UCP205 = UC205 insert (25 mm bore) in a P205 pillow block with a shaft height of 36.5 mm and 105 mm between bolt holes.
Size chartTap a size for its drawing and full specs
| Unit | dBore diametermmin | DInsert outside diametermmin | BInner ring width (insert)mmin | HShaft centre heightmmin | JBolt hole spacingmmin | LOverall length (typical)mmin | ABase width (typical)mmin |
|---|---|---|---|---|---|---|---|
| UC inserts (set screw locking) | |||||||
| UC201 | 120.472 | 471.850 | 311.220 | — | — | — | — |
| UC202 | 150.591 | 471.850 | 311.220 | — | — | — | — |
| UC203 | 170.669 | 471.850 | 311.220 | — | — | — | — |
| UC204 | 200.787 | 471.850 | 311.220 | — | — | — | — |
| UC205 | 250.984 | 522.047 | 34.11.343 | — | — | — | — |
| UC206 | 301.181 | 622.441 | 38.11.500 | — | — | — | — |
| UC207 | 351.378 | 722.835 | 42.91.689 | — | — | — | — |
| UC208 | 401.575 | 803.150 | 49.21.937 | — | — | — | — |
| UC209 | 451.772 | 853.346 | 49.21.937 | — | — | — | — |
| UC210 | 501.969 | 903.543 | 51.62.031 | — | — | — | — |
| UC211 | 552.165 | 1003.937 | 55.62.189 | — | — | — | — |
| UC212 | 602.362 | 1104.331 | 65.12.563 | — | — | — | — |
| UC213 | 652.559 | 1204.724 | 65.12.563 | — | — | — | — |
| UC214 | 702.756 | 1254.921 | 74.62.937 | — | — | — | — |
| UC215 | 752.953 | 1305.118 | 77.83.063 | — | — | — | — |
| UC216 | 803.150 | 1405.512 | 82.63.252 | — | — | — | — |
| UC217 | 853.346 | 1505.906 | 85.73.374 | — | — | — | — |
| UC218 | 903.543 | 1606.299 | 963.780 | — | — | — | — |
| UCP: pillow block (2-bolt base) | |||||||
| UCP204 | 200.787 | — | — | 33.31.311 | 953.740 | 1275.000 | 381.496 |
| UCP205 | 250.984 | — | — | 36.51.437 | 1054.134 | 1405.512 | 381.496 |
| UCP206 | 301.181 | — | — | 42.91.689 | 1214.764 | 1656.496 | 481.890 |
| UCP207 | 351.378 | — | — | 47.61.874 | 1275.000 | 1676.575 | 481.890 |
| UCP208 | 401.575 | — | — | 49.21.937 | 1375.394 | 1847.244 | 542.126 |
| UCP209 | 451.772 | — | — | 542.126 | 1465.748 | 1907.480 | 542.126 |
| UCP210 | 501.969 | — | — | 57.22.252 | 1596.260 | 2068.110 | 602.362 |
| UCP211 | 552.165 | — | — | 63.52.500 | 1716.732 | 2198.622 | 602.362 |
| UCP212 | 602.362 | — | — | 69.82.748 | 1847.244 | 2419.488 | 702.756 |
| UCP213 | 652.559 | — | — | 76.23.000 | 2037.992 | 26510.433 | 702.756 |
| UCP214 | 702.756 | — | — | 79.43.126 | 2108.268 | 26610.472 | 722.835 |
| UCP215 | 752.953 | — | — | 82.63.252 | 2178.543 | 27510.827 | 742.913 |
| UCP216 | 803.150 | — | — | 88.93.500 | 2329.134 | 29211.496 | 783.071 |
| UCP217 | 853.346 | — | — | 95.23.748 | 2479.724 | 31012.205 | 833.268 |
| UCP218 | 903.543 | — | — | 101.64.000 | 26210.315 | 32712.874 | 883.465 |
| UCF: square flange (4 bolts) | |||||||
| UCF204 | 200.787 | — | — | — | 642.520 | 863.386 | — |
| UCF205 | 250.984 | — | — | — | 702.756 | 953.740 | — |
| UCF206 | 301.181 | — | — | — | 833.268 | 1084.252 | — |
| UCF207 | 351.378 | — | — | — | 923.622 | 1174.606 | — |
| UCF208 | 401.575 | — | — | — | 1024.016 | 1305.118 | — |
| UCF209 | 451.772 | — | — | — | 1054.134 | 1375.394 | — |
| UCF210 | 501.969 | — | — | — | 1114.370 | 1435.630 | — |
| UCF211 | 552.165 | — | — | — | 1305.118 | 1626.378 | — |
| UCF212 | 602.362 | — | — | — | 1435.630 | 1756.890 | — |
| UCF213 | 652.559 | — | — | — | 1495.866 | 1877.362 | — |
| UCF214 | 702.756 | — | — | — | 1525.984 | 1937.598 | — |
| UCF215 | 752.953 | — | — | — | 1596.260 | 2007.874 | — |
| UCF216 | 803.150 | — | — | — | 1656.496 | 2088.189 | — |
| UCF217 | 853.346 | — | — | — | 1756.890 | 2208.661 | — |
| UCF218 | 903.543 | — | — | — | 1877.362 | 2359.252 | — |
| UCFL: oval flange (2 bolts) | |||||||
| UCFL204 | 200.787 | — | — | — | 903.543 | 1134.449 | — |
| UCFL205 | 250.984 | — | — | — | 993.898 | 1305.118 | — |
| UCFL206 | 301.181 | — | — | — | 1174.606 | 1485.827 | — |
| UCFL207 | 351.378 | — | — | — | 1305.118 | 1616.339 | — |
| UCFL208 | 401.575 | — | — | — | 1445.669 | 1756.890 | — |
| UCFL209 | 451.772 | — | — | — | 1485.827 | 1887.402 | — |
| UCFL210 | 501.969 | — | — | — | 1576.181 | 1977.756 | — |
| UCFL211 | 552.165 | — | — | — | 1847.244 | 2248.819 | — |
| UCFL212 | 602.362 | — | — | — | 2027.953 | 2509.843 | — |
No exact match. The nearest sizes:
How to read a bearing unit number
UCP 208-24: UC = insert with set screws, P = pillow block housing, 2 = light (200) series, 08 = size code (× 5 = 40 mm bore for codes 04 and up; 01/02/03 = 12/15/17 mm). Other housings: F square 4-bolt flange, FL oval 2-bolt flange, T take-up, FC round flanged cartridge, PA tapped base, FB 3-bolt.
A suffix after a dash is an inch bore in sixteenths: -24 = 24/16 = 1-1/2", -16 = 1", -20 = 1-1/4", -12 = 3/4". The ring and housing are the same as the metric unit of that size code, only the bore differs. UCP208-24 has the housing of a UCP208.
Other insert types fit the same housings when the outer ring is the same: UK (tapered bore with adapter sleeve), SA / UEL / NA (eccentric collar), UB (narrow inner ring). The 300 series (UCP3xx) is a heavier, different size range and does not interchange with 200 series housings.
About Bearing Units (UCP, UCF, UCFL)
The insert's outer ring is ground spherical and sits in a matching spherical seat in the housing. It can therefore tilt a little as it is bolted down (about ±2°) to make up for an imperfect mounting surface. It is not meant to accommodate a shaft that wobbles in operation.
Interchange dimensions are standardised by ISO 3228 and JIS B 1559: the shaft centre height H and the bolt spacing J of a P205 are the same at every maker, so a replacement unit lines up with the old bolt holes and shaft. Overall length, base width and casting shape vary by a few millimetres between brands, which is why the chart marks them as typical.
Lock the set screws only after the shaft is aligned and both units are bolted down, and tighten to the maker's torque (a set screw on a UC205 is M6 × 0.75, typically about 4 N·m). Set screws hold best on a shaft with h7–h9 tolerance; on a heavily loaded or reversing shaft an eccentric collar or adapter sleeve insert lasts longer.
Choosing the housing
Pillow blocks (UCP) bolt to a surface parallel to the shaft; flange units (UCF, UCFL) bolt to a wall the shaft passes through. A 4-bolt square flange is stiffer and centres better; the 2-bolt oval flange needs less space. Take-up units (UCT) slide in a frame to tension conveyor belts.
Questions
What are the dimensions of a UCP205 pillow block?
25 mm bore, shaft centre height 36.5 mm, bolt hole spacing 105 mm, overall length about 140 mm, base width about 38 mm. The insert is a UC205 (52 mm OD, 34.1 mm inner ring width).
What does UCP205-16 mean?
A UCP205 housing and ring with a 1" bore: the -16 suffix is the bore in sixteenths of an inch. UCP205-14 has a 7/8" bore.
Are UCP units from different brands interchangeable?
Yes for the critical dimensions: shaft height H and bolt spacing J follow ISO 3228 / JIS B 1559. Overall length and base width can differ by a few mm.
What is the difference between UCF and UCFL?
UCF is a square flange with four bolt holes; UCFL is an oval (rhombic) flange with two. For a 20 mm bore the UCF204 is 86 mm square with 64 mm bolt spacing; the UCFL204 is 113 mm long with 90 mm between its two bolts.
Can I put a UC205 into a UCP206 housing?
No. The insert outside diameter must match the housing seat: UC205 is 52 mm, the P206 seat is for a 62 mm insert (UC206).
Sources
- ISO 3228:2013, Rolling bearings, cast and pressed housings for insert bearings
- ISO 9628: Rolling bearings, insert bearings and eccentric locking collars, boundary dimensions
- JIS B 1558 / JIS B 1559: Rolling bearings, insert bearings and housings
- Timken: UCP, UCF, UCFL mounted units (cad.timken.com part pages)
- FYH: Mounted bearing units catalogue (UCP200, UCF200, UCFL200)
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.