MC6×7 Channel Dimensions & Properties

C & MC Channels (AISC) · MC shapes: miscellaneous channels

MC6×7 is an AISC MC shapes: miscellaneous channels channel. It is 6 in (152.4 mm) deep with a 1.88 in (47.8 mm) flange, a 0.179 in (4.5 mm) web and an average flange thickness of 0.291 in (7.4 mm), and weighs 7 lb/ft (10.4 kg/m). Area 2.09 in² (1,348 mm²); centroid 0.501 in (12.7 mm) from the back of the web; Ix = 11.4 in⁴ (474.5 cm⁴), Sx = 3.81 in³ (62.4 cm³).

dDepth
152.4 mm6 in6 in152.4 mm
bfFlange width
47.8 mm1.88 in1.88 in47.8 mm
twWeb thickness
4.5 mm0.179 in0.179 in4.5 mm
tfFlange thickness (average)
7.4 mm0.291 in0.291 in7.4 mm

Drawing

47.8 mm1.88 in152.4 mm6 intf 7.4 mmtf 0.291 intw 4.5 mmtw 0.179 ine 12.7 mme 0.501 in
Flanges drawn parallel; MC flange slopes vary by shape.Drawn to scale · Dimensions in mmDimensions in inches

MC6×7 specifications

dDepth6 in152.4 mm
bfFlange width1.88 in47.8 mm
twWeb thickness0.179 in4.5 mm
tfFlange thickness (average)0.291 in7.4 mm
kDesign value0.75 in19.0 mm
kDetailing value3/4 in19.0 mm
WWeight7 lb/ft10.4 kg/m
AArea2.09 in²1,348 mm²
x̄Centroid from back of web0.501 in12.7 mm
eoShear centre from web0.583 in14.8 mm
IxMoment of inertia, strong axis11.4 in⁴474.5 cm⁴
ZxPlastic modulus, strong axis4.5 in³73.7 cm³
SxSection modulus, strong axis3.81 in³62.4 cm³
rxRadius of gyration, strong axis2.34 in59.4 mm
IyMoment of inertia, weak axis0.603 in⁴25.1 cm⁴
ZyPlastic modulus, weak axis0.865 in³14.2 cm³
SySection modulus, weak axis0.439 in³7.2 cm³
ryRadius of gyration, weak axis0.54 in13.6 mm
JTorsional constant0.046 in⁴1.93 cm⁴
Metric designationMC150×10.4

Also known as

MC150×10.4

Channels of the same depth in the other series

All C & MC Channels (AISC) sizes

Compare all 72 shapes in the C & MC Channels (AISC) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): C and MC shapes
  2. ASTM A6/A6M: dimensions and tolerances of rolled structural shapes

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.