M12 × 1.5 Cable Gland Thread & Hole Size
Cable Glands · Metric M × 1.5 (EN 60423)
A M12 × 1.5 cable gland has a 12 mm (0.472 in) entry thread with 1.5 mm (16.9 TPI) pitch. The table below gives the clearance hole for a gland held by a locknut and the tap drill for a threaded entry.
- dThread outside diameter
- 12 mm0.472 in0.472 in12 mm
- PThread pitch
- 1.5 mm16.9 TPI16.9 TPI1.5 mm
- ⌀Clearance hole
- 12.2–12.5 mm0.480–0.492 in0.480–0.492 in12.2–12.5 mm
- Cable range, example
- 3.5–7 mm0.138–0.276 in0.138–0.276 in3.5–7 mm
Drawing
M12 × 1.5 specifications
| dThread outside diameter | 12 mm0.472 in |
|---|---|
| PThread pitch | 1.5 mm16.9 TPI |
| ⌀Clearance hole | 12.2–12.5 mm0.480–0.492 in |
| Tap drill (threaded entry) | 10.5 mm0.413 in |
| Cable range, example | 3.5–7 mm0.138–0.276 in |
Also known as
M12
All Cable Glands sizes
Sources
- DIN 40430: Steel conduit thread (PG): dimensions, via gewindebohrer.de thread tables
- Heyco: PG hub liquid-tight cordgrip, DIN 40430 thread specifications
- Newman Tools: PG steel conduit taps per DIN 40430 (tap drill sizes)
- LAPP: SKINTOP ST-M cable glands, metric (clamping ranges)
- metric-bolt-torque.com: Cable gland sizes and entry holes
- Greenlee: Standard round knockout punches (hole sizes per conduit trade size)
- ASME B1.20.1: Pipe threads, general purpose (inch), NPT
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.