M20 × 1.5 Cable Gland Thread & Hole Size

Cable Glands · Metric M × 1.5 (EN 60423)

A M20 × 1.5 cable gland has a 20 mm (0.787 in) entry thread with 1.5 mm (16.9 TPI) pitch. The table below gives the clearance hole for a gland held by a locknut and the tap drill for a threaded entry.

dThread outside diameter
20 mm0.787 in0.787 in20 mm
PThread pitch
1.5 mm16.9 TPI16.9 TPI1.5 mm
⌀Clearance hole
20.2–20.5 mm0.795–0.807 in0.795–0.807 in20.2–20.5 mm
Cable range, example
7–13 mm0.276–0.512 in0.276–0.512 in7–13 mm

Drawing

⌀20 mm⌀0.787 inpitch 1.5 mm16.9 TPIhole ⌀20.2–20.5 mmhole ⌀0.795–0.807 incable ⌀7–13 mmcable ⌀0.276–0.512 inenclosure wall
Gland with locknut through an enclosure wall. Thread and hole proportional; body and cap nut shape typical.Proportions shown, not to scale · Dimensions in mmDimensions in inches

M20 × 1.5 specifications

dThread outside diameter20 mm0.787 in
PThread pitch1.5 mm16.9 TPI
⌀Clearance hole20.2–20.5 mm0.795–0.807 in
Tap drill (threaded entry)18.5 mm0.728 in
Cable range, example7–13 mm0.276–0.512 in

The most common size on control panels and junction boxes. The example SKINTOP ST-M M20 takes 7–13 mm cable; reduced-range inserts for 5–9 mm cable are common. M20 replaces PG11 (18.6 mm) and often PG13.5 (20.4 mm), not by thread but by cable range.

Also known as

M20

All Cable Glands sizes

Compare all 24 thread sizes in the Cable Glands chart →

Sources

  1. DIN 40430: Steel conduit thread (PG): dimensions, via gewindebohrer.de thread tables
  2. Heyco: PG hub liquid-tight cordgrip, DIN 40430 thread specifications
  3. Newman Tools: PG steel conduit taps per DIN 40430 (tap drill sizes)
  4. LAPP: SKINTOP ST-M cable glands, metric (clamping ranges)
  5. metric-bolt-torque.com: Cable gland sizes and entry holes
  6. Greenlee: Standard round knockout punches (hole sizes per conduit trade size)
  7. ASME B1.20.1: Pipe threads, general purpose (inch), NPT

Values last checked against these sources on November 15, 2026. · How we check data