LMR-400 Coax Cable Specifications

Coaxial Cable Types · 50 Ω low-loss (LMR)

LMR-400 is a 50 Ω coaxial cable, about 0.405 in (10.29 mm) outside diameter, with a 0.108 in (2.74 mm) copper-clad aluminum center conductor and foam PE dielectric. Velocity factor 85%. Typical use: Low-loss replacement for RG-8/RG-213: antenna feed lines, cellular, ham radio.

Impedance
50 Ω
DOutside diameter
10.29 mm0.405 in0.405 in10.29 mm
Velocity factor
85%

Drawing

⌀10.29 mm⌀0.405 incenter · dielectric · shield · jacket
Center conductor, dielectric, shield and jacket, typical proportions.Drawn to scale · Dimensions in mmDimensions in inches

LMR-400 specifications

Impedance50 Ω
DOutside diameter0.405 in10.29 mm
Center conductor0.108 in (2.74 mm) copper-clad aluminum
Dielectricfoam PE
Velocity factor85%
Shieldfoil + braid
Typical useLow-loss replacement for RG-8/RG-213: antenna feed lines, cellular, ham radio

LMR-400 is the most common low-loss antenna cable: 0.405 in (10.3 mm), the same outside diameter as RG-8 and RG-213, with foam dielectric, bonded foil plus braid and a copper-clad aluminum center (solid copper in the LMR-400-UF "ultraflex" version, which is more flexible but slightly lossier).

Same outside diameter

All Coaxial Cable Types sizes

Compare all 12 sizes in the Coaxial Cable Types chart →

Sources

  1. MIL-DTL-17: Cables, radio frequency, flexible and semirigid (RG slash sheets)
  2. Times Microwave Systems: LMR-195, LMR-240, LMR-400, LMR-600 data sheets
  3. Belden: RG-6, RG-59, RG-11, RG-58, RG-213 coaxial cable catalogue
  4. SCTE 74: Specification for braided 75 Ω flexible RF coaxial drop cable (RG-6/59/11 series)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.