Coaxial Cable Types: RG-6, RG-59, RG-58, RG-213, LMR-400

The first thing to match on any coax is the impedance: 75 Ω cables (RG-6, RG-59, RG-11) are for TV, satellite, CCTV and broadband; 50 Ω cables (RG-58, RG-213, RG-174, LMR) are for radio transmitters, antennas, Wi-Fi, cellular and test equipment. Mixing them causes reflections and loss.

12 cable typesChecked 2026-11-154 sources
RG-3162.5RG-1742.5RG-585.0LMR-1955.0LMR-2406.1RG-596.1RG-66.9RG-810.3RG-21310.3LMR-40010.3RG-1110.5LMR-60015.0OD in mm
Outside diameter (dark) and typical dielectric (light), all at one scale.Drawn to scale

Cable typesTap a type for its cross-section

12 of 12
TypeImpedanceΩDOutside diametermminCenter conductorDielectricVelocity factor%Shield
75 Ω video and broadband (RG)
RG-6/U756.860.27018 AWG (1.02 mm), copper-clad steel or copperfoam PE—foil + braid (dual, tri or quad shield)
RG-59/U756.150.24220–22 AWG (0.81–0.64 mm)solid or foam PE—braid, or foil + braid
RG-11/U7510.460.41214 AWG (1.63 mm)foam PE—foil + braid
50 Ω RF (RG)
RG-58/U504.950.19520 AWG (0.81 mm) solid; 58A/C: strandedsolid PE66braid
RG-8/U5010.290.40513 AWG, 7-strand (about 2.2 mm)solid PE66braid
RG-213/U5010.290.40513 AWG, 7 × 0.0296 in (2.26 mm)solid PE66braid
RG-174/U502.540.10026 AWG, 7-strand (0.48 mm)solid PE66braid
RG-316/U502.490.09826 AWG, 7-strand silver-plated CCS (0.51 mm)PTFE69.5silver-plated braid
50 Ω low-loss (LMR)
LMR-195504.950.1950.037 in (0.94 mm) solid copperfoam PE80foil + braid
LMR-240506.100.2400.056 in (1.42 mm) solid copperfoam PE84foil + braid
LMR-4005010.290.4050.108 in (2.74 mm) copper-clad aluminumfoam PE85foil + braid
LMR-6005014.990.5900.176 in (4.47 mm) copper-clad aluminumfoam PE87foil + braid

What the RG numbers and specs mean

RG stood for "Radio Guide" in the US military MIL-C-17 system. The number is just a catalogue entry; RG-6 is not related to RG-8 by size. Suffixes mark revisions: RG-58/U, RG-58A/U (stranded center), RG-58C/U (non-contaminating jacket). Today the RG names are generic, and products sold as "RG-6" or "RG-59" vary widely in dielectric, shield coverage and center conductor.

Impedance (50 or 75 Ω) is set by the ratio of dielectric diameter to center conductor diameter and the dielectric material. Velocity factor is the speed of the signal in the cable relative to light: 0.66 for solid polyethylene, about 0.75–0.87 for foam PE, about 0.70 for PTFE. Foam dielectric means lower loss; it also means a cable that crushes more easily.

Loss grows with frequency and falls with cable size. For the same impedance and dielectric, a cable twice the diameter has roughly half the loss in dB per meter. At 2.4 GHz a few meters of thin RG-174 or RG-58 can cost more signal than the antenna gains. Use LMR-240 or LMR-400 for anything longer than a short jumper. Check the manufacturer's attenuation table for the actual frequency.

About Coaxial Cable Types

The table gives nominal impedance, outside diameter and the construction of the most common coax types. RG values are typical of MIL-spec and major-brand products; LMR values are from Times Microwave, which owns the LMR name (other makers sell equivalents under names such as "400-series" or "-400").

For TV and satellite use RG-6 with a solid copper or copper-clad steel 18 AWG center and foil-plus-braid shield; satellite LNB power and DiSEqC need a copper center (or a satellite-rated CCS cable) for low DC resistance. RG-59 is thinner with higher loss and is only suitable for short runs and analog CCTV. RG-11 is for long runs over about 50 m.

For radio and antennas RG-58 is the classic thin 50 Ω cable (BNC test leads, short jumpers), RG-213 and RG-8 the thick classic feed lines for HF and VHF, and the LMR series the low-loss replacements of the same outside diameters: LMR-195 for RG-58, LMR-240 for RG-8X, LMR-400 for RG-8/RG-213. Same OD means the same connector bodies often fit, but check the connector's center pin size.

Connectors must match the cable: F connectors for RG-6/59/11 (compression type), BNC for RG-58/59 and test equipment, N and UHF (PL-259) for RG-8/213/LMR-400, SMA for RG-174/316 and LMR-100/195.

Which coax for which job

Typical choices:

JobCableConnector
Cable TV, antenna, satellite (normal runs)RG-6F (compression)
Long TV/satellite runs (> 50 m)RG-11F
Analog CCTV, SDI video (short)RG-59BNC
Test leads, oscilloscope, labRG-58BNC
HF/VHF transmitter feed lineRG-213 or LMR-400N, UHF (PL-259)
Wi-Fi / cellular antenna lead, 1–5 mLMR-240 or LMR-195N, SMA, RP-SMA, TNC
Internal pigtails, GPS modulesRG-174, RG-316SMA, U.FL/IPEX, MCX

Questions

What is the difference between RG-6 and RG-59?

Both are 75 Ω. RG-6 is thicker (about 6.9 mm vs 6.1 mm), has an 18 AWG center (vs 20–22 AWG) and usually foil plus braid shielding, so it has lower loss at the GHz frequencies of satellite and cable TV. RG-59 is for short runs and analog video.

Can I use 75 Ω cable for a 50 Ω radio?

Only as a compromise for receiving. For transmitting, a 75 Ω cable on a 50 Ω system gives a 1.5:1 mismatch (SWR) before the antenna is even considered. Use 50 Ω cable (RG-58, RG-213, LMR) with 50 Ω equipment.

What coax is equivalent to LMR-400?

In size, RG-8 and RG-213 (both 0.405 in). In loss, LMR-400 is clearly better than both because of its foam dielectric. Third-party equivalents are sold as "400-series" or "-400" low-loss cable.

What does velocity factor mean?

The fraction of the speed of light at which the signal travels in the cable. With VF 0.66 a wavelength in the cable is 66 % of the free-space wavelength, which matters when cutting quarter-wave stubs or matching sections.

Which coax for an outdoor TV antenna?

RG-6 with a UV-resistant jacket (or direct-burial RG-6 with flooding compound for underground runs), and compression F connectors with weather boots.

Sources

  1. MIL-DTL-17: Cables, radio frequency, flexible and semirigid (RG slash sheets)
  2. Times Microwave Systems: LMR-195, LMR-240, LMR-400, LMR-600 data sheets
  3. Belden: RG-6, RG-59, RG-11, RG-58, RG-213 coaxial cable catalogue
  4. SCTE 74: Specification for braided 75 Ω flexible RF coaxial drop cable (RG-6/59/11 series)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.