PG7 Cable Gland Thread & Hole Size

Cable Glands · PG: steel conduit thread (DIN 40430)

A PG7 cable gland has a 12.5 mm (0.492 in) entry thread with 1.27 mm (20.0 TPI) pitch. The table below gives the clearance hole for a gland held by a locknut and the tap drill for a threaded entry.

dThread outside diameter
12.5 mm0.492 in0.492 in12.5 mm
PThread pitch
1.27 mm20.0 TPI20.0 TPI1.27 mm
⌀Clearance hole
12.7–13 mm0.500–0.512 in0.500–0.512 in12.7–13 mm

Drawing

⌀12.5 mm⌀0.492 inpitch 1.27 mm20.0 TPIhole ⌀12.7–13 mmhole ⌀0.500–0.512 inenclosure wall
Gland with locknut through an enclosure wall. Thread and hole proportional; body and cap nut shape typical.Proportions shown, not to scale · Dimensions in mmDimensions in inches

PG7 specifications

dThread outside diameter12.5 mm0.492 in
PThread pitch1.27 mm20.0 TPI
⌀Clearance hole12.7–13 mm0.500–0.512 in
Tap drill (threaded entry)11.4 mm0.449 in

PG7 is 12.5 mm with 20 threads per inch (1.27 mm pitch), the usual entry on small sensors and solenoid valves. The metric successor is M12 × 1.5.

All Cable Glands sizes

Compare all 24 thread sizes in the Cable Glands chart →

Sources

  1. DIN 40430: Steel conduit thread (PG): dimensions, via gewindebohrer.de thread tables
  2. Heyco: PG hub liquid-tight cordgrip, DIN 40430 thread specifications
  3. Newman Tools: PG steel conduit taps per DIN 40430 (tap drill sizes)
  4. LAPP: SKINTOP ST-M cable glands, metric (clamping ranges)
  5. metric-bolt-torque.com: Cable gland sizes and entry holes
  6. Greenlee: Standard round knockout punches (hole sizes per conduit trade size)
  7. ASME B1.20.1: Pipe threads, general purpose (inch), NPT

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.