100×50×10 PFC Channel Dimensions & Properties
Channels (UPN, UPE, PFC, JIS) · PFC: British parallel flange channels (BS 4-1)
100×50×10 PFC (PFC: British parallel flange channels, BS 4-1) is 100 mm (3.937 in) deep with a 50 mm (1.969 in) flange, a 5 mm (0.197 in) web and a 8.5 mm (0.335 in) flange. Mass 10.2 kg/m (6.854 lb/ft), area 13 cm² (2.015 in²); strong-axis I = 208 cm⁴ (5 in⁴), Wel = 41.5 cm³ (2.53 in³).
- hDepth
- 100 mm3.937 in3.937 in100 mm
- bFlange width
- 50 mm1.969 in1.969 in50 mm
- twWeb thickness
- 5 mm0.197 in0.197 in5 mm
- tfFlange thickness
- 8.5 mm0.335 in0.335 in8.5 mm
Drawing
100×50×10 PFC specifications
| hDepth | 100 mm3.937 in |
|---|---|
| bFlange width | 50 mm1.969 in |
| twWeb thickness | 5 mm0.197 in |
| tfFlange thickness | 8.5 mm0.335 in |
| r1Root radius | 9 mm0.354 in |
| GMass | 10.2 kg/m6.854 lb/ft |
| AArea | 13 cm²2.015 in² |
| eCentroid from back of web | 1.73 cm0.681 in |
| IyMoment of inertia, strong axis | 208 cm⁴5 in⁴ |
| Wel,yElastic modulus, strong axis | 41.5 cm³2.53 in³ |
| Wpl,yPlastic modulus, strong axis | 48.9 cm³2.98 in³ |
| iyRadius of gyration, strong axis | 4 cm1.575 in |
| IzMoment of inertia, weak axis | 32.3 cm⁴0.78 in⁴ |
| Wel,zElastic modulus, weak axis | 9.89 cm³0.6 in³ |
| izRadius of gyration, weak axis | 1.58 cm0.622 in |
Also known as
PFC100x50x10
Channels of about the same depth in other series
All Channels (UPN, UPE, PFC, JIS) sizes
Compare all 58 sections in the Channels (UPN, UPE, PFC, JIS) chart →
Sources
- EN 10279:2000, Hot rolled steel channels. Tolerances on shape, dimension and mass
- EN 10365:2017, Hot rolled steel channels, I and H sections. Dimensions and masses
- ArcelorMittal: Sections and Merchant Bars sales programme, UPN and UPE tables
- SCI / BCSA: Steel Building Design: Design Data (Blue Book), parallel flange channels
- JIS G 3192:2024 and JFE Steel building steel handbook, channel section table
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.