UPN 100 Channel Dimensions & Properties

Channels (UPN, UPE, PFC, JIS) · UPN: European standard channels, tapered flanges (EN 10279, DIN 1026-1)

UPN 100 (UPN: European standard channels, tapered flanges, EN 10279, DIN 1026-1) is 100 mm (3.937 in) deep with a 50 mm (1.969 in) flange, a 6 mm (0.236 in) web and a 8.5 mm (0.335 in) flange. Mass 10.6 kg/m (7.123 lb/ft), area 13.5 cm² (2.093 in²); strong-axis I = 206 cm⁴ (4.95 in⁴), Wel = 41.2 cm³ (2.51 in³).

hDepth
100 mm3.937 in3.937 in100 mm
bFlange width
50 mm1.969 in1.969 in50 mm
twWeb thickness
6 mm0.236 in0.236 in6 mm
tfFlange thickness
8.5 mm0.335 in0.335 in8.5 mm

Drawing

50 mm1.969 in100 mm3.937 intf 8.5 mmtf 0.335 intw 6 mmtw 0.236 inr1 8.5 mmr1 0.335 in
Drawn to scale · Dimensions in mmDimensions in inches

UPN 100 specifications

hDepth100 mm3.937 in
bFlange width50 mm1.969 in
twWeb thickness6 mm0.236 in
tfFlange thickness8.5 mm0.335 in
r1Root radius8.5 mm0.335 in
r2Toe radius4.5 mm0.177 in
GMass10.6 kg/m7.123 lb/ft
AArea13.5 cm²2.093 in²
IyMoment of inertia, strong axis206 cm⁴4.95 in⁴
Wel,yElastic modulus, strong axis41.2 cm³2.51 in³
Wpl,yPlastic modulus, strong axis49 cm³2.99 in³
iyRadius of gyration, strong axis3.91 cm1.539 in
IzMoment of inertia, weak axis29.3 cm⁴0.7 in⁴
Wel,zElastic modulus, weak axis8 cm³0.49 in³
izRadius of gyration, weak axis1.47 cm0.579 in

Also known as

U100UNP100

Channels of about the same depth in other series

All Channels (UPN, UPE, PFC, JIS) sizes

Compare all 58 sections in the Channels (UPN, UPE, PFC, JIS) chart →

Sources

  1. EN 10279:2000, Hot rolled steel channels. Tolerances on shape, dimension and mass
  2. EN 10365:2017, Hot rolled steel channels, I and H sections. Dimensions and masses
  3. ArcelorMittal: Sections and Merchant Bars sales programme, UPN and UPE tables
  4. SCI / BCSA: Steel Building Design: Design Data (Blue Book), parallel flange channels
  5. JIS G 3192:2024 and JFE Steel building steel handbook, channel section table

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.