UPN 160 Channel Dimensions & Properties
Channels (UPN, UPE, PFC, JIS) · UPN: European standard channels, tapered flanges (EN 10279, DIN 1026-1)
UPN 160 (UPN: European standard channels, tapered flanges, EN 10279, DIN 1026-1) is 160 mm (6.299 in) deep with a 65 mm (2.559 in) flange, a 7.5 mm (0.295 in) web and a 10.5 mm (0.413 in) flange. Mass 18.8 kg/m (12.633 lb/ft), area 24 cm² (3.720 in²); strong-axis I = 925 cm⁴ (22.22 in⁴), Wel = 116 cm³ (7.08 in³).
- hDepth
- 160 mm6.299 in6.299 in160 mm
- bFlange width
- 65 mm2.559 in2.559 in65 mm
- twWeb thickness
- 7.5 mm0.295 in0.295 in7.5 mm
- tfFlange thickness
- 10.5 mm0.413 in0.413 in10.5 mm
Drawing
UPN 160 specifications
| hDepth | 160 mm6.299 in |
|---|---|
| bFlange width | 65 mm2.559 in |
| twWeb thickness | 7.5 mm0.295 in |
| tfFlange thickness | 10.5 mm0.413 in |
| r1Root radius | 10.5 mm0.413 in |
| r2Toe radius | 5.5 mm0.217 in |
| GMass | 18.8 kg/m12.633 lb/ft |
| AArea | 24 cm²3.720 in² |
| IyMoment of inertia, strong axis | 925 cm⁴22.22 in⁴ |
| Wel,yElastic modulus, strong axis | 116 cm³7.08 in³ |
| Wpl,yPlastic modulus, strong axis | 138 cm³8.42 in³ |
| iyRadius of gyration, strong axis | 6.21 cm2.445 in |
| IzMoment of inertia, weak axis | 85.3 cm⁴2.05 in⁴ |
| Wel,zElastic modulus, weak axis | 18 cm³1.1 in³ |
| izRadius of gyration, weak axis | 1.89 cm0.744 in |
Also known as
U160UNP160
Channels of about the same depth in other series
All Channels (UPN, UPE, PFC, JIS) sizes
Compare all 58 sections in the Channels (UPN, UPE, PFC, JIS) chart →
Sources
- EN 10279:2000, Hot rolled steel channels. Tolerances on shape, dimension and mass
- EN 10365:2017, Hot rolled steel channels, I and H sections. Dimensions and masses
- ArcelorMittal: Sections and Merchant Bars sales programme, UPN and UPE tables
- SCI / BCSA: Steel Building Design: Design Data (Blue Book), parallel flange channels
- JIS G 3192:2024 and JFE Steel building steel handbook, channel section table
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.