Stair Dimensions by Code: Riser, Tread, Headroom, Handrail

Code limits for stair geometry and a calculator that turns a floor-to-floor height into risers and treads. US homes (IRC) allow a riser of up to 7-3/4 in with a tread of at least 10 in; commercial stairs (IBC) 7 in and 11 in.

13 sizesChecked 2026-11-156 sources
IRC197 / 254 mm · 38°IBC178 / 279 mm · 32°UK private stair220 / 220 mm · 45°DIN 18065200 / 230 mm · 41°Korea apt.180 / 260 mm · 35°Japan home230 / 150 mm · 57°
Maximum rise with minimum going for each rule, three steps at one scale; figures are rise / going and pitch. England also caps the pitch at 42°, so 220/220 mm is not allowed together.Drawn to scale · Dimensions in mmDimensions in inches

Size chartSort by any column, or filter to find a row

13 of 13
Code / stair typeRRiser heightmminmm · inGTread / goingmminmm · inWMinimum widthmminmm · inHRMinimum headroommminmm · inHHHandrail heightmminmm · inRule
United States (IRC / IBC 2021)
IRC (dwellings)1977 3/42541091436203280864–96534–38IRC R311.7
IBC (commercial and public)102–1784–727911111844203280864–96534–38IBC 1011
England (Approved Document K)
UK private stair150–2205.91–8.66220–3008.66–11.81—200078.74900–100035.43–39.37Approved Document K
UK utility stair150–1905.91–7.48250–4009.84–15.75—200078.74900–100035.43–39.37Approved Document K
UK general access stair150–1705.91–6.69250–4009.84–15.75—200078.74900–100035.43–39.37Approved Document K
Germany (DIN 18065)
Germany (homes with ≤ 2 dwellings)140–2005.51–7.87230–3709.06–14.5780031.5200078.74—DIN 18065
Germany (other buildings)140–1905.51–7.48260–37010.24–14.57100039.37200078.74—DIN 18065
Korea
Korea (apartment common stairs)1807.0926010.24120047.24——주택건설기준 제16조
Korea (elementary school)1606.326010.24150059.06——피난·방화규칙 제15조
Korea (middle and high school)1807.0926010.24150059.06——피난·방화규칙 제15조
Japan (Building Standard Law)
Japan (dwellings)2309.061505.9175029.53——施行令 第23条
Japan (elementary school)1606.326010.24140055.12——施行令 第23条
Japan (other buildings)2208.662108.2775029.53——施行令 第23条

Rise, going and the step rule

A single value in the chart is a maximum riser or minimum going; a range gives the permitted minimum–maximum. Rise (riser height) is measured vertically from tread surface to tread surface; going (run, tread depth) horizontally from nosing to nosing. This is not the tread board width, which is larger by the nosing.

All risers in a flight must be equal: the IRC allows 3/8 in difference between the largest and smallest riser or tread; DIN and Part K expect constant values within the flight.

A stair is comfortable when 2R + G ≈ 25 in (630 mm), the average stride. Part K requires 550–700 mm; DIN 18065 gives 590–650 mm. A 7-in rise with an 11-in tread gives 25 in.

Headroom is measured vertically from the sloped line through the nosings to the ceiling or beam above.

About Stair Dimensions

To design a stair, divide the floor-to-floor height (finished floor to finished floor) by the maximum riser and round up to get the number of risers. The number of treads is one less, because the top floor serves as the last step.

Example (IRC): 108 in floor to floor ÷ 7-3/4 in = 13.9 → 14 risers of 7.71 in, 13 treads of 10 in = 130 in total run.

Nosings: the IRC requires a 3/4 to 1-1/4 in nosing when the tread is less than 11 in. Open risers must not let a 4-in sphere pass in IRC stairs (guard rule).

Codes also cap the height of a single flight: 151 in (12 ft 7 in) under the IRC and 12 ft (3.66 m) under the IBC before a landing is needed; Part K limits a flight to 16 risers in utility and general access stairs.

Handrails and guards

RuleHandrail heightGuard heightNote
IRC34–38 in36 in (where drop > 30 in)Rail required with 4 or more risers
IBC34–38 in42 inRails on both sides
UK Part K900–1000 mm900 mm (private stair)Rail both sides if 1 m wide or more

Questions

What is the maximum stair riser height?

7-3/4 in (197 mm) in US homes under the IRC; 7 in (178 mm) under the IBC; 220 mm for a private stair in England; 200 mm in German homes (DIN 18065); 230 mm in Japanese homes.

What is the minimum stair tread depth?

10 in (254 mm) under the IRC, 11 in (279 mm) under the IBC, 220 mm for private stairs in England, 230 mm in German homes.

What is the minimum headroom for stairs?

6 ft 8 in (2032 mm) under the IRC and 80 in under the IBC; 2.0 m in England and Germany.

How high should a stair handrail be?

34 to 38 in above the nosing line in the US (IRC and IBC); 900–1000 mm in England.

What is the 2R+T rule?

Twice the riser plus the tread should be about 25 in (630 mm). England requires 550–700 mm, DIN 18065 gives 590–650 mm.

Sources

  1. ICC: International Residential Code 2021, R311.7 Stairways
  2. ICC: International Building Code 2021, §1011 Stairways and §1014 Handrails
  3. HM Government: Approved Document K: Protection from falling, collision and impact (Table 1.1)
  4. DIN 18065:2020-08, Gebäudetreppen, Begriffe, Messregeln, Hauptmaße
  5. 건축물의 피난·방화구조 등의 기준에 관한 규칙 제15조; 주택건설기준 등에 관한 규정 제16조 (국가법령정보센터)
  6. 建築基準法施行令 第23条 (e-Gov 法令検索); 国土交通省 技術的助言

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.