Standard Door Sizes: Interior, Exterior, Garage, UK and DIN

Standard door leaf sizes and the wall openings they need. US doors are 80 in (6'8") tall and come in 2-in width steps; an interior prehung door needs a rough opening of door width + 2 in by 82-1/2 in.

47 sizesChecked 2026-11-157 sources

Size chartTap a size for its drawing and full specs

47 of 47
DoorWDoor widthmminmm · inHDoor heightmminmm · intThicknessmminmm · inRWRough / wall opening widthmminmm · inRHRough / wall opening heightmminmm · inTrade code (ft-in)
US interior doors (prehung, 1-3/8 in)
18 × 80 in4571820328034.91 3/8508202095.582 1/21668
24 × 80 in6102420328034.91 3/8660.4262095.582 1/22068
28 × 80 in7112820328034.91 3/8762302095.582 1/22468
30 × 80 in7623020328034.91 3/8812.8322095.582 1/22668
32 × 80 in8133220328034.91 3/8863.6342095.582 1/22868
36 × 80 in9143620328034.91 3/8965.2382095.582 1/23068
30 × 96 in7623024389634.91 3/8812.8322501.998 1/22680
32 × 96 in8133224389634.91 3/8863.6342501.998 1/22880
36 × 96 in9143624389634.91 3/8965.2382501.998 1/23080
US exterior, double and patio doors
32 × 80 in8133220328044.51 3/4———
34 × 80 in8643420328044.51 3/4———
36 × 80 in9143620328044.51 3/4———
36 × 96 in9143624389644.51 3/4———
60 × 80 in double15246020328044.51 3/4———
72 × 80 in double18297220328044.51 3/4———
60 × 80 in patio15246020328044.51 3/4———
72 × 80 in patio18297220328044.51 3/4———
US garage doors
8 × 7 ft garage243896213484———8 ft × 7 ft
9 × 7 ft garage2743108213484———9 ft × 7 ft
9 × 8 ft garage2743108243896———9 ft × 8 ft
10 × 7 ft garage3048120213484———10 ft × 7 ft
10 × 8 ft garage3048120243896———10 ft × 8 ft
16 × 7 ft garage4877192213484———16 ft × 7 ft
16 × 8 ft garage4877192243896———16 ft × 8 ft
18 × 7 ft garage5486216213484———18 ft × 7 ft
UK door leaves
1981 × 610 mm61024.016198177.992351.378———
1981 × 686 mm68627.008198177.992351.378———
1981 × 711 mm71127.992198177.992351.378———
1981 × 762 mm76230198177.992351.378———
1981 × 838 mm83832.992198177.992351.378———
2040 × 526 mm52620.709204080.315401.575———
2040 × 626 mm62624.646204080.315401.575———
2040 × 726 mm72628.583204080.315401.575———
2040 × 826 mm82632.52204080.315401.575———
2040 × 926 mm92636.457204080.315401.575———
1981 × 762 mm external76230198177.992441.732———
1981 × 838 mm external83832.992198177.992441.732———
2032 × 813 mm external81332.008203280441.732———
Germany: DIN 18101
625 × 2000 (DIN 18101)61024.016198578.15—62524.606200078.74—
750 × 2000 (DIN 18101)73528.937198578.15—75029.528200078.74—
875 × 2000 (DIN 18101)86033.858198578.15—87534.449200078.74—
1000 × 2000 (DIN 18101)98538.78198578.15—100039.37200078.74—
1125 × 2000 (DIN 18101)111043.701198578.15—112544.291200078.74—
750 × 2125 (DIN 18101)73528.937211083.071—75029.528212583.661—
875 × 2125 (DIN 18101)86033.858211083.071—87534.449212583.661—
1000 × 2125 (DIN 18101)98538.78211083.071—100039.37212583.661—
1125 × 2125 (DIN 18101)111043.701211083.071—112544.291212583.661—

How door sizes are named

US doors are sold by width × height of the slab in inches, or as a four-digit feet-and-inches code: 2868 = 2'8" × 6'8" = 32 × 80 in; 3068 = 36 × 80 in. Width always comes first.

The rough opening is the framed hole. For an interior prehung unit allow the door width + 2 in and the door height + 2-1/2 in (82-1/2 in for 80-in doors): that leaves room for the jambs, shims and a gap over the finished floor. Exterior units with thicker frames and sills have their own rough-opening figure; read it off the maker's sheet.

In Germany, DIN 18101 links the wall opening to the leaf: an 875 × 2000 mm opening (Baurichtmaß) takes an 860 × 1985 mm rebated leaf. UK leaves are sold by height × width in mm: 1981 × 762 is the imperial 6'6" × 2'6"; metric leaves are 2040 mm high and 40 mm thick.

About Door Sizes

To replace a slab, measure the existing door, not the opening: width, height and thickness, plus hinge positions. To replace a prehung unit, measure the rough opening after removing the casing.

Clear width is what counts for codes and wheelchairs: it is measured with the door open 90°, between the face of the door and the stop, so it is about 2 in less than the leaf. A 36-in door gives roughly 34 in clear; ADA and the IRC egress door need at least 32 in clear.

Common rules of thumb: bathrooms and closets use 24–30-in doors, bedrooms 30–32 in, the main entry 36 in. Taller 8-ft doors (96 in) are common with 9- and 10-ft ceilings.

Garage doors are named in feet (16 × 7 = 16 ft wide, 7 ft high). The rough opening equals the door size; the door overlaps the jambs and needs headroom above the opening for the track (about 12 in or more for standard torsion springs).

Code minimums (US)

Model codes set minimum clear openings, not leaf sizes. Check the edition adopted locally.

RequirementValueSource
Egress door clear width32 in minIRC R311.2
Egress door clear height78 in minIRC R311.2
Accessible door clear width32 in min (open 90°)ADA 2010 §404.2.3
Maneuvering clearance, pull side (front approach)18 in beside latchADA 2010 §404.2.4

Questions

What is the standard interior door size?

80 in (6'8") high; widths 24, 28, 30, 32 and 36 in. 30 and 32 in are typical for bedrooms, 36 in for the widest passage.

What is the rough opening for a 32 x 80 door?

34 × 82-1/2 in for a prehung interior unit (door width + 2 in, height + 2-1/2 in). Some makers specify 82 in; check the unit's sheet.

What is the standard front door size?

36 × 80 in and 1-3/4 in thick. 32 and 34-in exterior doors exist for side and back entries; 8-ft (96-in) doors suit tall ceilings.

What are standard garage door sizes?

Single: 8 × 7, 9 × 7, 9 × 8 or 10 × 8 ft. Double: 16 × 7, 16 × 8 or 18 × 7 ft.

What size is a standard UK internal door?

1981 × 762 × 35 mm (6'6" × 2'6"). Metric doors are 2040 mm high and 40 mm thick: 626, 726, 826 or 926 mm wide.

What door sizes does DIN 18101 specify?

Wall openings of 625, 750, 875, 1000 or 1125 mm × 2000 or 2125 mm, with leaves 15 mm smaller each way: 875 × 2000 opening → 860 × 1985 mm leaf.

Sources

  1. IRC 2021 R311.2: Egress door (32 in clear width, 78 in clear height)
  2. 2010 ADA Standards for Accessible Design §404.2.3: door clear width 32 in min.
  3. Metrie: How to measure prehung interior doors (rough opening = door + 2 in width, + 2-1/2 in height)
  4. Howarth Timber: UK door sizes (imperial 1981 mm and metric 2040 mm leaves)
  5. Wikipedia (de): Tür, Türblatt- und Zargenmaße nach DIN 18101
  6. Clopay: What are the standard garage door sizes
  7. DIN 18101: Türen für den Wohnungsbau: Türblattgrößen, Bandsitz und Schlosssitz (Baunetz Wissen summary)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.