Bathroom Fixture Dimensions and Clearances
Code clearances and stock sizes for planning a bathroom. A toilet needs 15 in from its centreline to a side wall, 30 in centre to centre to the next fixture and 21 in of clear floor in front; the standard rough-in is 12 in.
Size chartSort by any column, or filter to find a row
| Dimension | ADimensionmminmm · in | BSecond dimensionmminmm · in | Type of value | Rule / source |
|---|---|---|---|---|
| Toilets: rough-in and IPC/IRC clearances | ||||
| Toilet rough-in, standard | 30512 | — | Standard size | US practice |
| Toilet rough-in, 10 in | 25410 | — | Alternative size | US practice |
| Toilet rough-in, 14 in | 35614 | — | Alternative size | US practice |
| Toilet centre to side wall | 38115 | — | Minimum | IPC 405.3.1 · IRC P2705.1 |
| Toilet centre to adjacent fixture | 76230 | — | Minimum | IPC 405.3.1 · IRC P2705.1 |
| Clear space in front of toilet | 53321 | — | Minimum | IPC 405.3.1 · IRC P2705.1 |
| Lavatories | ||||
| Clear space in front of lavatory | 53321 | — | Minimum | IPC 405.3.1 · IRC P2705.1 |
| Showers and bathtubs | ||||
| Shower, minimum size | 76230 | 76230 | Minimum | IPC 417.4 · IRC P2708.1 (≥ 900 in²) |
| Shower door opening | 55922 | — | Minimum | IRC P2708.1 |
| Alcove bathtub 60 × 30 | 152460 | 76230 | Standard size | US stock |
| Alcove bathtub 60 × 32 | 152460 | 81332 | Standard size | US stock |
| Accessible (2010 ADA Standards) | ||||
| ADA toilet centreline to side wall | 406–45716–18 | — | Required range | ADA 604.2 |
| ADA toilet seat height | 432–48317–19 | — | Required range | ADA 604.4 |
| ADA clearance around toilet | 152460 | 142256 | Minimum | ADA 604.3.1 |
| ADA side grab bar length | 106742 | — | Minimum | ADA 604.5.1 (33–36 in high) |
| ADA rear grab bar length | 91436 | — | Minimum | ADA 604.5.2 (33–36 in high) |
| ADA lavatory rim height | 86434 | — | Maximum | ADA 606.3 |
| ADA knee clearance under lavatory | 68627 | — | Minimum | ADA 306.3 |
| ADA mirror bottom over lavatory | 101640 | — | Maximum | ADA 603.3 |
| ADA transfer shower | 91436 | 91436 | Required size | ADA 608.2.1 |
| ADA roll-in shower | 152460 | 76230 | Minimum | ADA 608.2.2 |
| European stock sizes (mm) | ||||
| Shower tray 800 × 800 | 80031.5 | 80031.5 | Standard size | EU / UK stock |
| Shower tray 900 × 900 | 90035.43 | 90035.43 | Standard size | EU / UK stock |
| Shower tray 1000 × 1000 | 100039.37 | 100039.37 | Standard size | EU / UK stock |
| Shower tray 1000 × 800 | 100039.37 | 80031.5 | Standard size | EU / UK stock |
| Shower tray 1200 × 800 | 120047.24 | 80031.5 | Standard size | EU / UK stock |
| Shower tray 1200 × 900 | 120047.24 | 90035.43 | Standard size | EU / UK stock |
| Shower tray 1400 × 900 | 140055.12 | 90035.43 | Standard size | EU / UK stock |
| Bath 1700 × 700 | 170066.93 | 70027.56 | Standard size | EU / UK stock |
No exact match. The nearest sizes:
Rough-in and clearances
Rough-in is the distance from the finished wall (not the baseboard) to the centre of the closet-flange bolts. Measure it before buying a toilet: 12 in is standard; 10 in and 14 in bowls exist for older or tight bathrooms.
Side clearance is measured from the toilet centreline to the wall, partition or vanity edge: at least 15 in under the IPC and IRC, so a toilet needs a 30-in wide space. Front clearance is clear floor from the front of the bowl: 21 in (24 in is a common design target).
Accessible toilets (ADA) sit 16–18 in from the side wall with the seat at 17–19 in, in a clear space at least 60 in wide and 56 in deep.
About Bathroom Fixture Sizes
Showers need at least 900 in² of floor inside the walls and must fit a 30-in circle (so 30 × 30 in is the smallest square shower); 36 × 36 in is far more usable. The IRC asks for a 22-in clear door opening.
Alcove bathtubs are 60 in long (5 ft) to fit between studs of a 5-ft bathroom; 30 or 32 in wide. In Europe and the UK the stock bath is 1700 × 700 mm, with 1600, 1750 and 1800 mm lengths common.
Lavatory (sink) heights: about 31–32 in for traditional vanities, 34-1/2–36 in for comfort-height; an accessible lavatory rim may be no higher than 34 in, with at least 27 in of knee clearance.
Grab bars for an accessible toilet: side wall at least 42 in long, rear wall at least 36 in, both 33–36 in above the floor to the top of the gripping surface. Plan blocking in the wall before drywall.
Questions
What is the standard toilet rough-in?
12 in from the finished wall to the centre of the floor bolts. 10 in and 14 in rough-in toilets are available for older houses.
How much space do you need beside a toilet?
At least 15 in from the toilet centreline to any side wall or obstruction and 30 in centre to centre to another fixture (IPC/IRC). 21 in clear in front.
What is the ADA toilet height?
17 to 19 in to the top of the seat, with the centreline 16 to 18 in from the side wall.
What is the minimum shower size?
900 in² of floor area, large enough to hold a 30-in circle: 30 × 30 in minimum under the IPC and IRC.
What is the standard bathtub size?
60 × 30 in or 60 × 32 in for US alcove tubs; 1700 × 700 mm in Europe and the UK.
Sources
- ICC: International Plumbing Code 2021, §405.3.1 fixture clearances, §417.4 shower size
- ICC: International Residential Code 2021, P2705.1 and P2708.1
- US DOJ: 2010 ADA Standards for Accessible Design, §§ 306, 603, 604, 606, 608
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.