Bathroom Fixture Dimensions and Clearances

Code clearances and stock sizes for planning a bathroom. A toilet needs 15 in from its centreline to a side wall, 30 in centre to centre to the next fixture and 21 in of clear floor in front; the standard rough-in is 12 in.

29 sizesChecked 2026-11-153 sources
381 mm15 in533 mm21 in305 mm12 in
Plan to scale: 15 in from centreline to side wall, 21 in clear in front (dashed area), 12 in rough-in from the finished wall. Toilet outline typical.Drawn to scale · Dimensions in mmDimensions in inches

Size chartSort by any column, or filter to find a row

29 of 29
DimensionADimensionmminmm · inBSecond dimensionmminmm · inType of valueRule / source
Toilets: rough-in and IPC/IRC clearances
Toilet rough-in, standard30512—Standard sizeUS practice
Toilet rough-in, 10 in25410—Alternative sizeUS practice
Toilet rough-in, 14 in35614—Alternative sizeUS practice
Toilet centre to side wall38115—MinimumIPC 405.3.1 · IRC P2705.1
Toilet centre to adjacent fixture76230—MinimumIPC 405.3.1 · IRC P2705.1
Clear space in front of toilet53321—MinimumIPC 405.3.1 · IRC P2705.1
Lavatories
Clear space in front of lavatory53321—MinimumIPC 405.3.1 · IRC P2705.1
Showers and bathtubs
Shower, minimum size7623076230MinimumIPC 417.4 · IRC P2708.1 (≥ 900 in²)
Shower door opening55922—MinimumIRC P2708.1
Alcove bathtub 60 × 3015246076230Standard sizeUS stock
Alcove bathtub 60 × 3215246081332Standard sizeUS stock
Accessible (2010 ADA Standards)
ADA toilet centreline to side wall406–45716–18—Required rangeADA 604.2
ADA toilet seat height432–48317–19—Required rangeADA 604.4
ADA clearance around toilet152460142256MinimumADA 604.3.1
ADA side grab bar length106742—MinimumADA 604.5.1 (33–36 in high)
ADA rear grab bar length91436—MinimumADA 604.5.2 (33–36 in high)
ADA lavatory rim height86434—MaximumADA 606.3
ADA knee clearance under lavatory68627—MinimumADA 306.3
ADA mirror bottom over lavatory101640—MaximumADA 603.3
ADA transfer shower9143691436Required sizeADA 608.2.1
ADA roll-in shower15246076230MinimumADA 608.2.2
European stock sizes (mm)
Shower tray 800 × 80080031.580031.5Standard sizeEU / UK stock
Shower tray 900 × 90090035.4390035.43Standard sizeEU / UK stock
Shower tray 1000 × 1000100039.37100039.37Standard sizeEU / UK stock
Shower tray 1000 × 800100039.3780031.5Standard sizeEU / UK stock
Shower tray 1200 × 800120047.2480031.5Standard sizeEU / UK stock
Shower tray 1200 × 900120047.2490035.43Standard sizeEU / UK stock
Shower tray 1400 × 900140055.1290035.43Standard sizeEU / UK stock
Bath 1700 × 700170066.9370027.56Standard sizeEU / UK stock

Rough-in and clearances

Rough-in is the distance from the finished wall (not the baseboard) to the centre of the closet-flange bolts. Measure it before buying a toilet: 12 in is standard; 10 in and 14 in bowls exist for older or tight bathrooms.

Side clearance is measured from the toilet centreline to the wall, partition or vanity edge: at least 15 in under the IPC and IRC, so a toilet needs a 30-in wide space. Front clearance is clear floor from the front of the bowl: 21 in (24 in is a common design target).

Accessible toilets (ADA) sit 16–18 in from the side wall with the seat at 17–19 in, in a clear space at least 60 in wide and 56 in deep.

About Bathroom Fixture Sizes

Showers need at least 900 in² of floor inside the walls and must fit a 30-in circle (so 30 × 30 in is the smallest square shower); 36 × 36 in is far more usable. The IRC asks for a 22-in clear door opening.

Alcove bathtubs are 60 in long (5 ft) to fit between studs of a 5-ft bathroom; 30 or 32 in wide. In Europe and the UK the stock bath is 1700 × 700 mm, with 1600, 1750 and 1800 mm lengths common.

Lavatory (sink) heights: about 31–32 in for traditional vanities, 34-1/2–36 in for comfort-height; an accessible lavatory rim may be no higher than 34 in, with at least 27 in of knee clearance.

Grab bars for an accessible toilet: side wall at least 42 in long, rear wall at least 36 in, both 33–36 in above the floor to the top of the gripping surface. Plan blocking in the wall before drywall.

Questions

What is the standard toilet rough-in?

12 in from the finished wall to the centre of the floor bolts. 10 in and 14 in rough-in toilets are available for older houses.

How much space do you need beside a toilet?

At least 15 in from the toilet centreline to any side wall or obstruction and 30 in centre to centre to another fixture (IPC/IRC). 21 in clear in front.

What is the ADA toilet height?

17 to 19 in to the top of the seat, with the centreline 16 to 18 in from the side wall.

What is the minimum shower size?

900 in² of floor area, large enough to hold a 30-in circle: 30 × 30 in minimum under the IPC and IRC.

What is the standard bathtub size?

60 × 30 in or 60 × 32 in for US alcove tubs; 1700 × 700 mm in Europe and the UK.

Sources

  1. ICC: International Plumbing Code 2021, §405.3.1 fixture clearances, §417.4 shower size
  2. ICC: International Residential Code 2021, P2705.1 and P2708.1
  3. US DOJ: 2010 ADA Standards for Accessible Design, §§ 306, 603, 604, 606, 608

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.