PVC Pipe Size Chart: Schedule 40 & 80 OD, Wall, Pressure

Outside diameter, wall, bore and pressure rating of PVC pipe. The nominal size is not a real dimension. 1/2-in PVC is 0.840 in (21.3 mm) OD, the same OD as steel pipe; Schedule 80 keeps the OD and thickens the wall inward.

35 sizesChecked 2026-11-155 sources
1/2"1"2"4"
1/2, 1, 2 and 4 in PVC to scale: filled = Schedule 40 wall; dashed circle = Schedule 80 bore.Drawn to scale · Dimensions in mmDimensions in inches

Size chartSort by any column, or filter to find a row

35 of 35
SizeODOutside diametermminmm · intWall, Sch 40 (min.)mminmm · inIDInside diameter, Sch 40mminmm · inPressure rating Sch 40 (73 °F)barpsibar · psitWall, Sch 80 (min.)mminmm · inIDInside diameter, Sch 80mminmm · inPressure rating Sch 80 (73 °F)barpsibar · psitWall, SDR 26mminmm · intWall, SDR 17mminmm · in
US: ASTM D1785 Schedule 40 / 80 (NPS sizes)
1/8"10.30.4051.70.0686.80.26955.88102.40.0955.50.21584.81230——
1/4"13.70.5402.20.0889.20.36453.878030.1197.70.30277.91130——
3/8"17.10.6752.30.09112.50.49342.76203.20.12610.70.42363.4920——
1/2"21.30.8402.80.10915.80.62241.46003.70.14713.90.54658.6850——
3/4"26.71.0502.90.11320.90.82433.14803.90.15418.80.74247.6690——
1"33.41.3153.40.13326.61.04931.04504.50.17924.30.95743.4630——
1-1/4"42.21.6603.60.14035.11.38025.53704.90.19132.51.27835.9520——
1-1/2"48.31.9003.70.14540.91.61022.83305.10.20038.11.50032.4470——
2"60.32.3753.90.15452.52.06719.32805.50.21849.31.93927.6400——
2-1/2"732.8755.20.20362.72.46920.730070.276592.32329.0420——
3"88.93.5005.50.21677.93.06817.92607.60.30073.72.90025.5370——
4"114.34.50060.237102.34.02615.22208.60.33797.23.82622.1320——
5"141.35.5636.60.258128.25.04713.11909.50.375122.34.81320.0290——
6"168.36.6257.10.280154.16.06512.4180110.432146.35.76119.3280——
8"219.18.6258.20.322202.77.98111.016012.70.500193.77.62517.2250——
10"273.110.7509.30.365254.510.0209.714015.10.593242.99.56415.9230——
12"323.912.75010.30.406303.211.9389.013017.50.68728911.37615.9230——
Metric PVC-U: EN ISO 1452 outside diameters
16 mm160.630————————
20 mm200.787————————
25 mm250.984———————1.50.059
32 mm321.260——————1.50.0591.90.075
40 mm401.575——————1.60.0632.40.094
50 mm501.969——————20.07930.118
63 mm632.480——————2.50.0983.80.150
75 mm752.953——————2.90.1144.50.177
90 mm903.543——————3.50.1385.40.213
110 mm1104.331——————4.20.1656.60.260
125 mm1254.921——————4.80.1897.40.291
140 mm1405.512——————5.40.2138.30.327
160 mm1606.299——————6.20.2449.50.374
200 mm2007.874——————7.70.30311.90.469
225 mm2258.858——————8.60.33913.40.528
250 mm2509.843——————9.60.37814.80.583
315 mm31512.402——————12.10.47618.70.736
400 mm40015.748——————15.30.60223.70.933

Nominal size, schedule and OD

US PVC uses nominal pipe sizes (NPS) shared with steel pipe. The OD is fixed for each size; the schedule sets the wall. Sch 40 and Sch 80 fit the same fittings' sockets, but Sch 80 has a smaller bore.

To identify a pipe, measure the OD: 0.84 in = 1/2 in, 1.05 = 3/4, 1.315 = 1, 1.66 = 1-1/4, 1.90 = 1-1/2, 2.375 = 2, 3.5 = 3, 4.5 = 4 in. The ID in the chart is computed at the minimum wall; real pipe is slightly smaller inside.

Pressure ratings are for water at 73 °F and fall with temperature: roughly half at 110 °F, and PVC should not carry pressure above 140 °F. Threaded Sch 80 is rated at half its plain rating; do not thread Sch 40 for pressure. Fittings (ASTM D2466/D2467) carry their own, lower ratings, and the system is only as strong as its weakest part.

Metric PVC-U is named by OD in mm (110 mm = 110 mm outside). The wall follows the SDR (OD ÷ wall): SDR 26 is PN 10 and SDR 17 is PN 16 for larger pipe designed with a coefficient of 2.0; small sizes use different SDRs for the same PN, so read the pipe marking.

About PVC Pipe Sizes

DWV (drain, waste, vent) pipe to ASTM D2665 has the Sch 40 dimensions and is marked DWV; cellular-core pipe (ASTM F891) has the same OD with a foam core and is for non-pressure use only.

PVC is not interchangeable with CPVC tubing (CTS sizes) or with furniture-grade pipe of unknown rating. PVC pressure pipe also comes in SDR series (ASTM D2241, e.g. SDR 21 = 200 psi, SDR 26 = 160 psi) with the same OD as Sch 40.

Solvent-weld with primer and cement suited to the size and schedule; large diameters and Sch 80 need heavier-bodied cement and longer cure before pressure testing.

UK and European drainage uses 110 mm (4 in nominal) soil pipe, 32/40/50 mm waste pipe and 68 mm downpipes; these follow EN 1329/EN 1401 and differ from US DWV sizes, so adapters are needed between systems.

Questions

What is the OD of 1/2 inch PVC pipe?

0.840 in (21.3 mm) for Schedule 40 and 80. 3/4 in is 1.050 in, 1 in is 1.315 in.

What is the difference between Schedule 40 and 80 PVC?

Same OD, thicker wall in Sch 80 (e.g. 2 in: 0.154 vs 0.218 in), so a smaller ID and higher pressure rating (280 vs 400 psi at 73 °F).

What pressure can Schedule 40 PVC handle?

At 73 °F from 600 psi (1/2 in) down to 130 psi (12 in). Ratings drop with temperature: about half at 110 °F.

What is the inside diameter of 2 inch PVC?

About 2.067 in (52.5 mm) for Sch 40 at minimum wall and 1.939 in for Sch 80.

Is 110 mm PVC the same as 4 inch?

No. US 4-in PVC is 4.5 in (114.3 mm) OD; metric 110 mm pipe is 4.33 in OD. They need an adapter coupling.

Sources

  1. ASTM D1785: Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80, and 120
  2. Westlake Pipe & Fittings: Sch 40 / Sch 80 pressure pipe data (ASTM D1785 / D2665)
  3. Wavin: PVC Schedule 40 sell sheet (pressure 160–600 psi, temperature factors)
  4. ASTM D2665: PVC Plastic Drain, Waste, and Vent Pipe and Fittings
  5. EN ISO 1452-2: Plastics piping systems for water supply: PVC-U, Part 2 Pipes; ISO 4065 universal wall thickness table

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.