A three-digit capacitor code is in picofarads: two significant digits and a power of ten. 104 = 10 × 10⁴ pF = 100,000 pF = 100 nF = 0.1 µF. A letter after the code is the tolerance (J ±5 %, K ±10 %, M ±20 %); a digit-letter pair in front, such as 2A, is the rated voltage (100 V).
Capacitor codesTap a code for its value and decoding
| Code | Capacitance in pFpF | Capacitance in nFnF | Capacitance in µFµF |
|---|---|---|---|
| Below 1 nF | |||
| 1R0 | 1 | 0.001 | 0.000001 |
| 4R7 | 4.7 | 0.0047 | 0.0000047 |
| 100 | 10 | 0.01 | 0.00001 |
| 220 | 22 | 0.022 | 0.000022 |
| 330 | 33 | 0.033 | 0.000033 |
| 470 | 47 | 0.047 | 0.000047 |
| 101 | 100 | 0.1 | 0.0001 |
| 151 | 150 | 0.15 | 0.00015 |
| 221 | 220 | 0.22 | 0.00022 |
| 331 | 330 | 0.33 | 0.00033 |
| 471 | 470 | 0.47 | 0.00047 |
| 681 | 680 | 0.68 | 0.00068 |
| 1 nF to <1 µF | |||
| 102 | 1,000 | 1 | 0.001 |
| 152 | 1,500 | 1.5 | 0.0015 |
| 222 | 2,200 | 2.2 | 0.0022 |
| 332 | 3,300 | 3.3 | 0.0033 |
| 472 | 4,700 | 4.7 | 0.0047 |
| 682 | 6,800 | 6.8 | 0.0068 |
| 103 | 10,000 | 10 | 0.01 |
| 153 | 15,000 | 15 | 0.015 |
| 223 | 22,000 | 22 | 0.022 |
| 333 | 33,000 | 33 | 0.033 |
| 473 | 47,000 | 47 | 0.047 |
| 683 | 68,000 | 68 | 0.068 |
| 104 | 100,000 | 100 | 0.1 |
| 154 | 150,000 | 150 | 0.15 |
| 224 | 220,000 | 220 | 0.22 |
| 334 | 330,000 | 330 | 0.33 |
| 474 | 470,000 | 470 | 0.47 |
| 684 | 680,000 | 680 | 0.68 |
| 1 µF and up | |||
| 105 | 1,000,000 | 1,000 | 1 |
| 225 | 2,200,000 | 2,200 | 2.2 |
| 475 | 4,700,000 | 4,700 | 4.7 |
| 106 | 10,000,000 | 10,000 | 10 |
| 226 | 22,000,000 | 22,000 | 22 |
| 107 | 100,000,000 | 100,000 | 100 |
No exact match. The nearest sizes:
How to read a capacitor code
Three digits: first two are the value, the third is the number of zeros, in pF. 472 = 47 00 pF = 4.7 nF. 101 = 100 pF; 100 = 10 pF (10 followed by no zeros).
Two digits or a plain number below 100 is the value in pF: 47 = 47 pF. R marks a decimal point: 4R7 = 4.7 pF, 1R0 = 1 pF. Some makers use 8 and 9 as the third digit for ×0.01 and ×0.1 (109 = 1.0 pF).
Tolerance letter after the code: B ±0.1 pF, C ±0.25 pF, D ±0.5 pF, F ±1 %, G ±2 %, J ±5 %, K ±10 %, M ±20 %, Z +80/−20 %. 104K = 100 nF ±10 %.
Voltage code (EIA, two characters) on film and some ceramic capacitors: 0J 6.3 V, 1A 10 V, 1C 16 V, 1E 25 V, 1V 35 V, 1H 50 V, 1J 63 V, 2A 100 V, 2D 200 V, 2E 250 V, 2G 400 V, 2W 450 V, 2J 630 V, 3A 1000 V. 2A104J = 100 V, 100 nF, ±5 %.
Electrolytic capacitors are printed in plain text (470 µF 25 V); the stripe marks the negative lead. SMD ceramic capacitors usually carry no marking at all; measure them or keep them in the reel.
About Capacitor Codes
Small ceramic and film capacitors have no room for "0.1 µF", so IEC 60062 uses the same scheme as resistor SMD codes: significant digits plus a multiplier, always in picofarads. Once you remember that 1 nF = 1000 pF and 1 µF = 1000 nF, the codes read themselves: 102 = 1 nF, 103 = 10 nF, 104 = 100 nF, 105 = 1 µF.
Values follow the E series: E6 (10, 15, 22, 33, 47, 68) for most ceramics and electrolytics, E12 for better parts. A code such as 474 or 225 is therefore far more common than 504 or 255.
Old American schematics and parts use µF for everything and "mmF" or "µµF" for picofarads. 0.001 µF = 1 nF = 102; 0.01 µF = 103; 0.1 µF = 104. "MFD" on old capacitors means µF, not millifarad.
Ceramic capacitors also carry a dielectric code. Class I (C0G/NP0) is stable with temperature and voltage, so use it for filters and timing. Class II (X7R, X5R) packs more capacitance but loses some with temperature and DC bias; Y5V and Z5U lose a great deal and are best avoided for anything that matters.
Codes, pF, nF and µF
| Code | pF | nF | µF |
|---|---|---|---|
| 101 | 100 | 0.1 | 0.0001 |
| 102 | 1,000 | 1 | 0.001 |
| 103 | 10,000 | 10 | 0.01 |
| 104 | 100,000 | 100 | 0.1 |
| 105 | 1,000,000 | 1,000 | 1 |
| 106 | 10,000,000 | 10,000 | 10 |
| 107 | 100,000,000 | 100,000 | 100 |
Tolerance letters
| Letter | Tolerance | Typical on |
|---|---|---|
| B | ±0.1 pF | Small C0G values |
| C | ±0.25 pF | Small C0G values |
| D | ±0.5 pF | Small C0G values |
| F | ±1 % | C0G, film |
| G | ±2 % | C0G, film |
| J | ±5 % | C0G, film |
| K | ±10 % | X7R, X5R, film |
| M | ±20 % | X7R, electrolytic, tantalum |
| Z | +80 / −20 % | Y5V, Z5U |
EIA voltage codes
| Code | Voltage | Code | Voltage |
|---|---|---|---|
| 0G | 4 V | 1K | 80 V |
| 0J | 6.3 V | 2A | 100 V |
| 1A | 10 V | 2D | 200 V |
| 1C | 16 V | 2E | 250 V |
| 1E | 25 V | 2G | 400 V |
| 1V | 35 V | 2W | 450 V |
| 1H | 50 V | 2J | 630 V |
| 1J | 63 V | 3A | 1000 V |
Class II dielectric codes (EIA-198)
Three characters: low temperature, high temperature, capacitance change over that range. X7R = −55 °C to +125 °C, ±15 %. X5R = −55 °C to +85 °C, ±15 %. Y5V = −30 °C to +85 °C, +22/−82 %. Class I C0G (NP0) means 0 ± 30 ppm/K.
| Low temp. | High temp. | Change | |||
|---|---|---|---|---|---|
| X | −55 °C | 5 | +85 °C | F | ±7.5 % |
| Y | −30 °C | 6 | +105 °C | P | ±10 % |
| Z | +10 °C | 7 | +125 °C | R | ±15 % |
| 8 | +150 °C | S | ±22 % | ||
| 9 | +200 °C | T | +22/−33 % | ||
| U | +22/−56 % | ||||
| V | +22/−82 % |
Questions
What is the value of a 104 capacitor?
100,000 pF = 100 nF = 0.1 µF. The code is 10 followed by 4 zeros, in picofarads.
What does 103 mean on a capacitor?
10,000 pF = 10 nF = 0.01 µF.
What does the K in 104K mean?
Tolerance ±10 %. J is ±5 % and M ±20 %.
What does 2A mean on a capacitor?
It is an EIA voltage code: 2A = 100 V. 1H = 50 V, 2E = 250 V, 2J = 630 V.
Is a 100 capacitor 100 pF?
No. 100 is 10 pF (10 × 10⁰). A 100 pF capacitor is marked 101.
How do I convert nF to µF?
Divide by 1000: 100 nF = 0.1 µF, 470 nF = 0.47 µF. From pF to nF divide by 1000 as well: 4700 pF = 4.7 nF.
Sources
- IEC 60062:2016, Marking codes for resistors and capacitors
- EIA-198 / EIA RS-198: Ceramic dielectric capacitors classes I–IV (temperature characteristic codes)
- KEMET: Ceramic capacitor marking and dielectric codes
- Murata: Capacitance, tolerance and rated voltage codes
- Panasonic: Aluminium electrolytic and film capacitor voltage codes
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.