HP14×102 Pile Dimensions & Properties

HP Shapes (Bearing Piles) · HP14

HP14×102 is an AISC HP bearing-pile shape. It is 14 in (355.6 mm) deep and 14.8 in (375.9 mm) wide, with a 0.705 in (17.9 mm) web and 0.705 in (17.9 mm) flanges, and weighs 102 lb/ft (151.8 kg/m). Area 30.1 in² (19,419 mm²); Ix = 1,050 in⁴ (43,704.3 cm⁴), Iy = 380 in⁴ (15,816.8 cm⁴).

dDepth
355.6 mm14 in14 in355.6 mm
bfFlange width
375.9 mm14.8 in14.8 in375.9 mm
twWeb thickness
17.9 mm0.705 in0.705 in17.9 mm
tfFlange thickness
17.9 mm0.705 in0.705 in17.9 mm

Drawing

375.9 mm14.8 in355.6 mm14 intf 17.9 mmtf 0.705 intw 17.9 mmtw 0.705 ink 35.1 mmk 1.38 in
Drawn to scale · Dimensions in mmDimensions in inches

HP14×102 specifications

dDepth14 in355.6 mm
bfFlange width14.8 in375.9 mm
twWeb thickness0.705 in17.9 mm
tfFlange thickness0.705 in17.9 mm
kDesign value1.38 in35.1 mm
kDetailing value1 15/16 in49.2 mm
k1Detailing value1 9/16 in39.7 mm
WWeight102 lb/ft151.8 kg/m
AArea30.1 in²19,419 mm²
IxMoment of inertia, strong axis1,050 in⁴43,704.3 cm⁴
ZxPlastic modulus, strong axis169 in³2769.4 cm³
SxSection modulus, strong axis150 in³2458.1 cm³
rxRadius of gyration, strong axis5.92 in150.4 mm
IyMoment of inertia, weak axis380 in⁴15,816.8 cm⁴
ZyPlastic modulus, weak axis78.8 in³1291.3 cm³
SySection modulus, weak axis51.4 in³842.3 cm³
ryRadius of gyration, weak axis3.56 in90.4 mm
JTorsional constant5.39 in⁴224.35 cm⁴
bf/2tfFlange slenderness10.5
h/twWeb slenderness16.2
Metric designationHP360×152

Also known as

HP360×152

HP shapes of about the same weight in other sizes

All HP Shapes (Bearing Piles) sizes

Compare all 22 shapes in the HP Shapes (Bearing Piles) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
  2. ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.