HP16×121 Pile Dimensions & Properties

HP Shapes (Bearing Piles) · HP16

HP16×121 is an AISC HP bearing-pile shape. It is 15.8 in (401.3 mm) deep and 15.9 in (403.9 mm) wide, with a 0.75 in (19.0 mm) web and 0.75 in (19.0 mm) flanges, and weighs 121 lb/ft (180.1 kg/m). Area 35.8 in² (23,097 mm²); Ix = 1,590 in⁴ (66,180.8 cm⁴), Iy = 504 in⁴ (20,978.1 cm⁴).

dDepth
401.3 mm15.8 in15.8 in401.3 mm
bfFlange width
403.9 mm15.9 in15.9 in403.9 mm
twWeb thickness
19.0 mm0.75 in0.75 in19.0 mm
tfFlange thickness
19.0 mm0.75 in0.75 in19.0 mm

Drawing

403.9 mm15.9 in401.3 mm15.8 intf 19.0 mmtf 0.75 intw 19.0 mmtw 0.75 ink 49.0 mmk 1.93 in
Drawn to scale · Dimensions in mmDimensions in inches

HP16×121 specifications

dDepth15.8 in401.3 mm
bfFlange width15.9 in403.9 mm
twWeb thickness0.75 in19.0 mm
tfFlange thickness0.75 in19.0 mm
kDesign value1.93 in49.0 mm
kDetailing value1 15/16 in49.2 mm
k1Detailing value1 9/16 in39.7 mm
WWeight121 lb/ft180.1 kg/m
AArea35.8 in²23,097 mm²
IxMoment of inertia, strong axis1,590 in⁴66,180.8 cm⁴
ZxPlastic modulus, strong axis226 in³3703.5 cm³
SxSection modulus, strong axis201 in³3293.8 cm³
rxRadius of gyration, strong axis6.66 in169.2 mm
IyMoment of inertia, weak axis504 in⁴20,978.1 cm⁴
ZyPlastic modulus, weak axis97.6 in³1599.4 cm³
SySection modulus, weak axis63.4 in³1038.9 cm³
ryRadius of gyration, weak axis3.75 in95.3 mm
JTorsional constant8.35 in⁴347.55 cm⁴
bf/2tfFlange slenderness10.6
h/twWeb slenderness15.9
Metric designationHP410×181

Also known as

HP410×181

HP shapes of about the same weight in other sizes

All HP Shapes (Bearing Piles) sizes

Compare all 22 shapes in the HP Shapes (Bearing Piles) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
  2. ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.