404T Motor Frame Dimensions
Motor Frame Sizes · NEMA MG 1 (inch)
The 404T frame (NEMA MG 1, inch) has a shaft height of 10 in (254 mm) and a 2 7/8 in (73 mm) shaft 7 1/4 in (184.2 mm) long. Foot holes: 16 in (406.4 mm) across × 12 1/4 in (311.2 mm) along, the first one 6 5/8 in (168.3 mm) from the shaft shoulder; hole diameter 0.813 in (20.6 mm).
- HShaft height (IEC H / NEMA D)
- 254 mm10 in10 in254 mm
- DShaft diameter (IEC D / NEMA U)
- 73 mm2 7/8 in2 7/8 in73 mm
- AFoot holes across (IEC A / NEMA 2E)
- 406.4 mm16 in16 in406.4 mm
- BFoot holes along (IEC B / NEMA 2F)
- 311.2 mm12 1/4 in12 1/4 in311.2 mm
Drawing
404T specifications
| HShaft height (IEC H / NEMA D) | 254 mm10 in |
|---|---|
| AFoot holes across (IEC A / NEMA 2E) | 406.4 mm16 in |
| BFoot holes along (IEC B / NEMA 2F) | 311.2 mm12 1/4 in |
| CShaft shoulder to first hole (IEC C / NEMA BA) | 168.3 mm6 5/8 in |
| KFoot bolt hole (IEC K / NEMA H) | 20.6 mm0.813 in |
| DShaft diameter (IEC D / NEMA U) | 73 mm2 7/8 in |
| EShaft extension (IEC E / NEMA N-W) | 184.2 mm7 1/4 in |
Same shaft height, other foot length
Similar shaft height in the other system
All motor frames
Sources
- IEC 60072-1:2022, Dimensions and output series for rotating electrical machines, Part 1: Frame numbers 56 to 400
- NEMA MG 1: Motors and Generators, Part 4 (dimensions, frame designations)
- Regal Rexnord: Quick reference motor dimensions (NEMA frame chart)
- Motion Industries: NEMA quick reference chart
- Electric Motor Warehouse / Drive Centre: IEC quick reference dimensional charts
- ABB / WEG / Brook Crompton low-voltage motor catalogues: IEC dimension tables
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.