404T Motor Frame Dimensions

Motor Frame Sizes · NEMA MG 1 (inch)

The 404T frame (NEMA MG 1, inch) has a shaft height of 10 in (254 mm) and a 2 7/8 in (73 mm) shaft 7 1/4 in (184.2 mm) long. Foot holes: 16 in (406.4 mm) across × 12 1/4 in (311.2 mm) along, the first one 6 5/8 in (168.3 mm) from the shaft shoulder; hole diameter 0.813 in (20.6 mm).

HShaft height (IEC H / NEMA D)
254 mm10 in10 in254 mm
DShaft diameter (IEC D / NEMA U)
73 mm2 7/8 in2 7/8 in73 mm
AFoot holes across (IEC A / NEMA 2E)
406.4 mm16 in16 in406.4 mm
BFoot holes along (IEC B / NEMA 2F)
311.2 mm12 1/4 in12 1/4 in311.2 mm

Drawing

Drive-end view2E = 406.4 mm2E = 16 inD = 254 mmD = 10 in
Side view2F = 311.2 mm2F = 12 1/4 inBA = 168.3 mmBA = 6 5/8 inN-W = 184.2 mmN-W = 7 1/4 inU = 73 mmU = 2 7/8 in
Mounting dimensions to scale for this frame; body, fan cowl and terminal box are schematic.Drawn to scale · Dimensions in mmDimensions in inches

404T specifications

HShaft height (IEC H / NEMA D)254 mm10 in
AFoot holes across (IEC A / NEMA 2E)406.4 mm16 in
BFoot holes along (IEC B / NEMA 2F)311.2 mm12 1/4 in
CShaft shoulder to first hole (IEC C / NEMA BA)168.3 mm6 5/8 in
KFoot bolt hole (IEC K / NEMA H)20.6 mm0.813 in
DShaft diameter (IEC D / NEMA U)73 mm2 7/8 in
EShaft extension (IEC E / NEMA N-W)184.2 mm7 1/4 in

Same shaft height, other foot length

Similar shaft height in the other system

All motor frames

All 48 motor frames →

Sources

  1. IEC 60072-1:2022, Dimensions and output series for rotating electrical machines, Part 1: Frame numbers 56 to 400
  2. NEMA MG 1: Motors and Generators, Part 4 (dimensions, frame designations)
  3. Regal Rexnord: Quick reference motor dimensions (NEMA frame chart)
  4. Motion Industries: NEMA quick reference chart
  5. Electric Motor Warehouse / Drive Centre: IEC quick reference dimensional charts
  6. ABB / WEG / Brook Crompton low-voltage motor catalogues: IEC dimension tables

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.