230×75×26 PFC Channel Dimensions & Properties
Channels (UPN, UPE, PFC, JIS) · PFC: British parallel flange channels (BS 4-1)
230×75×26 PFC (PFC: British parallel flange channels, BS 4-1) is 230 mm (9.055 in) deep with a 75 mm (2.953 in) flange, a 6.5 mm (0.256 in) web and a 12.5 mm (0.492 in) flange. Mass 25.7 kg/m (17.270 lb/ft), area 32.7 cm² (5.069 in²); strong-axis I = 2,750 cm⁴ (66.07 in⁴), Wel = 239 cm³ (14.58 in³).
- hDepth
- 230 mm9.055 in9.055 in230 mm
- bFlange width
- 75 mm2.953 in2.953 in75 mm
- twWeb thickness
- 6.5 mm0.256 in0.256 in6.5 mm
- tfFlange thickness
- 12.5 mm0.492 in0.492 in12.5 mm
Drawing
230×75×26 PFC specifications
| hDepth | 230 mm9.055 in |
|---|---|
| bFlange width | 75 mm2.953 in |
| twWeb thickness | 6.5 mm0.256 in |
| tfFlange thickness | 12.5 mm0.492 in |
| r1Root radius | 12 mm0.472 in |
| GMass | 25.7 kg/m17.270 lb/ft |
| AArea | 32.7 cm²5.069 in² |
| eCentroid from back of web | 2.3 cm0.906 in |
| IyMoment of inertia, strong axis | 2,750 cm⁴66.07 in⁴ |
| Wel,yElastic modulus, strong axis | 239 cm³14.58 in³ |
| Wpl,yPlastic modulus, strong axis | 278 cm³16.96 in³ |
| iyRadius of gyration, strong axis | 9.17 cm3.610 in |
| IzMoment of inertia, weak axis | 181 cm⁴4.35 in⁴ |
| Wel,zElastic modulus, weak axis | 34.8 cm³2.12 in³ |
| izRadius of gyration, weak axis | 2.35 cm0.925 in |
Also known as
PFC230x75x26
Channels of about the same depth in other series
All Channels (UPN, UPE, PFC, JIS) sizes
Compare all 58 sections in the Channels (UPN, UPE, PFC, JIS) chart →
Sources
- EN 10279:2000, Hot rolled steel channels. Tolerances on shape, dimension and mass
- EN 10365:2017, Hot rolled steel channels, I and H sections. Dimensions and masses
- ArcelorMittal: Sections and Merchant Bars sales programme, UPN and UPE tables
- SCI / BCSA: Steel Building Design: Design Data (Blue Book), parallel flange channels
- JIS G 3192:2024 and JFE Steel building steel handbook, channel section table
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.