230×90×32 PFC Channel Dimensions & Properties

Channels (UPN, UPE, PFC, JIS) · PFC: British parallel flange channels (BS 4-1)

230×90×32 PFC (PFC: British parallel flange channels, BS 4-1) is 230 mm (9.055 in) deep with a 90 mm (3.543 in) flange, a 7.5 mm (0.295 in) web and a 14 mm (0.551 in) flange. Mass 32.2 kg/m (21.637 lb/ft), area 41 cm² (6.355 in²); strong-axis I = 3,520 cm⁴ (84.57 in⁴), Wel = 306 cm³ (18.67 in³).

hDepth
230 mm9.055 in9.055 in230 mm
bFlange width
90 mm3.543 in3.543 in90 mm
twWeb thickness
7.5 mm0.295 in0.295 in7.5 mm
tfFlange thickness
14 mm0.551 in0.551 in14 mm

Drawing

90 mm3.543 in230 mm9.055 intf 14 mmtf 0.551 intw 7.5 mmtw 0.295 ine 2.92 cme 1.150 in
Drawn to scale · Dimensions in mmDimensions in inches

230×90×32 PFC specifications

hDepth230 mm9.055 in
bFlange width90 mm3.543 in
twWeb thickness7.5 mm0.295 in
tfFlange thickness14 mm0.551 in
r1Root radius12 mm0.472 in
GMass32.2 kg/m21.637 lb/ft
AArea41 cm²6.355 in²
eCentroid from back of web2.92 cm1.150 in
IyMoment of inertia, strong axis3,520 cm⁴84.57 in⁴
Wel,yElastic modulus, strong axis306 cm³18.67 in³
Wpl,yPlastic modulus, strong axis355 cm³21.66 in³
iyRadius of gyration, strong axis9.27 cm3.650 in
IzMoment of inertia, weak axis334 cm⁴8.02 in⁴
Wel,zElastic modulus, weak axis55 cm³3.36 in³
izRadius of gyration, weak axis2.86 cm1.126 in

Also known as

PFC230x90x32

Channels of about the same depth in other series

All Channels (UPN, UPE, PFC, JIS) sizes

Compare all 58 sections in the Channels (UPN, UPE, PFC, JIS) chart →

Sources

  1. EN 10279:2000, Hot rolled steel channels. Tolerances on shape, dimension and mass
  2. EN 10365:2017, Hot rolled steel channels, I and H sections. Dimensions and masses
  3. ArcelorMittal: Sections and Merchant Bars sales programme, UPN and UPE tables
  4. SCI / BCSA: Steel Building Design: Design Data (Blue Book), parallel flange channels
  5. JIS G 3192:2024 and JFE Steel building steel handbook, channel section table

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.