UPN 220 Channel Dimensions & Properties

Channels (UPN, UPE, PFC, JIS) · UPN: European standard channels, tapered flanges (EN 10279, DIN 1026-1)

UPN 220 (UPN: European standard channels, tapered flanges, EN 10279, DIN 1026-1) is 220 mm (8.661 in) deep with a 80 mm (3.150 in) flange, a 9 mm (0.354 in) web and a 12.5 mm (0.492 in) flange. Mass 29.4 kg/m (19.756 lb/ft), area 37.4 cm² (5.797 in²); strong-axis I = 2,690 cm⁴ (64.63 in⁴), Wel = 245 cm³ (14.95 in³).

hDepth
220 mm8.661 in8.661 in220 mm
bFlange width
80 mm3.150 in3.150 in80 mm
twWeb thickness
9 mm0.354 in0.354 in9 mm
tfFlange thickness
12.5 mm0.492 in0.492 in12.5 mm

Drawing

80 mm3.150 in220 mm8.661 intf 12.5 mmtf 0.492 intw 9 mmtw 0.354 inr1 12.5 mmr1 0.492 in
Drawn to scale · Dimensions in mmDimensions in inches

UPN 220 specifications

hDepth220 mm8.661 in
bFlange width80 mm3.150 in
twWeb thickness9 mm0.354 in
tfFlange thickness12.5 mm0.492 in
r1Root radius12.5 mm0.492 in
r2Toe radius6.5 mm0.256 in
GMass29.4 kg/m19.756 lb/ft
AArea37.4 cm²5.797 in²
IyMoment of inertia, strong axis2,690 cm⁴64.63 in⁴
Wel,yElastic modulus, strong axis245 cm³14.95 in³
Wpl,yPlastic modulus, strong axis292 cm³17.82 in³
iyRadius of gyration, strong axis8.48 cm3.339 in
IzMoment of inertia, weak axis197 cm⁴4.73 in⁴
Wel,zElastic modulus, weak axis34 cm³2.07 in³
izRadius of gyration, weak axis2.3 cm0.906 in

Also known as

U220UNP220

Channels of about the same depth in other series

All Channels (UPN, UPE, PFC, JIS) sizes

Compare all 58 sections in the Channels (UPN, UPE, PFC, JIS) chart →

Sources

  1. EN 10279:2000, Hot rolled steel channels. Tolerances on shape, dimension and mass
  2. EN 10365:2017, Hot rolled steel channels, I and H sections. Dimensions and masses
  3. ArcelorMittal: Sections and Merchant Bars sales programme, UPN and UPE tables
  4. SCI / BCSA: Steel Building Design: Design Data (Blue Book), parallel flange channels
  5. JIS G 3192:2024 and JFE Steel building steel handbook, channel section table

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.