Channels (UPN, UPE, PFC, JIS) · UPN: European standard channels, tapered flanges (EN 10279, DIN 1026-1)
UPN 220 (UPN: European standard channels, tapered flanges, EN 10279, DIN 1026-1) is 220 mm (8.661 in) deep with a 80 mm (3.150 in) flange, a 9 mm (0.354 in) web and a 12.5 mm (0.492 in) flange. Mass 29.4 kg/m (19.756 lb/ft), area 37.4 cm² (5.797 in²); strong-axis I = 2,690 cm⁴ (64.63 in⁴), Wel = 245 cm³ (14.95 in³).
- hDepth
- 220 mm8.661 in8.661 in220 mm
- bFlange width
- 80 mm3.150 in3.150 in80 mm
- twWeb thickness
- 9 mm0.354 in0.354 in9 mm
- tfFlange thickness
- 12.5 mm0.492 in0.492 in12.5 mm
Drawing
UPN 220 specifications
| hDepth | 220 mm8.661 in |
|---|---|
| bFlange width | 80 mm3.150 in |
| twWeb thickness | 9 mm0.354 in |
| tfFlange thickness | 12.5 mm0.492 in |
| r1Root radius | 12.5 mm0.492 in |
| r2Toe radius | 6.5 mm0.256 in |
| GMass | 29.4 kg/m19.756 lb/ft |
| AArea | 37.4 cm²5.797 in² |
| IyMoment of inertia, strong axis | 2,690 cm⁴64.63 in⁴ |
| Wel,yElastic modulus, strong axis | 245 cm³14.95 in³ |
| Wpl,yPlastic modulus, strong axis | 292 cm³17.82 in³ |
| iyRadius of gyration, strong axis | 8.48 cm3.339 in |
| IzMoment of inertia, weak axis | 197 cm⁴4.73 in⁴ |
| Wel,zElastic modulus, weak axis | 34 cm³2.07 in³ |
| izRadius of gyration, weak axis | 2.3 cm0.906 in |
Also known as
U220UNP220
Channels of about the same depth in other series
All Channels (UPN, UPE, PFC, JIS) sizes
Compare all 58 sections in the Channels (UPN, UPE, PFC, JIS) chart →
Sources
- EN 10279:2000, Hot rolled steel channels. Tolerances on shape, dimension and mass
- EN 10365:2017, Hot rolled steel channels, I and H sections. Dimensions and masses
- ArcelorMittal: Sections and Merchant Bars sales programme, UPN and UPE tables
- SCI / BCSA: Steel Building Design: Design Data (Blue Book), parallel flange channels
- JIS G 3192:2024 and JFE Steel building steel handbook, channel section table
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.