Drywall (Gypsum Board) Thickness, Types and Sheet Sizes
Thicknesses, core types and sheet sizes of gypsum board. The key fact: 1/2 in (12.7 mm) is the standard wall board in the US and 12.5 mm in Europe; fire-rated walls use 5/8-in Type X (15 mm type F in Europe).
Size chartSort by any column, or filter to find a row
| Board | tThicknessmminmm · in | Board type | Fire performance | Common sheet sizes |
|---|---|---|---|---|
| US / Canada (ASTM C1396), 48 in wide | ||||
| 1/4" regular | 6.351/4 | Regular | Not fire-rated | 4×8, 4×10, 4×12 ft |
| 3/8" regular | 9.533/8 | Regular | Not fire-rated | 4×8, 4×10, 4×12 ft |
| 1/2" regular | 12.71/2 | Regular | Not fire-rated | 4×8, 4×10, 4×12 ft |
| 1/2" lightweight | 12.71/2 | Lightweight | Not fire-rated | 4×8, 4×10, 4×12 ft |
| 1/2" ceiling (sag-resistant) | 12.71/2 | Sag-resistant ceiling | Not fire-rated | 4×8, 4×10, 4×12 ft |
| 1/2" moisture/mold-resistant | 12.71/2 | Moisture / mold-resistant | Not fire-rated | 4×8, 4×10, 4×12 ft |
| 1/2" Type C | 12.71/2 | Type C enhanced fire core | Higher ratings in listed assemblies | 4×8, 4×10, 4×12 ft |
| 5/8" regular | 15.885/8 | Regular | Not fire-rated | 4×8, 4×10, 4×12 ft |
| 5/8" Type X | 15.885/8 | Type X fire core | Type X: 1 h in tested assemblies | 4×8, 4×10, 4×12 ft |
| 5/8" Type C | 15.885/8 | Type C enhanced fire core | Higher ratings in listed assemblies | 4×8, 4×10, 4×12 ft |
| 5/8" abuse-resistant | 15.885/8 | Abuse / impact-resistant | Type X: 1 h in tested assemblies | 4×8, 4×10, 4×12 ft |
| Europe (EN 520), 1200 / 1250 mm wide | ||||
| 9.5 mm type A | 9.50.374 | Regular | Not fire-rated | 1200 × 2400–3000 mm |
| 12.5 mm type A | 12.50.492 | Regular | Not fire-rated | 1200 × 2400–3000 mm |
| 12.5 mm type H2 | 12.50.492 | Moisture / mold-resistant | Not fire-rated | 1200 × 2400–3000 mm |
| 12.5 mm type F | 12.50.492 | Type F fire core | Core holds together in fire (EN 520 type F) | 1200 × 2400–3000 mm |
| 12.5 mm type DI | 12.50.492 | Abuse / impact-resistant | Not fire-rated | 1200 × 2400–3000 mm |
| 15 mm type F | 150.591 | Type F fire core | Core holds together in fire (EN 520 type F) | 1200 × 2400–3000 mm |
| 15 mm type A | 150.591 | Regular | Not fire-rated | 1200 × 2400–3000 mm |
| 18 mm type F | 180.709 | Type F fire core | Core holds together in fire (EN 520 type F) | 1200 × 2400–3000 mm |
| 25 mm type F | 250.984 | Type F fire core | Core holds together in fire (EN 520 type F) | 1200 × 2400–3000 mm |
| Japan (JIS A 6901) and Korea (KS F 3504) | ||||
| 9.5 mm (JIS / KS) | 9.50.374 | Regular | Not fire-rated | 910 × 1820 · 900 × 1800 mm |
| 12.5 mm (JIS / KS) | 12.50.492 | Regular | Not fire-rated | 910 × 1820 / 2420 · 900 × 2400 mm |
| 15 mm (JIS / KS) | 150.591 | Regular | Not fire-rated | 910 × 1820 / 2420 mm |
No exact match. The nearest sizes:
How to choose the thickness
1/2 in is the default for walls and for ceilings at 16 in o.c. For ceilings at 24 in o.c. use 5/8 in or 1/2-in sag-resistant ceiling board, especially under insulation or textured finishes. 3/8 in is for overlays and repairs; 1/4 in bends around curves and covers old plaster.
Type X has glass fibres in the core and is 5/8 in thick: it is what garage–house separation walls, furnace rooms and most 1-hour fire-rated walls call for. The rating belongs to the tested assembly (studs, screws, spacing), not to the board alone. Type C adds vermiculite for 2- and 3-hour designs.
European boards carry letter codes from EN 520: A standard, H2 reduced water absorption, F fire (core cohesion at high temperature), D density, I surface hardness, R strength. A board can carry several letters, e.g. DFH2IR.
About Drywall Thickness
US sheets are 48 in wide so the edges land on studs at 16 or 24 in o.c.; 54-in board suits 9-ft walls hung horizontally. Lengths run 8, 9, 10, 12, 14 and 16 ft; longer sheets mean fewer butt joints.
Tapered long edges let joint tape and compound sit flush. Hang the long edge perpendicular to framing on ceilings and walls where possible; butt (short) ends should fall on framing and be staggered.
Moisture-resistant ("green" or "purple") board is fine for bathroom walls outside the wet zone, but behind tile in showers use cement board or a gypsum product rated for wet areas with a waterproofing membrane.
In Japan the standard sheet is 910 × 1820 mm (3 × 6 shaku), matching 455-mm stud spacing; in Korea 900 × 1800 mm sheets dominate. Both use 9.5 mm for ceilings and 12.5 mm for walls as the usual pairing.
Sheet sizes
| Market | Width | Lengths | Thicknesses |
|---|---|---|---|
| US / Canada | 48 in (54 in) | 8, 9, 10, 12, 14, 16 ft | 1/4, 3/8, 1/2, 5/8 in |
| Europe | 1200 or 1250 mm (600/625/900 narrow) | 2000–3000 mm | 9.5, 12.5, 15, 18, 25 mm |
| UK | 1200 mm | 1800, 2400, 2700, 3000 mm | 9.5, 12.5, 15 mm |
| Japan | 910 mm | 1820, 2420 mm | 9.5, 12.5, 15 mm |
| Korea | 900 mm | 1800, 2400 mm | 9.5, 12.5 mm |
Questions
What is the standard drywall thickness?
1/2 in (12.7 mm) for walls in the US; 12.5 mm in Europe. Ceilings at 24 in o.c. call for 5/8 in or 1/2-in sag-resistant board.
What thickness is Type X drywall?
5/8 in (15.9 mm). One layer each side of 2×4 studs at 16 in o.c. makes a 1-hour wall in common tested designs.
What size do drywall sheets come in?
48 in wide by 8, 9, 10, 12, 14 or 16 ft long in the US (54-in widths exist). Europe: 1200 or 1250 mm wide, 2000–3000 mm long. Japan: 910 × 1820 mm.
Is 3/8 drywall OK for walls?
Only over framing at 16 in o.c. or as an overlay; it sags and dents easily. Use 1/2 in for new walls.
What is 1/4 inch drywall used for?
Curved walls (bent dry or damp), and laminating over old plaster or paneling. It is not meant to span studs alone.
Sources
- ASTM C1396/C1396M: Standard Specification for Gypsum Board
- Gypsum Association GA-216: Application and Finishing of Gypsum Panel Products (framing spacing)
- ASTM C840: Application and Finishing of Gypsum Board; IRC R702.3 Gypsum board and gypsum panel products
- EN 520: Gypsum plasterboards, definitions, requirements and test methods (types A, D, E, F, H, I, P, R)
- JIS A 6901: Gypsum board products (Japan); KS F 3504: Gypsum boards (Korea)
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.