SWG Wire Gauge Chart (British Standard Wire Gauge)

The Imperial Standard Wire Gauge, from 7/0 (0.500 in) down to 50 SWG (0.001 in). SWG numbers are not AWG numbers: 14 SWG is 2.03 mm, while 14 AWG is 1.63 mm. The same number is roughly two AWG sizes thicker in SWG.

57 gaugesChecked 2026-11-154 sources
0.10.20.5125107/04/002468101214161820222426283032343638404/02/01/02468101214161820222426283032343638SWGmmAWG
Logarithmic diameter scale in mm. Left: SWG, right: AWG. At the same number the SWG wire is thicker.

Size chartDiameters as defined by BS 3737; mm converted exactly

57 of 57
GaugedDiametermminACross-sectionmm²Nearest AWG (diameter)
7/0 SWG12.7000.50001274/0 AWG (11.68 mm)
6/0 SWG11.7860.46401094/0 AWG (11.68 mm)
5/0 SWG10.9730.432094.63/0 AWG (10.40 mm)
4/0 SWG10.1600.400081.13/0 AWG (10.40 mm)
3/0 SWG9.4490.372070.12/0 AWG (9.27 mm)
2/0 SWG8.8390.348061.42/0 AWG (9.27 mm)
0 SWG8.2300.324053.21/0 AWG (8.25 mm)
1 SWG7.6200.300045.61 AWG (7.35 mm)
2 SWG7.0100.276038.61 AWG (7.35 mm)
3 SWG6.4010.252032.22 AWG (6.54 mm)
4 SWG5.8930.232027.33 AWG (5.83 mm)
5 SWG5.3850.212022.84 AWG (5.19 mm)
6 SWG4.8770.192018.75 AWG (4.62 mm)
7 SWG4.4700.176015.75 AWG (4.62 mm)
8 SWG4.0640.1600136 AWG (4.12 mm)
9 SWG3.6580.144010.57 AWG (3.66 mm)
10 SWG3.2510.12808.38 AWG (3.26 mm)
11 SWG2.9460.11606.829 AWG (2.91 mm)
12 SWG2.6420.10405.4810 AWG (2.59 mm)
13 SWG2.3370.09204.2911 AWG (2.30 mm)
14 SWG2.0320.08003.2412 AWG (2.05 mm)
15 SWG1.8290.07202.6313 AWG (1.83 mm)
16 SWG1.6260.06402.0814 AWG (1.63 mm)
17 SWG1.4220.05601.5915 AWG (1.45 mm)
18 SWG1.2190.04801.1716 AWG (1.29 mm)
19 SWG1.0160.04000.81118 AWG (1.02 mm)
20 SWG0.9140.03600.65719 AWG (0.912 mm)
21 SWG0.8130.03200.51920 AWG (0.812 mm)
22 SWG0.7110.02800.39721 AWG (0.723 mm)
23 SWG0.6100.02400.29222 AWG (0.644 mm)
24 SWG0.5590.02200.24523 AWG (0.573 mm)
25 SWG0.5080.02000.20324 AWG (0.511 mm)
26 SWG0.4570.01800.16425 AWG (0.455 mm)
27 SWG0.4170.01640.13626 AWG (0.405 mm)
28 SWG0.3760.01480.11127 AWG (0.361 mm)
29 SWG0.3450.01360.093727 AWG (0.361 mm)
30 SWG0.3150.01240.077928 AWG (0.321 mm)
31 SWG0.2950.01160.068229 AWG (0.286 mm)
32 SWG0.2740.01080.059129 AWG (0.286 mm)
33 SWG0.2540.01000.050730 AWG (0.255 mm)
34 SWG0.2340.00920.042931 AWG (0.227 mm)
35 SWG0.2130.00840.035832 AWG (0.202 mm)
36 SWG0.1930.00760.029332 AWG (0.202 mm)
37 SWG0.1730.00680.023433 AWG (0.180 mm)
38 SWG0.1520.00600.018234 AWG (0.160 mm)
39 SWG0.1320.00520.013736 AWG (0.127 mm)
40 SWG0.1220.00480.011736 AWG (0.127 mm)
41 SWG0.1120.00440.009837 AWG (0.113 mm)
42 SWG0.1020.00400.008138 AWG (0.101 mm)
43 SWG0.0910.00360.006639 AWG (0.090 mm)
44 SWG0.0810.00320.005240 AWG (0.080 mm)
45 SWG0.0710.00280.00441 AWG (0.071 mm)
46 SWG0.0610.00240.002942 AWG (0.063 mm)
47 SWG0.0510.00200.00244 AWG (0.050 mm)
48 SWG0.0410.00160.001346 AWG (0.040 mm)
49 SWG0.0300.00120.000748 AWG (0.032 mm)
50 SWG0.0250.00100.000550 AWG (0.025 mm)

How the SWG numbers work

SWG was fixed by the British Board of Trade in 1883 and later published as BS 3737. Each gauge number is simply a defined diameter in inches: 7/0 is 0.500 in, 0 is 0.324 in, 10 is 0.128 in, 20 is 0.036 in, 30 is 0.0124 in and 50 is 0.001 in (one thou). Larger numbers are thinner wire; sizes above 0 are written 2/0 … 7/0 (or 00 … 0000000).

Unlike AWG, SWG is not a single geometric series. It runs in constant steps within ranges: 0.012 in per gauge from 10 to 14 SWG, 0.008 in from 14 to 19, 0.004 in from 19 to 23, and only 0.0004 in from 40 to 49. There is no formula, so use the table.

To identify a wire, measure the bare conductor with a micrometer or caliper and find the nearest diameter. A 2.0 mm wire is 14 SWG (2.032 mm); 1.2 mm is 18 SWG (1.219 mm); 0.5 mm is close to 25 SWG (0.508 mm). For stranded wire, measure one strand.

About SWG Wire Gauge

The table lists all 57 SWG sizes with the legal diameter in inches, the exact metric conversion (1 in = 25.4 mm) and the cross-sectional area of a round wire of that diameter. The last column gives the AWG size whose diameter is closest, with its diameter in mm. Use it when a British drawing or an old catalogue calls for SWG and only AWG or metric wire is at hand.

BS 3737 was withdrawn and replaced by metric sizes (BS 6722), so new British cable is specified in mm² and wire in mm. SWG survives in a few places: enamelled copper winding wire, piano and spring wire, fuse wire, jewellery and craft wire, steel tube wall thickness ("16 gauge tube" = 0.064 in = 1.63 mm), guitar and model-engineering suppliers, and older UK and Commonwealth drawings.

Do not mix up SWG with AWG (the North American gauge), the old Birmingham Wire Gauge (BWG, still used for hypodermic needles and some tube) or sheet-metal gauges. They all use numbers from 0 to about 40, and they all differ: for gauge 18, SWG is 1.219 mm, AWG 1.024 mm, BWG 1.245 mm and US Manufacturers' Standard steel sheet 1.214 mm.

Common SWG sizes and what they are used for

Typical uses; the trade still asks for these by gauge number.

SWGDiameterTypical use
103.25 mm (0.128 in)Fencing and tie wire, heavy springs
142.03 mm (0.080 in)Galvanised garden and tie wire, chain-link fence wire
161.63 mm (0.064 in)Steel tube wall ("16 gauge"), bending wire, earthing straps
181.22 mm (0.048 in)Craft and jewellery wire, model engineering, tube walls
200.91 mm (0.036 in)Jewellery wire, binding wire
22–260.71–0.46 mmEnamelled winding wire, tinned copper wire, wire-wrap substitutes
30–400.32–0.12 mmFine winding wire for transformers, relays, pickups

SWG, AWG and mm² side by side

The same gauge number is thicker in SWG than in AWG for most of the range, by about two AWG steps around 10–20 and by four steps near 40 (40 SWG = 0.122 mm ≈ 36 AWG). For copper conductors sold in mm², convert via the area column: 1.5 mm² is between 17 and 18 SWG (1.38 mm diameter), 2.5 mm² is near 16 SWG (1.78 mm). The AWG chart and the metric wire chart give resistance and ampacity.

Questions

What is 14 SWG in mm?

14 SWG is 0.080 in = 2.032 mm in diameter, with a cross-section of 3.24 mm². The nearest AWG is 12 AWG (2.05 mm).

Is SWG the same as AWG?

No. SWG (British Imperial Standard Wire Gauge) and AWG (American Wire Gauge) use different diameters for the same number. 18 SWG is 1.219 mm, 18 AWG is 1.024 mm. The SWG wire is about two AWG sizes thicker (close to 16 AWG, 1.29 mm).

What is 18 SWG in mm and inches?

18 SWG is 0.048 in, or 1.219 mm, with a cross-section of 1.17 mm².

How thick is 16 gauge (SWG) steel tube?

In British tube catalogues "16 gauge" means 16 SWG wall thickness: 0.064 in = 1.626 mm. 18 gauge is 1.219 mm, 14 gauge 2.032 mm and 10 gauge 3.251 mm.

Is there a formula for SWG?

No. SWG diameters were defined as a list in 1883 and run in fixed steps over ranges (for example 0.008 in per gauge from 14 to 19 SWG and 0.004 in from 19 to 23 SWG). AWG, by contrast, follows d = 0.005 in × 92^((36 − n)/39).

Sources

  1. BS 3737:1964, Specification for the Imperial Standard Wire Gauge (withdrawn); diameters as legalised by the Board of Trade, 1883
  2. Engineering ToolBox: SWG, Standard Wire Gauge (inch and mm table)
  3. R. Rowlett, How Many? A Dictionary of Units of Measurement: wire gauges (UNC Chapel Hill)
  4. ASTM B258: AWG nominal diameters (for the nearest-AWG column)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.