[-300×90×9×13 Channel Dimensions & Properties

Channels (UPN, UPE, PFC, JIS) · JIS channels (JIS G 3192)

[-300×90×9×13 (JIS channels, JIS G 3192) is 300 mm (11.811 in) deep with a 90 mm (3.543 in) flange, a 9 mm (0.354 in) web and a 13 mm (0.512 in) flange. Mass 38.1 kg/m (25.602 lb/ft), area 48.57 cm² (7.528 in²); strong-axis I = 6,440 cm⁴ (154.72 in⁴), Wel = 429 cm³ (26.18 in³).

hDepth
300 mm11.811 in11.811 in300 mm
bFlange width
90 mm3.543 in3.543 in90 mm
twWeb thickness
9 mm0.354 in0.354 in9 mm
tfFlange thickness
13 mm0.512 in0.512 in13 mm

Drawing

90 mm3.543 in300 mm11.811 intf 13 mmtf 0.512 intw 9 mmtw 0.354 ine 2.22 cme 0.874 in
Flanges drawn parallel; toe radius not drawn.Drawn to scale · Dimensions in mmDimensions in inches

[-300×90×9×13 specifications

hDepth300 mm11.811 in
bFlange width90 mm3.543 in
twWeb thickness9 mm0.354 in
tfFlange thickness13 mm0.512 in
r1Root radius14 mm0.551 in
r2Toe radius7 mm0.276 in
GMass38.1 kg/m25.602 lb/ft
AArea48.57 cm²7.528 in²
eCentroid from back of web2.22 cm0.874 in
IyMoment of inertia, strong axis6,440 cm⁴154.72 in⁴
Wel,yElastic modulus, strong axis429 cm³26.18 in³
iyRadius of gyration, strong axis11.5 cm4.528 in
IzMoment of inertia, weak axis309 cm⁴7.42 in⁴
Wel,zElastic modulus, weak axis45.7 cm³2.79 in³
izRadius of gyration, weak axis2.52 cm0.992 in

Also known as

C-300x90x9x13C300x90

Channels of about the same depth in other series

All Channels (UPN, UPE, PFC, JIS) sizes

Compare all 58 sections in the Channels (UPN, UPE, PFC, JIS) chart →

Sources

  1. EN 10279:2000, Hot rolled steel channels. Tolerances on shape, dimension and mass
  2. EN 10365:2017, Hot rolled steel channels, I and H sections. Dimensions and masses
  3. ArcelorMittal: Sections and Merchant Bars sales programme, UPN and UPE tables
  4. SCI / BCSA: Steel Building Design: Design Data (Blue Book), parallel flange channels
  5. JIS G 3192:2024 and JFE Steel building steel handbook, channel section table

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.