260×90×35 PFC Channel Dimensions & Properties
Channels (UPN, UPE, PFC, JIS) · PFC: British parallel flange channels (BS 4-1)
260×90×35 PFC (PFC: British parallel flange channels, BS 4-1) is 260 mm (10.236 in) deep with a 90 mm (3.543 in) flange, a 8 mm (0.315 in) web and a 14 mm (0.551 in) flange. Mass 34.8 kg/m (23.385 lb/ft), area 44.4 cm² (6.882 in²); strong-axis I = 4,730 cm⁴ (113.64 in⁴), Wel = 364 cm³ (22.21 in³).
- hDepth
- 260 mm10.236 in10.236 in260 mm
- bFlange width
- 90 mm3.543 in3.543 in90 mm
- twWeb thickness
- 8 mm0.315 in0.315 in8 mm
- tfFlange thickness
- 14 mm0.551 in0.551 in14 mm
Drawing
260×90×35 PFC specifications
| hDepth | 260 mm10.236 in |
|---|---|
| bFlange width | 90 mm3.543 in |
| twWeb thickness | 8 mm0.315 in |
| tfFlange thickness | 14 mm0.551 in |
| r1Root radius | 12 mm0.472 in |
| GMass | 34.8 kg/m23.385 lb/ft |
| AArea | 44.4 cm²6.882 in² |
| eCentroid from back of web | 2.74 cm1.079 in |
| IyMoment of inertia, strong axis | 4,730 cm⁴113.64 in⁴ |
| Wel,yElastic modulus, strong axis | 364 cm³22.21 in³ |
| Wpl,yPlastic modulus, strong axis | 425 cm³25.94 in³ |
| iyRadius of gyration, strong axis | 10.3 cm4.055 in |
| IzMoment of inertia, weak axis | 353 cm⁴8.48 in⁴ |
| Wel,zElastic modulus, weak axis | 56.3 cm³3.44 in³ |
| izRadius of gyration, weak axis | 2.82 cm1.110 in |
Also known as
PFC260x90x35
Channels of about the same depth in other series
All Channels (UPN, UPE, PFC, JIS) sizes
Compare all 58 sections in the Channels (UPN, UPE, PFC, JIS) chart →
Sources
- EN 10279:2000, Hot rolled steel channels. Tolerances on shape, dimension and mass
- EN 10365:2017, Hot rolled steel channels, I and H sections. Dimensions and masses
- ArcelorMittal: Sections and Merchant Bars sales programme, UPN and UPE tables
- SCI / BCSA: Steel Building Design: Design Data (Blue Book), parallel flange channels
- JIS G 3192:2024 and JFE Steel building steel handbook, channel section table
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.