UPE 270 Channel Dimensions & Properties

Channels (UPN, UPE, PFC, JIS) · UPE: European channels, parallel flanges

UPE 270 (UPE: European channels, parallel flanges) is 270 mm (10.630 in) deep with a 95 mm (3.740 in) flange, a 7.5 mm (0.295 in) web and a 13.5 mm (0.531 in) flange. Mass 35.2 kg/m (23.653 lb/ft), area 44.8 cm² (6.944 in²); strong-axis I = 5,250 cm⁴ (126.13 in⁴), Wel = 389 cm³ (23.74 in³).

hDepth
270 mm10.630 in10.630 in270 mm
bFlange width
95 mm3.740 in3.740 in95 mm
twWeb thickness
7.5 mm0.295 in0.295 in7.5 mm
tfFlange thickness
13.5 mm0.531 in0.531 in13.5 mm

Drawing

95 mm3.740 in270 mm10.630 intf 13.5 mmtf 0.531 intw 7.5 mmtw 0.295 ine 2.89 cme 1.138 in
Drawn to scale · Dimensions in mmDimensions in inches

UPE 270 specifications

hDepth270 mm10.630 in
bFlange width95 mm3.740 in
twWeb thickness7.5 mm0.295 in
tfFlange thickness13.5 mm0.531 in
r1Root radius15 mm0.591 in
GMass35.2 kg/m23.653 lb/ft
AArea44.8 cm²6.944 in²
eCentroid from back of web2.89 cm1.138 in
IyMoment of inertia, strong axis5,250 cm⁴126.13 in⁴
Wel,yElastic modulus, strong axis389 cm³23.74 in³
Wpl,yPlastic modulus, strong axis451 cm³27.52 in³
iyRadius of gyration, strong axis10.8 cm4.252 in
IzMoment of inertia, weak axis401 cm⁴9.63 in⁴
Wel,zElastic modulus, weak axis61 cm³3.72 in³
izRadius of gyration, weak axis2.99 cm1.177 in

Channels of about the same depth in other series

All Channels (UPN, UPE, PFC, JIS) sizes

Compare all 58 sections in the Channels (UPN, UPE, PFC, JIS) chart →

Sources

  1. EN 10279:2000, Hot rolled steel channels. Tolerances on shape, dimension and mass
  2. EN 10365:2017, Hot rolled steel channels, I and H sections. Dimensions and masses
  3. ArcelorMittal: Sections and Merchant Bars sales programme, UPN and UPE tables
  4. SCI / BCSA: Steel Building Design: Design Data (Blue Book), parallel flange channels
  5. JIS G 3192:2024 and JFE Steel building steel handbook, channel section table

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.