Ethernet Cable Categories: Cat5e, Cat6, Cat6A, Cat7, Cat8
Twisted-pair cable categories from Cat3 to Cat8.2. The practical summary: Cat5e runs 1 Gbit/s (and 2.5 Gbit/s) over 100 m, Cat6 10 Gbit/s only to about 55 m, Cat6A 10 Gbit/s over the full 100 m, and Cat8 25/40 Gbit/s but only over 30 m channels inside data centres.
Category comparisonTap a category for its specs and cross-section
| Category | BandwidthMHz | Max. speed (full channel) | Channel lengthmft | 10GBASE-T reachmft | ISO/IEC 11801 class | Typical conductor | Typical shielding |
|---|---|---|---|---|---|---|---|
| Cat3 | 16 | 10 Mbit/s | 100328 | — | Class C | 22–24 AWG | U/UTP |
| Cat5 | 100 | 100 Mbit/s | 100328 | — | Class D (1995) | 22–24 AWG | U/UTP |
| Cat5e | 100 | 2.5 Gbit/s | 100328 | — | Class D | 22–24 AWG | U/UTP, F/UTP |
| Cat6 | 250 | 5 Gbit/s | 100328 | 55180 | Class E | 22–24 AWG | U/UTP, F/UTP |
| Cat6A | 500 | 10 Gbit/s | 100328 | 100328 | Class EA | 22–24 AWG | U/UTP, F/UTP, U/FTP, S/FTP |
| Cat7 | 600 | 10 Gbit/s | 100328 | 100328 | Class F | 22–24 AWG | S/FTP |
| Cat7A | 1000 | 10 Gbit/s | 100328 | 100328 | Class FA | 22–24 AWG | S/FTP |
| Cat8 / Cat8.1 | 2000 | 40 Gbit/s | 3098 | — | Class I (Cat 8.1) | 22–24 AWG | U/FTP, F/UTP |
| Cat8.2 | 2000 | 40 Gbit/s | 3098 | — | Class II (Cat 8.2) | 22–24 AWG | F/FTP, S/FTP |
No exact match. The nearest sizes:
Reading category, class and shielding codes
Category (TIA, North America) and class (ISO/IEC 11801, international) describe the same thing for a complete link: Cat5e ≈ Class D, Cat6 ≈ Class E, Cat6A ≈ Class EA, Cat8 ≈ Class I. Cat7 (Class F) and Cat7A (Class FA) exist only in ISO and need special connectors (GG45, TERA, ARJ45) to deliver their rating; with ordinary RJ45 plugs a "Cat7" cable performs as Cat6A.
The bandwidth in MHz is the frequency up to which the cable's loss and crosstalk are specified. It is not the data rate: 1000BASE-T moves 1 Gbit/s inside 100 MHz by using all four pairs in both directions with multi-level coding.
Shielding codes (ISO/IEC 11801 notation) have the form X/YTP: the letters before the slash are the overall screen, the letter before TP is the screen around each pair. U = unshielded, F = foil, S = braid, SF = braid plus foil. So U/UTP has no shield at all, F/UTP an overall foil, U/FTP foil on each pair, S/FTP an overall braid plus foil on each pair. Older names such as "STP" and "FTP" are ambiguous; ask for the code.
Channel length is the total of the 90 m permanent link plus up to 10 m of patch cords (100 m), or for Cat8 a 24 m link plus cords (30 m). Stranded patch cable has more loss than solid cable, so long runs should be solid-core.
About Ethernet Cable Categories
All categories use four twisted pairs and, except Cat7/7A/8.2, the familiar RJ45 (8P8C) connector, and all higher categories are backwards compatible: a Cat6A link carries 100 Mbit/s and 1 Gbit/s equipment without problems. The speed column gives the fastest IEEE 802.3 BASE-T standard the category supports over its full channel length.
For new building wiring the usual choice today is Cat6A: it supports 10GBASE-T to every outlet, handles the heat of 90 W PoE++ (IEEE 802.3bt) bundles better thanks to its larger conductors, and Wi-Fi 6/7 access points already need 2.5 or 5 Gbit/s uplinks. Cat6 is still fine for desks that will stay at 1 Gbit/s, and Cat5e for anything that never needs more than 1–2.5 Gbit/s.
Installation cable uses solid copper conductors of 22 to 24 AWG (ANSI/TIA-568; 26 AWG is allowed for shorter cords). Shielding is a product choice, not set by the category. Shielded cable only works if the shield is bonded through shielded jacks and patch panels to earth; a half-shielded installation can be worse than plain U/UTP.
Beware of copper-clad aluminium (CCA) cable sold as "Cat6": it does not meet the TIA/ISO conductor requirements, has about 60 % higher resistance, heats more with PoE and breaks more easily. Genuine category cable is solid or stranded copper and printed with the category and a listing (e.g. CMR, CMP, or EN 50575 CPR class).
T568A and T568B pin assignments
Both schemes are electrically identical; only pairs 2 (orange) and 3 (green) swap places. Use the same scheme at both ends for a straight-through cable. T568B is most common in commercial cabling in the US, T568A is the TIA preference and required by some government and residential specifications. A cable with A at one end and B at the other is a crossover cable, unnecessary for modern Auto-MDI-X equipment.
| Pin | T568A | T568B | 10/100BASE-T | 1000BASE-T and faster |
|---|---|---|---|---|
| 1 | white/green | white/orange | TX+ | BI_DA+ |
| 2 | green | orange | TX− | BI_DA− |
| 3 | white/orange | white/green | RX+ | BI_DB+ |
| 4 | blue | blue | — | BI_DC+ |
| 5 | white/blue | white/blue | — | BI_DC− |
| 6 | orange | green | RX− | BI_DB− |
| 7 | white/brown | white/brown | — | BI_DD+ |
| 8 | brown | brown | — | BI_DD− |
Shielding codes at a glance
Overall screen / pair screen.
| Code | Overall screen | Pair screen | Old names |
|---|---|---|---|
| U/UTP | none | none | UTP |
| F/UTP | foil | none | FTP, ScTP |
| U/FTP | none | foil | STP (pair-shielded) |
| S/FTP | braid | foil | PiMF, SSTP |
| SF/UTP | braid + foil | none | S-FTP |
Questions
What is the difference between Cat5e, Cat6 and Cat6A?
Bandwidth and reach at 10 Gbit/s. Cat5e: 100 MHz, 1 and 2.5 Gbit/s over 100 m. Cat6: 250 MHz, 1–5 Gbit/s over 100 m, 10 Gbit/s only up to about 55 m. Cat6A: 500 MHz, 10 Gbit/s over the full 100 m.
How long can an Ethernet cable be?
100 m (328 ft) per channel for Cat5e, Cat6 and Cat6A: a 90 m permanent link plus up to 10 m of patch cords. Cat8 channels are limited to 30 m. Beyond that you need a switch, a media converter to fibre, or an extender.
Is Cat7 better than Cat6A?
On paper (600 vs 500 MHz), but in practice no: Cat7 is not a TIA category, needs GG45/TERA connectors to reach its rating, and with RJ45 plugs it is certified as Cat6A. Both carry 10 Gbit/s over 100 m.
Should I use T568A or T568B?
Either, as long as both ends of every cable and the whole installation use the same scheme. They perform identically; T568B is more common in US commercial work, T568A in residential and government specifications.
What does U/FTP or S/FTP mean?
The letters before the slash describe the overall screen, the letters before TP the screen around each pair. U/FTP = no overall screen, foil around each pair; S/FTP = overall braid plus foil around each pair; U/UTP = no shielding at all.
What AWG is Cat6 cable?
ANSI/TIA-568 requires solid installation cable of 22 to 24 AWG and allows 26 AWG for shorter cords; Cat6 products range from 22 to 26 AWG. Thin 26 AWG patch cords are meant for short lengths only.
Sources
- ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components Standard (Categories 3, 5e, 6, 6A, 8)
- ISO/IEC 11801-1:2017, Information technology, generic cabling for customer premises (classes D, E, EA, F, FA, I, II; shield naming Annex)
- IEEE 802.3: 10BASE-T, 100BASE-TX, 1000BASE-T, 2.5G/5GBASE-T (802.3bz), 10GBASE-T (802.3an), 25G/40GBASE-T (802.3bq)
- TIA TSB-155: Guidelines for the assessment of installed Category 6 cabling to support 10GBASE-T (up to 55 m)
- ANSI/TIA-568.0 / 568.1: T568A and T568B pin/pair assignments