Wire Rope Size & Breaking Strength Chart

Minimum breaking force of steel wire rope by diameter, from the US tables (6×19 and 6×36 class, IWRC, EIPS and IPS grade), EN 12385-4 for metric rope and MIL-DTL-83420 for 7×19 aircraft cable. A 1/2 in EIPS IWRC rope breaks at 13.3 tons (26,600 lb); at the 5:1 design factor for slings it is good for 5,320 lb.

42 sizesChecked 2026-11-158 sources
6×19 Seale IWRC6×36 WS IWRC8×19 Seale FC7×19 aircraft cable
Schematic sections. 6×19: fewer, thicker wires, abrasion-resistant. 6×36: more, finer wires, flexible. 8×19: eight strands, often fibre core, for elevators. 7×19: aircraft cable with a strand core.Proportions shown, not to scale

Size chartTap a size for its drawing and full specs

42 of 42
DiameterdRope diametermminmm · inMinimum breaking force (EIPS / 1960 / MIL)kNlbfkN · lbfMin. breaking force, lower grade (IPS / 1770)kNlbfkN · lbfWLL at 5:1 (EIPS / 1960)kNlbfkN · lbfApprox. weight (6×19 IWRC)kg/mlb/ftkg/m · lb/ft
6×19 / 6×36 class IWRC, bright: EIPS (and IPS), ASTM A1023 / RR-W-410
1/4″6.40.25030.26,80026.25,8806.11,3600.170.12
5/16″7.90.31346.910,54040.79,1609.42,1080.270.18
3/8″9.50.37567.215,10058.413,12013.43,0200.390.26
7/16″11.10.43790.720,40079.117,78018.14,0800.520.35
1/2″12.70.500118.326,600102.323,00023.75,3200.690.46
9/16″14.30.563149.533,600—29.96,7200.880.59
5/8″15.90.625183.341,200159.235,80036.78,2401.070.72
3/4″19.10.750261.658,800227.751,20052.311,7601.551.04
7/8″22.20.875354.179,600307.869,20070.815,9202.111.42
1″25.41.000459.9103,400399.589,80092.020,6802.751.85
1-1/8″28.61.125578.3130,000—115.726,0003.482.34
1-1/4″31.81.250710.8159,800—142.231,9604.302.89
1-3/8″34.91.375854.1192,000—170.838,4005.213.50
1-1/2″38.11.5001,014.2228,000—202.845,6006.194.16
1-5/8″41.31.6251,174.3264,000—234.952,8007.264.88
1-3/4″44.51.7501,361.2306,000—272.261,200—
1-7/8″47.61.8751,548.0348,000—309.669,6009.676.50
2″50.82.0001,761.5396,000—352.379,200—
Metric 6×36WS-IWRC (and 6×19 class): EN 12385-4, grade 1960 (and 1770)
6 mm60.23625.15,64322.75,1035.01,124—
8 mm80.31544.710,04940.39,0608.92,001—
10 mm100.39469.815,69263.014,16314.03,147—
12 mm120.472100.522,59390.720,39020.14,519—
14 mm140.551136.830,754123.527,76427.46,160—
16 mm160.630178.640,151161.336,26235.78,026—
18 mm180.709226.150,829204.245,90645.210,161—
20 mm200.787279.162,744252.056,65255.812,544—
22 mm220.866337.775,918305.068,56767.515,175—
24 mm240.945401.990,351362.981,58380.418,075—
26 mm261.024471.7106,042426.095,76994.321,199—
28 mm281.102547.0122,970494.0111,056109.424,594—
32 mm321.260714.5160,626645.2145,047142.932,125—
36 mm361.417904.3203,295816.6183,579180.940,668—
40 mm401.5751,116.4250,9771,008.2226,652223.350,200—
Galvanized aircraft cable 7×19 / 7×7: MIL-DTL-83420
1/16″ 7×71.60.0632.1480———
3/32″ 7×192.40.0944.41,000———
1/8″ 7×193.20.1258.92,000———
5/32″ 7×1940.15612.52,800———
3/16″ 7×194.80.18718.74,200———
7/32″ 7×195.60.21924.95,600———
1/4″ 7×196.40.25031.17,000———
5/16″ 7×197.90.31343.69,800———
3/8″ 7×199.50.37564.114,400———

How to read a wire rope designation

3/4" 6×36 IWRC EIPS RRL reads: 3/4 in diameter, 6 strands of about 36 wires each, independent wire rope core, extra improved plow steel grade, right regular lay. The first number is the strand count, the second the (nominal) wires per strand. "Class" ropes group several real constructions: 6×19 class covers 15–26 wires per strand (6×19 Seale, 6×25 Filler, 6×26 WS), 6×36 class 27–49 wires (6×31, 6×36 WS, 6×41).

Grades: IPS (improved plow steel), EIPS (extra improved, about 15 % stronger), EEIPS (extra extra improved, about 10 % above EIPS). In metric rope the grade is the wire tensile strength in N/mm²: 1770 and 1960 are the common ones; 1960 is roughly equivalent to EIPS.

Measure across the crowns of the strands with a caliper, never across the flats. The flat reading is smaller and makes the rope look one size down. New rope is made slightly oversize (up to +5 % per ASTM A1023, +2 to +5 % per EN 12385-4); a reduction of more than 5 % below nominal is a reason to retire it.

About Wire Rope

The breaking force is the minimum for new rope pulled straight. The working load limit is much lower: ASME B30.9 requires a 5:1 design factor for wire rope slings, cranes use 3.5:1 to 5:1 depending on the duty, and personnel lifting needs 10:1. Terminations reduce it further: a mechanical splice or swaged socket keeps 90–100 % of the rope strength, wire rope clips only about 80 %, a wedge socket 70–80 %.

6×19 class ropes have fewer, thicker wires: better abrasion and crushing resistance, less flexible. 6×36 class ropes have more, finer wires: more flexible and better on small sheaves and drums, but less resistant to abrasion and crushing. Both have the same strength ratings per size. IWRC ropes are about 7.5 % stronger than fibre-core (FC) ropes and resist crushing on drums; FC ropes are lighter and more flexible.

7×19 and 7×7 aircraft cable is a small, flexible galvanized or stainless rope for control cables, rigging, fencing and gym equipment. It has a strand core instead of an IWRC. Stainless 7×19 (type 302/304) is rated slightly lower than galvanized in most sizes.

Common constructions and where they are used

Typical choices; rope makers' catalogues give the details for each product.

ConstructionWires per strandTypical use
6×19 class IWRC15–26General purpose, slings, winches, haul ropes where abrasion matters
6×36 class IWRC27–49Cranes, hoists, slings needing flexibility, smaller sheaves
8×19 class15–26Elevator ropes and traction drives (fibre or steel core)
19×7 / 35×7 rotation-resistant7Single-part crane hoist lines, load must not spin
7×19 aircraft cable19Control cables, guy lines, gym equipment, rigging under 3/8 in
7×7 aircraft cable7Stiffer small cable: tension lines, fencing, 1/16–3/16 in

Sheave and drum size

Bending shortens rope life. Recommended minimum sheave diameter (D/d, sheave tread over rope diameter) from rope makers' tables: about 26 × d for 6×19, 18 × d for 6×36, 21 × d for 8×19. A 1/2 in 6×36 rope needs at least a 9 in sheave; the groove should be 6–10 % larger than the nominal rope diameter.

Questions

What is the breaking strength of 1/4 inch wire rope?

6×19 or 6×36 IWRC EIPS: 3.40 tons (6,800 lb); IPS: 2.94 tons (5,880 lb). 1/4 in 7×19 galvanized aircraft cable: 7,000 lb. Galvanized 6×19 rope is rated 10 % lower than bright.

How much can 3/8 wire rope lift?

Breaking strength for 3/8 in EIPS IWRC is 7.55 tons (15,100 lb). At the 5:1 design factor for slings the working load limit is 3,020 lb (1.37 t) on a straight vertical lift, before the efficiency of the termination.

What is the difference between IWRC and fibre core?

IWRC (independent wire rope core) is a small 7×7 wire rope in the centre. It is about 7.5 % stronger, resists crushing on drums and handles heat; fibre core rope is lighter, more flexible and holds lubricant.

Is 6×36 stronger than 6×19?

No, the same size and grade has the same rated breaking force in both classes. 6×36 is more flexible and better on small sheaves; 6×19 is more abrasion- and crush-resistant.

How do I measure wire rope diameter?

With a caliper across the crowns of opposite strands (the widest point), at two places at least 1 m (3 ft) apart, turning the caliper 90°. Average the readings. Measuring across the flats gives a falsely small reading.

Sources

  1. ASTM A1023/A1023M: Stranded Carbon Steel Wire Ropes for General Purposes
  2. US Federal Specification RR-W-410: Wire Rope and Strand
  3. Union (WireCo): 6×19 & 6×36 IWRC rope tables (IPS / XIP / XXIP)
  4. EN 12385-4: Steel wire ropes, stranded ropes for general lifting applications (breaking force factor K)
  5. Carl Stahl / Usha Martin: 6×36WS-IWRC 1960 minimum breaking force tables
  6. Engineering ToolBox: Wire ropes, strengths (6×19 IPS fibre core)
  7. MIL-DTL-83420: Wire rope, flexible, for aircraft control (7×7, 7×19); Lexco Cable catalogue
  8. ASME B30.9: Slings (5:1 design factor for wire rope slings)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.