V-Belt Size Chart: Cross-Sections
A V-belt is identified by its cross-section and its length. The section (A, B, SPZ, 5V, 4L …) fixes the top width and height and must match the pulley groove. A classical A belt is 13 mm wide and 8 mm high; the narrow SPA is 12.7 × 10 mm and carries much more power in the same groove width.
Section chartTap a section for its drawing and full specs
| Section | bTop widthmmin | hHeightmmin | bdDatum (pitch) widthmmin | Height / width | Pulley groove angle |
|---|---|---|---|---|---|
| Classical V-belts (ISO 4184 / DIN 2215) | |||||
| Z | 100.394 | 60.236 | 8.50.335 | 0.60 | 34° / 38° |
| A | 130.512 | 80.315 | 110.433 | 0.62 | 34° / 38° |
| B | 170.669 | 110.433 | 140.551 | 0.65 | 34° / 38° |
| C | 220.866 | 140.551 | 190.748 | 0.64 | 34° / 38° |
| D | 321.260 | 190.748 | 271.063 | 0.59 | 36° / 38° |
| E | 381.496 | 250.984 | 321.260 | 0.66 | 36° / 38° |
| Narrow wedge belts (ISO 4184 / DIN 7753, SP) | |||||
| SPZ | 9.70.382 | 80.315 | 8.50.335 | 0.82 | 34° / 38° |
| SPA | 12.70.500 | 100.394 | 110.433 | 0.79 | 34° / 38° |
| SPB | 16.30.642 | 130.512 | 140.551 | 0.80 | 34° / 38° |
| SPC | 220.866 | 180.709 | 190.748 | 0.82 | 34° / 38° |
| Narrow V-belts, inch (RMA 3V, 5V, 8V) | |||||
| 3V | 9.50.375 | 7.90.313 | — | 0.83 | 36°–42° |
| 5V | 15.90.625 | 13.50.531 | — | 0.85 | 38°–42° |
| 8V | 25.41.000 | 22.20.875 | — | 0.88 | 38°–42° |
| Light-duty FHP belts, inch (RMA 3L, 4L, 5L) | |||||
| 3L | 9.50.375 | 5.60.219 | — | 0.58 | — |
| 4L | 12.70.500 | 7.90.313 | — | 0.63 | — |
| 5L | 16.70.656 | 9.50.375 | — | 0.57 | — |
No exact match. The nearest sizes:
How to read a V-belt designation
Classical belts are named by a letter (Z, A, B, C, D, E) followed by the length, e.g. A 1250 Li (inside length 1250 mm) or A 1280 Ld (datum length). The same belt in inch catalogues is A48, the inside length in inches. The datum (pitch) length is a fixed amount longer for each section; take it from the maker's table.
Narrow wedge belts carry the SP prefix: SPZ 1250 is an SPZ section with a datum length (Ld or Lw) of 1250 mm. XPZ, XPA, XPB are the cogged versions of the same sections. Inch narrow belts are 3V, 5V, 8V followed by the effective outside length in tenths of an inch: 5V1000 is 100 in long; 5VX is the cogged version.
Light-duty FHP belts for small motors and lawn equipment use the L prefix: the first digit is the top width in eighths of an inch, the rest the outside length in tenths of an inch: 4L360 is 1/2 in wide and 36 in long. They look like A and B belts but are built for lighter loads.
To identify an unmarked belt, measure the top width and the height, then compare the ratio: classical belts are about 0.6 times as high as wide, narrow belts about 0.8. Measure the length with a tape around the outside, or over the pulley grooves, and convert with the maker's table.
About V-Belts
All V-belts have a 40° included angle; the pulley grooves are cut a little narrower (34° for small pulleys up to 38° for large ones) so that the belt wedges into the groove and transmits torque by friction on its flanks. The belt must never touch the bottom of the groove. If it does, it has worn or is the wrong section.
The datum width bd (pitch width, lp) is the width at the belt's neutral layer, the line that keeps its length when the belt bends. Pulley datum diameters and belt datum lengths refer to it. Classical and SP sections with the same datum width (A and SPA: 11 mm; B and SPB: 14 mm) run in the same pulley grooves, which is why SP belts are a common upgrade for classical drives.
Inch sections follow RMA (MPTA) standards: 3V, 5V and 8V are the narrow heavy-duty sections, close to SPZ, SPB and SPC but not identical; 3L, 4L and 5L are fractional-horsepower belts. The chart converts all inch sections to mm and back, but uses the nominal fractional sizes.
Classical or narrow?
For the same top width, a narrow (wedge) belt is deeper, has its cord closer to the full width, and transmits roughly 1.5 to 2 times the power of a classical belt. New industrial drives use SPZ–SPC or 3V/5V/8V; classical sections remain common on agricultural and older machines.
Belt length systems
Lengths are given as inside length (Li), datum or pitch length (Ld, Lw, Lp) or outside length (La, Le). For a given section they differ by a fixed amount, listed in every belt catalogue. Always check which length a catalogue number refers to before ordering.
Questions
What are the dimensions of an A section V-belt?
13 mm top width and 8 mm height (about 1/2 × 5/16 in), datum width 11 mm, 40° included angle.
What is the difference between SPA and A belts?
Both have an 11 mm datum width and fit the same pulleys. SPA is a narrow wedge belt, 12.7 × 10 mm, deeper than the 13 × 8 mm classical A, and carries considerably more power.
Can I use a 4L belt instead of an A belt?
The sections are nearly the same (1/2 in wide), but 4L belts are built for light-duty, fractional-horsepower drives. Replacing a 4L with an A belt is fine; using a 4L on an industrial A-belt drive usually shortens its life.
What does 5V1000 mean?
A 5V narrow section belt (5/8 in top width) with an effective outside length of 100.0 in.
How do I measure a V-belt?
Measure the top width and the height with a caliper to find the section, then the length: measure the outside length with a tape, or read it off the belt. Compare top width/height: about 0.6 means classical, about 0.8 narrow.
Sources
- ISO 4184:1992, Belt drives: Classical and narrow V-belts, Lengths in datum system
- DIN 7753-1: Endless narrow V-belts for machine construction (SPZ, SPA, SPB, SPC)
- DIN 2215: Endless classical V-belts
- RMA/MPTA IP-22: Narrow multiple V-belts (3V, 5V, 8V); IP-23: Light duty (FHP) V-belts
- Gates: Heavy duty V-belt drive design manual
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.