W10×26 Beam Dimensions & Properties

W Shapes (AISC) · W10: 10 in nominal depth

W10×26 is an AISC wide-flange shape (W10: 10 in nominal depth). It is 10.3 in (261.6 mm) deep with a 5.77 in (146.6 mm) flange, a 0.26 in (6.6 mm) web and a 0.44 in (11.2 mm) flange, and weighs 26 lb/ft (38.7 kg/m). Area 7.61 in² (4,910 mm²); strong-axis Ix = 144 in⁴ (5,993.7 cm⁴), Sx = 27.9 in³ (457.2 cm³), Zx = 31.3 in³ (512.9 cm³).

dDepth
261.6 mm10.3 in10.3 in261.6 mm
bfFlange width
146.6 mm5.77 in5.77 in146.6 mm
twWeb thickness
6.6 mm0.26 in0.26 in6.6 mm
tfFlange thickness
11.2 mm0.44 in0.44 in11.2 mm

Drawing

146.6 mm5.77 in261.6 mm10.3 intf 11.2 mmtf 0.44 intw 6.6 mmtw 0.26 ink 18.8 mmk 0.74 in
Drawn to scale · Dimensions in mmDimensions in inches

W10×26 specifications

dDepth10.3 in261.6 mm
bfFlange width5.77 in146.6 mm
twWeb thickness0.26 in6.6 mm
tfFlange thickness0.44 in11.2 mm
kDesign value0.74 in18.8 mm
kDetailing value1 1/16 in27.0 mm
k1Detailing value11/16 in17.5 mm
WWeight26 lb/ft38.7 kg/m
AArea7.61 in²4,910 mm²
IxMoment of inertia, strong axis144 in⁴5,993.7 cm⁴
ZxPlastic modulus, strong axis31.3 in³512.9 cm³
SxSection modulus, strong axis27.9 in³457.2 cm³
rxRadius of gyration, strong axis4.35 in110.5 mm
IyMoment of inertia, weak axis14.1 in⁴586.9 cm⁴
ZyPlastic modulus, weak axis7.5 in³122.9 cm³
SySection modulus, weak axis4.89 in³80.1 cm³
ryRadius of gyration, weak axis1.36 in34.5 mm
JTorsional constant0.402 in⁴16.73 cm⁴
bf/2tfFlange slenderness6.56
h/twWeb slenderness34
Metric designationW250×38.5

Also known as

W250×38.5

W shapes of about the same weight in other depths

All W Shapes (AISC) sizes

Compare all 289 shapes in the W Shapes (AISC) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
  2. ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.