W10×54 Beam Dimensions & Properties

W Shapes (AISC) · W10: 10 in nominal depth

W10×54 is an AISC wide-flange shape (W10: 10 in nominal depth). It is 10.1 in (256.5 mm) deep with a 10 in (254.0 mm) flange, a 0.37 in (9.4 mm) web and a 0.615 in (15.6 mm) flange, and weighs 54 lb/ft (80.4 kg/m). Area 15.8 in² (10,194 mm²); strong-axis Ix = 303 in⁴ (12,611.8 cm⁴), Sx = 60 in³ (983.2 cm³), Zx = 66.6 in³ (1,091.4 cm³).

dDepth
256.5 mm10.1 in10.1 in256.5 mm
bfFlange width
254.0 mm10 in10 in254.0 mm
twWeb thickness
9.4 mm0.37 in0.37 in9.4 mm
tfFlange thickness
15.6 mm0.615 in0.615 in15.6 mm

Drawing

254.0 mm10 in256.5 mm10.1 intf 15.6 mmtf 0.615 intw 9.4 mmtw 0.37 ink 28.4 mmk 1.12 in
Drawn to scale · Dimensions in mmDimensions in inches

W10×54 specifications

dDepth10.1 in256.5 mm
bfFlange width10 in254.0 mm
twWeb thickness0.37 in9.4 mm
tfFlange thickness0.615 in15.6 mm
kDesign value1.12 in28.4 mm
kDetailing value1 5/16 in33.3 mm
k1Detailing value13/16 in20.6 mm
WWeight54 lb/ft80.4 kg/m
AArea15.8 in²10,194 mm²
IxMoment of inertia, strong axis303 in⁴12,611.8 cm⁴
ZxPlastic modulus, strong axis66.6 in³1,091.4 cm³
SxSection modulus, strong axis60 in³983.2 cm³
rxRadius of gyration, strong axis4.37 in111.0 mm
IyMoment of inertia, weak axis103 in⁴4,287.2 cm⁴
ZyPlastic modulus, weak axis31.3 in³512.9 cm³
SySection modulus, weak axis20.6 in³337.6 cm³
ryRadius of gyration, weak axis2.56 in65.0 mm
JTorsional constant1.82 in⁴75.75 cm⁴
bf/2tfFlange slenderness8.15
h/twWeb slenderness21.2
Metric designationW250×80

Also known as

W250×80

W shapes of about the same weight in other depths

All W Shapes (AISC) sizes

Compare all 289 shapes in the W Shapes (AISC) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
  2. ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.