W12×79 Beam Dimensions & Properties
W Shapes (AISC) · W12: 12 in nominal depth
W12×79 is an AISC wide-flange shape (W12: 12 in nominal depth). It is 12.4 in (315.0 mm) deep with a 12.1 in (307.3 mm) flange, a 0.47 in (11.9 mm) web and a 0.735 in (18.7 mm) flange, and weighs 79 lb/ft (117.6 kg/m). Area 23.2 in² (14,968 mm²); strong-axis Ix = 662 in⁴ (27,554.5 cm⁴), Sx = 107 in³ (1,753.4 cm³), Zx = 119 in³ (1,950.1 cm³).
- dDepth
- 315.0 mm12.4 in12.4 in315.0 mm
- bfFlange width
- 307.3 mm12.1 in12.1 in307.3 mm
- twWeb thickness
- 11.9 mm0.47 in0.47 in11.9 mm
- tfFlange thickness
- 18.7 mm0.735 in0.735 in18.7 mm
Drawing
W12×79 specifications
| dDepth | 12.4 in315.0 mm |
|---|---|
| bfFlange width | 12.1 in307.3 mm |
| twWeb thickness | 0.47 in11.9 mm |
| tfFlange thickness | 0.735 in18.7 mm |
| kDesign value | 1.33 in33.8 mm |
| kDetailing value | 1 5/8 in41.3 mm |
| k1Detailing value | 1 1/16 in27.0 mm |
| WWeight | 79 lb/ft117.6 kg/m |
| AArea | 23.2 in²14,968 mm² |
| IxMoment of inertia, strong axis | 662 in⁴27,554.5 cm⁴ |
| ZxPlastic modulus, strong axis | 119 in³1,950.1 cm³ |
| SxSection modulus, strong axis | 107 in³1,753.4 cm³ |
| rxRadius of gyration, strong axis | 5.34 in135.6 mm |
| IyMoment of inertia, weak axis | 216 in⁴8,990.6 cm⁴ |
| ZyPlastic modulus, weak axis | 54.3 in³889.8 cm³ |
| SySection modulus, weak axis | 35.8 in³586.7 cm³ |
| ryRadius of gyration, weak axis | 3.05 in77.5 mm |
| JTorsional constant | 3.84 in⁴159.83 cm⁴ |
| bf/2tfFlange slenderness | 8.22 |
| h/twWeb slenderness | 20.7 |
| Metric designation | W310×117 |
Also known as
W310×117
W shapes of about the same weight in other depths
All W Shapes (AISC) sizes
Sources
- AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
- ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.