W18×76 Beam Dimensions & Properties

W Shapes (AISC) · W18: 18 in nominal depth

W18×76 is an AISC wide-flange shape (W18: 18 in nominal depth). It is 18.2 in (462.3 mm) deep with a 11 in (279.4 mm) flange, a 0.425 in (10.8 mm) web and a 0.68 in (17.3 mm) flange, and weighs 76 lb/ft (113.1 kg/m). Area 22.3 in² (14,387 mm²); strong-axis Ix = 1,330 in⁴ (55,358.8 cm⁴), Sx = 146 in³ (2,392.5 cm³), Zx = 163 in³ (2,671.1 cm³).

dDepth
462.3 mm18.2 in18.2 in462.3 mm
bfFlange width
279.4 mm11 in11 in279.4 mm
twWeb thickness
10.8 mm0.425 in0.425 in10.8 mm
tfFlange thickness
17.3 mm0.68 in0.68 in17.3 mm

Drawing

279.4 mm11 in462.3 mm18.2 intf 17.3 mmtf 0.68 intw 10.8 mmtw 0.425 ink 27.4 mmk 1.08 in
Drawn to scale · Dimensions in mmDimensions in inches

W18×76 specifications

dDepth18.2 in462.3 mm
bfFlange width11 in279.4 mm
twWeb thickness0.425 in10.8 mm
tfFlange thickness0.68 in17.3 mm
kDesign value1.08 in27.4 mm
kDetailing value1 9/16 in39.7 mm
k1Detailing value1 1/16 in27.0 mm
WWeight76 lb/ft113.1 kg/m
AArea22.3 in²14,387 mm²
IxMoment of inertia, strong axis1,330 in⁴55,358.8 cm⁴
ZxPlastic modulus, strong axis163 in³2,671.1 cm³
SxSection modulus, strong axis146 in³2,392.5 cm³
rxRadius of gyration, strong axis7.73 in196.3 mm
IyMoment of inertia, weak axis152 in⁴6,326.7 cm⁴
ZyPlastic modulus, weak axis42.2 in³691.5 cm³
SySection modulus, weak axis27.6 in³452.3 cm³
ryRadius of gyration, weak axis2.61 in66.3 mm
JTorsional constant2.83 in⁴117.79 cm⁴
bf/2tfFlange slenderness8.11
h/twWeb slenderness37.8
Metric designationW460×113

Also known as

W460×113

W shapes of about the same weight in other depths

All W Shapes (AISC) sizes

Compare all 289 shapes in the W Shapes (AISC) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
  2. ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.