W18×192 Beam Dimensions & Properties

W Shapes (AISC) · W18: 18 in nominal depth

W18×192 is an AISC wide-flange shape (W18: 18 in nominal depth). It is 20.4 in (518.2 mm) deep with a 11.5 in (292.1 mm) flange, a 0.96 in (24.4 mm) web and a 1.75 in (44.4 mm) flange, and weighs 192 lb/ft (285.7 kg/m). Area 56.2 in² (36,258 mm²); strong-axis Ix = 3,870 in⁴ (161,081.6 cm⁴), Sx = 380 in³ (6,227.1 cm³), Zx = 442 in³ (7,243.1 cm³).

dDepth
518.2 mm20.4 in20.4 in518.2 mm
bfFlange width
292.1 mm11.5 in11.5 in292.1 mm
twWeb thickness
24.4 mm0.96 in0.96 in24.4 mm
tfFlange thickness
44.4 mm1.75 in1.75 in44.4 mm

Drawing

292.1 mm11.5 in518.2 mm20.4 intf 44.4 mmtf 1.75 intw 24.4 mmtw 0.96 ink 54.6 mmk 2.15 in
Drawn to scale · Dimensions in mmDimensions in inches

W18×192 specifications

dDepth20.4 in518.2 mm
bfFlange width11.5 in292.1 mm
twWeb thickness0.96 in24.4 mm
tfFlange thickness1.75 in44.4 mm
kDesign value2.15 in54.6 mm
kDetailing value2 5/8 in66.7 mm
k1Detailing value1 5/16 in33.3 mm
WWeight192 lb/ft285.7 kg/m
AArea56.2 in²36,258 mm²
IxMoment of inertia, strong axis3,870 in⁴161,081.6 cm⁴
ZxPlastic modulus, strong axis442 in³7,243.1 cm³
SxSection modulus, strong axis380 in³6,227.1 cm³
rxRadius of gyration, strong axis8.28 in210.3 mm
IyMoment of inertia, weak axis440 in⁴18,314.2 cm⁴
ZyPlastic modulus, weak axis119 in³1,950.1 cm³
SySection modulus, weak axis76.8 in³1,258.5 cm³
ryRadius of gyration, weak axis2.79 in70.9 mm
JTorsional constant44.7 in⁴1,860.55 cm⁴
bf/2tfFlange slenderness3.27
h/twWeb slenderness16.7
Metric designationW460×286

Also known as

W460×286

W shapes of about the same weight in other depths

All W Shapes (AISC) sizes

Compare all 289 shapes in the W Shapes (AISC) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
  2. ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.