W36×210 Beam Dimensions & Properties

W Shapes (AISC) · W36: 36 in nominal depth

W36×210 is an AISC wide-flange shape (W36: 36 in nominal depth). It is 36.7 in (932.2 mm) deep with a 12.2 in (309.9 mm) flange, a 0.83 in (21.1 mm) web and a 1.36 in (34.5 mm) flange, and weighs 210 lb/ft (312.5 kg/m). Area 61.9 in² (39,935 mm²); strong-axis Ix = 13,200 in⁴ (549,425.5 cm⁴), Sx = 719 in³ (11,782.3 cm³), Zx = 833 in³ (13,650.4 cm³).

dDepth
932.2 mm36.7 in36.7 in932.2 mm
bfFlange width
309.9 mm12.2 in12.2 in309.9 mm
twWeb thickness
21.1 mm0.83 in0.83 in21.1 mm
tfFlange thickness
34.5 mm1.36 in1.36 in34.5 mm

Drawing

309.9 mm12.2 in932.2 mm36.7 intf 34.5 mmtf 1.36 intw 21.1 mmtw 0.83 ink 53.6 mmk 2.11 in
Drawn to scale · Dimensions in mmDimensions in inches

W36×210 specifications

dDepth36.7 in932.2 mm
bfFlange width12.2 in309.9 mm
twWeb thickness0.83 in21.1 mm
tfFlange thickness1.36 in34.5 mm
kDesign value2.11 in53.6 mm
kDetailing value2 5/8 in66.7 mm
k1Detailing value1 5/8 in41.3 mm
WWeight210 lb/ft312.5 kg/m
AArea61.9 in²39,935 mm²
IxMoment of inertia, strong axis13,200 in⁴549,425.5 cm⁴
ZxPlastic modulus, strong axis833 in³13,650.4 cm³
SxSection modulus, strong axis719 in³11,782.3 cm³
rxRadius of gyration, strong axis14.6 in370.8 mm
IyMoment of inertia, weak axis411 in⁴17,107.1 cm⁴
ZyPlastic modulus, weak axis107 in³1,753.4 cm³
SySection modulus, weak axis67.5 in³1,106.1 cm³
ryRadius of gyration, weak axis2.58 in65.5 mm
JTorsional constant28 in⁴1,165.45 cm⁴
bf/2tfFlange slenderness4.48
h/twWeb slenderness39.1
Metric designationW920×313

Also known as

W920×313

W shapes of about the same weight in other depths

All W Shapes (AISC) sizes

Compare all 289 shapes in the W Shapes (AISC) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
  2. ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.