W40×327 Beam Dimensions & Properties

W Shapes (AISC) · W40: 40 in nominal depth

W40×327 is an AISC wide-flange shape (W40: 40 in nominal depth). It is 40.8 in (1036.3 mm) deep with a 12.1 in (307.3 mm) flange, a 1.18 in (30.0 mm) web and a 2.13 in (54.1 mm) flange, and weighs 327 lb/ft (486.6 kg/m). Area 95.9 in² (61,871 mm²); strong-axis Ix = 24,500 in⁴ (1,019,767 cm⁴), Sx = 1,200 in³ (19,664.5 cm³), Zx = 1,410 in³ (23,105.8 cm³).

dDepth
1036.3 mm40.8 in40.8 in1036.3 mm
bfFlange width
307.3 mm12.1 in12.1 in307.3 mm
twWeb thickness
30.0 mm1.18 in1.18 in30.0 mm
tfFlange thickness
54.1 mm2.13 in2.13 in54.1 mm

Drawing

307.3 mm12.1 in1036.3 mm40.8 intf 54.1 mmtf 2.13 intw 30.0 mmtw 1.18 ink 84.1 mmk 3.31 in
Drawn to scale · Dimensions in mmDimensions in inches

W40×327 specifications

dDepth40.8 in1036.3 mm
bfFlange width12.1 in307.3 mm
twWeb thickness1.18 in30.0 mm
tfFlange thickness2.13 in54.1 mm
kDesign value3.31 in84.1 mm
kDetailing value3 3/8 in85.7 mm
k1Detailing value1 13/16 in46.0 mm
WWeight327 lb/ft486.6 kg/m
AArea95.9 in²61,871 mm²
IxMoment of inertia, strong axis24,500 in⁴1,019,767 cm⁴
ZxPlastic modulus, strong axis1,410 in³23,105.8 cm³
SxSection modulus, strong axis1,200 in³19,664.5 cm³
rxRadius of gyration, strong axis16 in406.4 mm
IyMoment of inertia, weak axis640 in⁴26,638.8 cm⁴
ZyPlastic modulus, weak axis170 in³2,785.8 cm³
SySection modulus, weak axis105 in³1,720.6 cm³
ryRadius of gyration, weak axis2.58 in65.5 mm
JTorsional constant103 in⁴4,287.18 cm⁴
bf/2tfFlange slenderness2.85
h/twWeb slenderness29
Metric designationW1000×486

Also known as

W1000×486

W shapes of about the same weight in other depths

All W Shapes (AISC) sizes

Compare all 289 shapes in the W Shapes (AISC) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
  2. ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.