W14×370 Beam Dimensions & Properties
W Shapes (AISC) · W14: 14 in nominal depth
W14×370 is an AISC wide-flange shape (W14: 14 in nominal depth). It is 17.9 in (454.7 mm) deep with a 16.5 in (419.1 mm) flange, a 1.66 in (42.2 mm) web and a 2.66 in (67.6 mm) flange, and weighs 370 lb/ft (550.6 kg/m). Area 109 in² (70,322 mm²); strong-axis Ix = 5,440 in⁴ (226,429.9 cm⁴), Sx = 607 in³ (9,946.9 cm³), Zx = 736 in³ (12,060.9 cm³).
- dDepth
- 454.7 mm17.9 in17.9 in454.7 mm
- bfFlange width
- 419.1 mm16.5 in16.5 in419.1 mm
- twWeb thickness
- 42.2 mm1.66 in1.66 in42.2 mm
- tfFlange thickness
- 67.6 mm2.66 in2.66 in67.6 mm
Drawing
W14×370 specifications
| dDepth | 17.9 in454.7 mm |
|---|---|
| bfFlange width | 16.5 in419.1 mm |
| twWeb thickness | 1.66 in42.2 mm |
| tfFlange thickness | 2.66 in67.6 mm |
| kDesign value | 3.26 in82.8 mm |
| kDetailing value | 3 15/16 in100.0 mm |
| k1Detailing value | 2 1/16 in52.4 mm |
| WWeight | 370 lb/ft550.6 kg/m |
| AArea | 109 in²70,322 mm² |
| IxMoment of inertia, strong axis | 5,440 in⁴226,429.9 cm⁴ |
| ZxPlastic modulus, strong axis | 736 in³12,060.9 cm³ |
| SxSection modulus, strong axis | 607 in³9,946.9 cm³ |
| rxRadius of gyration, strong axis | 7.07 in179.6 mm |
| IyMoment of inertia, weak axis | 1,990 in⁴82,830.1 cm⁴ |
| ZyPlastic modulus, weak axis | 370 in³6,063.2 cm³ |
| SySection modulus, weak axis | 241 in³3,949.3 cm³ |
| ryRadius of gyration, weak axis | 4.27 in108.5 mm |
| JTorsional constant | 222 in⁴9,240.34 cm⁴ |
| bf/2tfFlange slenderness | 3.1 |
| h/twWeb slenderness | 6.9 |
| Metric designation | W360×551 |
Also known as
W360×551
W shapes of about the same weight in other depths
All W Shapes (AISC) sizes
Sources
- AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
- ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.