W14×120 Beam Dimensions & Properties
W Shapes (AISC) · W14: 14 in nominal depth
W14×120 is an AISC wide-flange shape (W14: 14 in nominal depth). It is 14.5 in (368.3 mm) deep with a 14.7 in (373.4 mm) flange, a 0.59 in (15.0 mm) web and a 0.94 in (23.9 mm) flange, and weighs 120 lb/ft (178.6 kg/m). Area 35.3 in² (22,774 mm²); strong-axis Ix = 1,380 in⁴ (57,439.9 cm⁴), Sx = 190 in³ (3,113.5 cm³), Zx = 212 in³ (3,474.1 cm³).
- dDepth
- 368.3 mm14.5 in14.5 in368.3 mm
- bfFlange width
- 373.4 mm14.7 in14.7 in373.4 mm
- twWeb thickness
- 15.0 mm0.59 in0.59 in15.0 mm
- tfFlange thickness
- 23.9 mm0.94 in0.94 in23.9 mm
Drawing
W14×120 specifications
| dDepth | 14.5 in368.3 mm |
|---|---|
| bfFlange width | 14.7 in373.4 mm |
| twWeb thickness | 0.59 in15.0 mm |
| tfFlange thickness | 0.94 in23.9 mm |
| kDesign value | 1.54 in39.1 mm |
| kDetailing value | 2 1/4 in57.2 mm |
| k1Detailing value | 1 1/2 in38.1 mm |
| WWeight | 120 lb/ft178.6 kg/m |
| AArea | 35.3 in²22,774 mm² |
| IxMoment of inertia, strong axis | 1,380 in⁴57,439.9 cm⁴ |
| ZxPlastic modulus, strong axis | 212 in³3,474.1 cm³ |
| SxSection modulus, strong axis | 190 in³3,113.5 cm³ |
| rxRadius of gyration, strong axis | 6.24 in158.5 mm |
| IyMoment of inertia, weak axis | 495 in⁴20,603.5 cm⁴ |
| ZyPlastic modulus, weak axis | 102 in³1,671.5 cm³ |
| SySection modulus, weak axis | 67.5 in³1,106.1 cm³ |
| ryRadius of gyration, weak axis | 3.74 in95.0 mm |
| JTorsional constant | 9.37 in⁴390.01 cm⁴ |
| bf/2tfFlange slenderness | 7.8 |
| h/twWeb slenderness | 19.3 |
| Metric designation | W360×179 |
Also known as
W360×179
W shapes of about the same weight in other depths
All W Shapes (AISC) sizes
Sources
- AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
- ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.