W18×60 Beam Dimensions & Properties
W Shapes (AISC) · W18: 18 in nominal depth
W18×60 is an AISC wide-flange shape (W18: 18 in nominal depth). It is 18.2 in (462.3 mm) deep with a 7.56 in (192.0 mm) flange, a 0.415 in (10.5 mm) web and a 0.695 in (17.7 mm) flange, and weighs 60 lb/ft (89.3 kg/m). Area 17.6 in² (11,355 mm²); strong-axis Ix = 984 in⁴ (40,957.2 cm⁴), Sx = 108 in³ (1,769.8 cm³), Zx = 123 in³ (2,015.6 cm³).
- dDepth
- 462.3 mm18.2 in18.2 in462.3 mm
- bfFlange width
- 192.0 mm7.56 in7.56 in192.0 mm
- twWeb thickness
- 10.5 mm0.415 in0.415 in10.5 mm
- tfFlange thickness
- 17.7 mm0.695 in0.695 in17.7 mm
Drawing
W18×60 specifications
| dDepth | 18.2 in462.3 mm |
|---|---|
| bfFlange width | 7.56 in192.0 mm |
| twWeb thickness | 0.415 in10.5 mm |
| tfFlange thickness | 0.695 in17.7 mm |
| kDesign value | 1.1 in27.9 mm |
| kDetailing value | 1 3/8 in34.9 mm |
| k1Detailing value | 13/16 in20.6 mm |
| WWeight | 60 lb/ft89.3 kg/m |
| AArea | 17.6 in²11,355 mm² |
| IxMoment of inertia, strong axis | 984 in⁴40,957.2 cm⁴ |
| ZxPlastic modulus, strong axis | 123 in³2,015.6 cm³ |
| SxSection modulus, strong axis | 108 in³1,769.8 cm³ |
| rxRadius of gyration, strong axis | 7.47 in189.7 mm |
| IyMoment of inertia, weak axis | 50.1 in⁴2,085.3 cm⁴ |
| ZyPlastic modulus, weak axis | 20.6 in³337.6 cm³ |
| SySection modulus, weak axis | 13.3 in³217.9 cm³ |
| ryRadius of gyration, weak axis | 1.68 in42.7 mm |
| JTorsional constant | 2.17 in⁴90.32 cm⁴ |
| bf/2tfFlange slenderness | 5.44 |
| h/twWeb slenderness | 38.7 |
| Metric designation | W460×89 |
Also known as
W460×89
W shapes of about the same weight in other depths
All W Shapes (AISC) sizes
Sources
- AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
- ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.