W24×104 Beam Dimensions & Properties
W Shapes (AISC) · W24: 24 in nominal depth
W24×104 is an AISC wide-flange shape (W24: 24 in nominal depth). It is 24.1 in (612.1 mm) deep with a 12.8 in (325.1 mm) flange, a 0.5 in (12.7 mm) web and a 0.75 in (19.0 mm) flange, and weighs 104 lb/ft (154.8 kg/m). Area 30.7 in² (19,806 mm²); strong-axis Ix = 3,100 in⁴ (129,031.7 cm⁴), Sx = 258 in³ (4,227.9 cm³), Zx = 289 in³ (4,735.9 cm³).
- dDepth
- 612.1 mm24.1 in24.1 in612.1 mm
- bfFlange width
- 325.1 mm12.8 in12.8 in325.1 mm
- twWeb thickness
- 12.7 mm0.5 in0.5 in12.7 mm
- tfFlange thickness
- 19.0 mm0.75 in0.75 in19.0 mm
Drawing
W24×104 specifications
| dDepth | 24.1 in612.1 mm |
|---|---|
| bfFlange width | 12.8 in325.1 mm |
| twWeb thickness | 0.5 in12.7 mm |
| tfFlange thickness | 0.75 in19.0 mm |
| kDesign value | 1.25 in31.8 mm |
| kDetailing value | 2 1/16 in52.4 mm |
| k1Detailing value | 1 7/16 in36.5 mm |
| WWeight | 104 lb/ft154.8 kg/m |
| AArea | 30.7 in²19,806 mm² |
| IxMoment of inertia, strong axis | 3,100 in⁴129,031.7 cm⁴ |
| ZxPlastic modulus, strong axis | 289 in³4,735.9 cm³ |
| SxSection modulus, strong axis | 258 in³4,227.9 cm³ |
| rxRadius of gyration, strong axis | 10.1 in256.5 mm |
| IyMoment of inertia, weak axis | 259 in⁴10,780.4 cm⁴ |
| ZyPlastic modulus, weak axis | 62.4 in³1,022.6 cm³ |
| SySection modulus, weak axis | 40.7 in³667 cm³ |
| ryRadius of gyration, weak axis | 2.91 in73.9 mm |
| JTorsional constant | 4.72 in⁴196.46 cm⁴ |
| bf/2tfFlange slenderness | 8.5 |
| h/twWeb slenderness | 43.1 |
| Metric designation | W610×155 |
Also known as
W610×155
W shapes of about the same weight in other depths
All W Shapes (AISC) sizes
Sources
- AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
- ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.