W10×100 Beam Dimensions & Properties
W Shapes (AISC) · W10: 10 in nominal depth
W10×100 is an AISC wide-flange shape (W10: 10 in nominal depth). It is 11.1 in (281.9 mm) deep with a 10.3 in (261.6 mm) flange, a 0.68 in (17.3 mm) web and a 1.12 in (28.4 mm) flange, and weighs 100 lb/ft (148.8 kg/m). Area 29.3 in² (18,903 mm²); strong-axis Ix = 623 in⁴ (25,931.2 cm⁴), Sx = 112 in³ (1,835.4 cm³), Zx = 130 in³ (2,130.3 cm³).
- dDepth
- 281.9 mm11.1 in11.1 in281.9 mm
- bfFlange width
- 261.6 mm10.3 in10.3 in261.6 mm
- twWeb thickness
- 17.3 mm0.68 in0.68 in17.3 mm
- tfFlange thickness
- 28.4 mm1.12 in1.12 in28.4 mm
Drawing
W10×100 specifications
| dDepth | 11.1 in281.9 mm |
|---|---|
| bfFlange width | 10.3 in261.6 mm |
| twWeb thickness | 0.68 in17.3 mm |
| tfFlange thickness | 1.12 in28.4 mm |
| kDesign value | 1.62 in41.1 mm |
| kDetailing value | 1 13/16 in46.0 mm |
| k1Detailing value | 1 in25.4 mm |
| WWeight | 100 lb/ft148.8 kg/m |
| AArea | 29.3 in²18,903 mm² |
| IxMoment of inertia, strong axis | 623 in⁴25,931.2 cm⁴ |
| ZxPlastic modulus, strong axis | 130 in³2,130.3 cm³ |
| SxSection modulus, strong axis | 112 in³1,835.4 cm³ |
| rxRadius of gyration, strong axis | 4.6 in116.8 mm |
| IyMoment of inertia, weak axis | 207 in⁴8,616 cm⁴ |
| ZyPlastic modulus, weak axis | 61 in³999.6 cm³ |
| SySection modulus, weak axis | 40 in³655.5 cm³ |
| ryRadius of gyration, weak axis | 2.65 in67.3 mm |
| JTorsional constant | 10.9 in⁴453.69 cm⁴ |
| bf/2tfFlange slenderness | 4.62 |
| h/twWeb slenderness | 11.6 |
| Metric designation | W250×149 |
Also known as
W250×149
W shapes of about the same weight in other depths
All W Shapes (AISC) sizes
Sources
- AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
- ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.