W40×249 Beam Dimensions & Properties

W Shapes (AISC) · W40: 40 in nominal depth

W40×249 is an AISC wide-flange shape (W40: 40 in nominal depth). It is 39.4 in (1000.8 mm) deep with a 15.8 in (401.3 mm) flange, a 0.75 in (19.0 mm) web and a 1.42 in (36.1 mm) flange, and weighs 249 lb/ft (370.6 kg/m). Area 73.5 in² (47,419 mm²); strong-axis Ix = 19,600 in⁴ (815,813.6 cm⁴), Sx = 993 in³ (16,272.4 cm³), Zx = 1,120 in³ (18,353.5 cm³).

dDepth
1000.8 mm39.4 in39.4 in1000.8 mm
bfFlange width
401.3 mm15.8 in15.8 in401.3 mm
twWeb thickness
19.0 mm0.75 in0.75 in19.0 mm
tfFlange thickness
36.1 mm1.42 in1.42 in36.1 mm

Drawing

401.3 mm15.8 in1000.8 mm39.4 intf 36.1 mmtf 1.42 intw 19.0 mmtw 0.75 ink 66.0 mmk 2.6 in
Drawn to scale · Dimensions in mmDimensions in inches

W40×249 specifications

dDepth39.4 in1000.8 mm
bfFlange width15.8 in401.3 mm
twWeb thickness0.75 in19.0 mm
tfFlange thickness1.42 in36.1 mm
kDesign value2.6 in66.0 mm
kDetailing value2 11/16 in68.3 mm
k1Detailing value1 9/16 in39.7 mm
WWeight249 lb/ft370.6 kg/m
AArea73.5 in²47,419 mm²
IxMoment of inertia, strong axis19,600 in⁴815,813.6 cm⁴
ZxPlastic modulus, strong axis1,120 in³18,353.5 cm³
SxSection modulus, strong axis993 in³16,272.4 cm³
rxRadius of gyration, strong axis16.3 in414.0 mm
IyMoment of inertia, weak axis926 in⁴38,543 cm⁴
ZyPlastic modulus, weak axis182 in³2,982.4 cm³
SySection modulus, weak axis118 in³1,933.7 cm³
ryRadius of gyration, weak axis3.55 in90.2 mm
JTorsional constant38.1 in⁴1,585.84 cm⁴
bf/2tfFlange slenderness5.55
h/twWeb slenderness45.6
Metric designationW1000×371

Also known as

W1000×371

W shapes of about the same weight in other depths

All W Shapes (AISC) sizes

Compare all 289 shapes in the W Shapes (AISC) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
  2. ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.