D9/h9 Fit Tolerances

ISO Fits · Shaft-basis fits (h shaft)

D9/h9: Clearance fit, Shaft-basis fits (h shaft). At ⌀25 mm the hole is +117 / +65 µm, the shaft 0 / −52 µm, giving a maximum clearance of 169 µm and a minimum clearance of 65 µm (negative = interference). The table below lists the limits for every ISO size range up to 500 mm.

Fit type
Clearance
Max. clearance at ⌀25 mm
169 µm0.00665 in0.00665 in169 µm
Min. clearance at ⌀25 mm (− = interference)
65 µm0.00256 in0.00256 in65 µm

Drawing

zero line = nominal sizeHole D9Shaft h9+117+650−52⌀25 D9/h9: clearance 65 to 169 µm
Tolerance zones at ⌀25 mm, deviations in µm; vertical scale enlarged.Proportions shown, not to scale

D9/h9 specifications

Fit typeClearance
Hole limits at ⌀25 mm (µm)+117 / +65
Shaft limits at ⌀25 mm (µm)0 / −52
Max. clearance at ⌀25 mm169 µm0.00665 in
Min. clearance at ⌀25 mm (− = interference)65 µm0.00256 in

D9/h9 limits for every size range (µm)

Size (mm)Hole ES / EIShaft es / eiMax. clearanceMin. clearanceType
≤ 3+45 / +200 / −25+70+20clearance
3–6+60 / +300 / −30+90+30clearance
6–10+76 / +400 / −36+112+40clearance
10–18+93 / +500 / −43+136+50clearance
18–30+117 / +650 / −52+169+65clearance
30–50+142 / +800 / −62+204+80clearance
50–80+174 / +1000 / −74+248+100clearance
80–120+207 / +1200 / −87+294+120clearance
120–180+245 / +1450 / −100+345+145clearance
180–250+285 / +1700 / −115+400+170clearance
250–315+320 / +1900 / −130+450+190clearance
315–400+350 / +2100 / −140+490+210clearance
400–500+385 / +2300 / −155+540+230clearance

Shaft-basis free running fit for plain bearings on drawn shafting (h9).

Other fits of the same type (Clearance)

All ISO fits

Compare all 24 fits in the ISO Fits chart →

Sources

  1. ISO 286-1:2010, Geometrical product specifications (GPS): ISO code system for tolerances on linear sizes, Part 1: Basis of tolerances, deviations and fits
  2. ISO 286-2:2010, Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts
  3. ANSI B4.2-1978 (R2020): Preferred metric limits and fits

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.