H9/d9 Fit Tolerances

ISO Fits · Hole-basis fits (H hole)

H9/d9: Clearance fit, Hole-basis fits (H hole). At ⌀25 mm the hole is +52 / 0 µm, the shaft −65 / −117 µm, giving a maximum clearance of 169 µm and a minimum clearance of 65 µm (negative = interference). The table below lists the limits for every ISO size range up to 500 mm.

Fit type
Clearance
Max. clearance at ⌀25 mm
169 µm0.00665 in0.00665 in169 µm
Min. clearance at ⌀25 mm (− = interference)
65 µm0.00256 in0.00256 in65 µm

Drawing

zero line = nominal sizeHole H9Shaft d9+520−65−117⌀25 H9/d9: clearance 65 to 169 µm
Tolerance zones at ⌀25 mm, deviations in µm; vertical scale enlarged.Proportions shown, not to scale

H9/d9 specifications

Fit typeClearance
Hole limits at ⌀25 mm (µm)+52 / 0
Shaft limits at ⌀25 mm (µm)−65 / −117
Max. clearance at ⌀25 mm169 µm0.00665 in
Min. clearance at ⌀25 mm (− = interference)65 µm0.00256 in

H9/d9 limits for every size range (µm)

Size (mm)Hole ES / EIShaft es / eiMax. clearanceMin. clearanceType
≤ 3+25 / 0−20 / −45+70+20clearance
3–6+30 / 0−30 / −60+90+30clearance
6–10+36 / 0−40 / −76+112+40clearance
10–18+43 / 0−50 / −93+136+50clearance
18–30+52 / 0−65 / −117+169+65clearance
30–50+62 / 0−80 / −142+204+80clearance
50–80+74 / 0−100 / −174+248+100clearance
80–120+87 / 0−120 / −207+294+120clearance
120–180+100 / 0−145 / −245+345+145clearance
180–250+115 / 0−170 / −285+400+170clearance
250–315+130 / 0−190 / −320+450+190clearance
315–400+140 / 0−210 / −350+490+210clearance
400–500+155 / 0−230 / −385+540+230clearance

Free running fit. For loose bearings with large temperature variation, high speeds or heavy journal pressure; idler pulleys, plain bearings on long shafts.

Other fits of the same type (Clearance)

All ISO fits

Compare all 24 fits in the ISO Fits chart →

Sources

  1. ISO 286-1:2010, Geometrical product specifications (GPS): ISO code system for tolerances on linear sizes, Part 1: Basis of tolerances, deviations and fits
  2. ISO 286-2:2010, Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts
  3. ANSI B4.2-1978 (R2020): Preferred metric limits and fits

Values last checked against these sources on November 15, 2026. · How we check data