H11/c11 Fit Tolerances

ISO Fits · Hole-basis fits (H hole)

H11/c11: Clearance fit, Hole-basis fits (H hole). At ⌀25 mm the hole is +130 / 0 µm, the shaft −110 / −240 µm, giving a maximum clearance of 370 µm and a minimum clearance of 110 µm (negative = interference). The table below lists the limits for every ISO size range up to 500 mm.

Fit type
Clearance
Max. clearance at ⌀25 mm
370 µm0.01457 in0.01457 in370 µm
Min. clearance at ⌀25 mm (− = interference)
110 µm0.00433 in0.00433 in110 µm

Drawing

zero line = nominal sizeHole H11Shaft c11+1300−110−240⌀25 H11/c11: clearance 110 to 370 µm
Tolerance zones at ⌀25 mm, deviations in µm; vertical scale enlarged.Proportions shown, not to scale

H11/c11 specifications

Fit typeClearance
Hole limits at ⌀25 mm (µm)+130 / 0
Shaft limits at ⌀25 mm (µm)−110 / −240
Max. clearance at ⌀25 mm370 µm0.01457 in
Min. clearance at ⌀25 mm (− = interference)110 µm0.00433 in

H11/c11 limits for every size range (µm)

Size (mm)Hole ES / EIShaft es / eiMax. clearanceMin. clearanceType
≤ 3+60 / 0−60 / −120+180+60clearance
3–6+75 / 0−70 / −145+220+70clearance
6–10+90 / 0−80 / −170+260+80clearance
10–18+110 / 0−95 / −205+315+95clearance
18–30+130 / 0−110 / −240+370+110clearance
30–40+160 / 0−120 / −280+440+120clearance
40–50+160 / 0−130 / −290+450+130clearance
50–65+190 / 0−140 / −330+520+140clearance
65–80+190 / 0−150 / −340+530+150clearance
80–100+220 / 0−170 / −390+610+170clearance
100–120+220 / 0−180 / −400+620+180clearance
120–140+250 / 0−200 / −450+700+200clearance
140–160+250 / 0−210 / −460+710+210clearance
160–180+250 / 0−230 / −480+730+230clearance
180–200+290 / 0−240 / −530+820+240clearance
200–225+290 / 0−260 / −550+840+260clearance
225–250+290 / 0−280 / −570+860+280clearance
250–280+320 / 0−300 / −620+940+300clearance
280–315+320 / 0−330 / −650+970+330clearance
315–355+360 / 0−360 / −720+1080+360clearance
355–400+360 / 0−400 / −760+1120+400clearance
400–450+400 / 0−440 / −840+1240+440clearance
450–500+400 / 0−480 / −880+1280+480clearance

Loose running fit. Large clearance for rough, dirty or hot conditions: agricultural machinery, pins in clevises that must stay free, parts that will be painted or galvanized after machining.

Other fits of the same type (Clearance)

All ISO fits

Compare all 24 fits in the ISO Fits chart →

Sources

  1. ISO 286-1:2010, Geometrical product specifications (GPS): ISO code system for tolerances on linear sizes, Part 1: Basis of tolerances, deviations and fits
  2. ISO 286-2:2010, Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts
  3. ANSI B4.2-1978 (R2020): Preferred metric limits and fits

Values last checked against these sources on November 15, 2026. · How we check data

Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.