W24×176 Beam Dimensions & Properties

W Shapes (AISC) · W24: 24 in nominal depth

W24×176 is an AISC wide-flange shape (W24: 24 in nominal depth). It is 25.2 in (640.1 mm) deep with a 12.9 in (327.7 mm) flange, a 0.75 in (19.0 mm) web and a 1.34 in (34.0 mm) flange, and weighs 176 lb/ft (261.9 kg/m). Area 51.7 in² (33,355 mm²); strong-axis Ix = 5,680 in⁴ (236,419.4 cm⁴), Sx = 450 in³ (7,374.2 cm³), Zx = 511 in³ (8,373.8 cm³).

dDepth
640.1 mm25.2 in25.2 in640.1 mm
bfFlange width
327.7 mm12.9 in12.9 in327.7 mm
twWeb thickness
19.0 mm0.75 in0.75 in19.0 mm
tfFlange thickness
34.0 mm1.34 in1.34 in34.0 mm

Drawing

327.7 mm12.9 in640.1 mm25.2 intf 34.0 mmtf 1.34 intw 19.0 mmtw 0.75 ink 46.7 mmk 1.84 in
Drawn to scale · Dimensions in mmDimensions in inches

W24×176 specifications

dDepth25.2 in640.1 mm
bfFlange width12.9 in327.7 mm
twWeb thickness0.75 in19.0 mm
tfFlange thickness1.34 in34.0 mm
kDesign value1.84 in46.7 mm
kDetailing value2 5/8 in66.7 mm
k1Detailing value1 9/16 in39.7 mm
WWeight176 lb/ft261.9 kg/m
AArea51.7 in²33,355 mm²
IxMoment of inertia, strong axis5,680 in⁴236,419.4 cm⁴
ZxPlastic modulus, strong axis511 in³8,373.8 cm³
SxSection modulus, strong axis450 in³7,374.2 cm³
rxRadius of gyration, strong axis10.5 in266.7 mm
IyMoment of inertia, weak axis479 in⁴19,937.5 cm⁴
ZyPlastic modulus, weak axis115 in³1,884.5 cm³
SySection modulus, weak axis74.3 in³1,217.6 cm³
ryRadius of gyration, weak axis3.04 in77.2 mm
JTorsional constant23.9 in⁴994.79 cm⁴
bf/2tfFlange slenderness4.81
h/twWeb slenderness28.7
Metric designationW610×262

Also known as

W610×262

W shapes of about the same weight in other depths

All W Shapes (AISC) sizes

Compare all 289 shapes in the W Shapes (AISC) chart →

Sources

  1. AISC Shapes Database v16.0 (2023): dimensions and properties of the 16th Edition Steel Construction Manual
  2. ASTM A6/A6M: General requirements for rolled structural steel bars, plates, shapes and sheet piling (dimensions and tolerances)

Values last checked against these sources on November 15, 2026. · How we check data