Electrical Conduit Size Chart (EMT, IMC, Rigid, PVC, ENT, FMC)
Inside diameter, outside diameter and usable fill area of US electrical conduit by trade size, from NEC Chapter 9 Table 4, plus metric conduit sizes. A trade size is a name, not a measurement: 1" EMT has a 1.049" bore, 1" Schedule 80 PVC only 0.936", so the same wires that fit one may not fit the other.
Size chartTap a size for its drawing and full specs
| Conduit | Metric designator | ODOutside diametermminmm · in | IDInside diameter (nominal)mminmm · in | ATotal inside area (100 %)mm²in²mm² · in² | A₄₀Fill area, over 2 wires (40 %)mm²in²mm² · in² | Thread (EN 60423) |
|---|---|---|---|---|---|---|
| EMT: electrical metallic tubing | ||||||
| 1/2" EMT | 16 | 17.90.706 | 15.80.622 | 1960.304 | 790.122 | — |
| 3/4" EMT | 21 | 23.40.922 | 20.90.824 | 3440.533 | 1370.213 | — |
| 1" EMT | 27 | 29.51.163 | 26.61.049 | 5570.864 | 2230.346 | — |
| 1-1/4" EMT | 35 | 38.41.510 | 35.11.380 | 9651.496 | 3860.598 | — |
| 1-1/2" EMT | 41 | 44.21.740 | 40.91.610 | 1,3142.036 | 5250.814 | — |
| 2" EMT | 53 | 55.82.197 | 52.52.067 | 2,1653.356 | 8661.342 | — |
| 2-1/2" EMT | 63 | 73.02.875 | 69.42.731 | 3,7795.858 | 15122.343 | — |
| 3" EMT | 78 | 88.93.500 | 85.23.356 | 5,7078.846 | 22833.538 | — |
| 3-1/2" EMT | 91 | 101.64.000 | 97.43.834 | 7,44811.545 | 29794.618 | — |
| 4" EMT | 103 | 114.34.500 | 110.14.334 | 9,51814.753 | 38075.901 | — |
| IMC: intermediate metal conduit | ||||||
| 1/2" IMC | 16 | 20.70.815 | 16.80.660 | 2210.342 | 880.137 | — |
| 3/4" IMC | 21 | 26.11.029 | 21.90.864 | 3780.586 | 1510.234 | — |
| 1" IMC | 27 | 32.81.290 | 28.11.105 | 6190.959 | 2480.384 | — |
| 1-1/4" IMC | 35 | 41.61.638 | 36.81.448 | 1,0631.647 | 4250.659 | — |
| 1-1/2" IMC | 41 | 47.81.883 | 42.71.683 | 1,4352.225 | 5740.890 | — |
| 2" IMC | 53 | 59.92.360 | 54.62.150 | 2,3423.630 | 9371.452 | — |
| 2-1/2" IMC | 63 | 72.62.857 | 64.92.557 | 3,3135.135 | 13252.054 | — |
| 3" IMC | 78 | 88.33.476 | 80.73.176 | 5,1117.922 | 20453.169 | — |
| 3-1/2" IMC | 91 | 100.93.971 | 93.23.671 | 6,82810.584 | 27324.234 | — |
| 4" IMC | 103 | 113.44.466 | 105.84.166 | 8,79413.631 | 35175.452 | — |
| RMC: rigid metal conduit (GRC) | ||||||
| 1/2" RMC | 16 | 21.30.840 | 16.10.632 | 2030.314 | 810.126 | — |
| 3/4" RMC | 21 | 26.71.050 | 21.20.836 | 3540.549 | 1420.220 | — |
| 1" RMC | 27 | 33.41.315 | 27.01.063 | 5720.887 | 2290.355 | — |
| 1-1/4" RMC | 35 | 42.21.660 | 35.41.394 | 9851.526 | 3940.610 | — |
| 1-1/2" RMC | 41 | 48.31.900 | 41.21.624 | 1,3362.071 | 5340.828 | — |
| 2" RMC | 53 | 60.32.375 | 52.92.083 | 2,1993.408 | 8791.363 | — |
| 2-1/2" RMC | 63 | 73.02.875 | 63.22.489 | 3,1394.866 | 12551.946 | — |
| 3" RMC | 78 | 88.93.500 | 78.53.090 | 4,8387.499 | 19353.000 | — |
| 3-1/2" RMC | 91 | 101.64.000 | 90.73.570 | 6,45810.010 | 25834.004 | — |
| 4" RMC | 103 | 114.34.500 | 102.94.050 | 8,31112.882 | 33255.153 | — |
| 5" RMC | 129 | 141.35.563 | 128.95.073 | 13,04020.212 | 52168.085 | — |
| 6" RMC | 155 | 168.36.625 | 154.86.093 | 18,81229.158 | 752511.663 | — |
| PVC Schedule 40 | ||||||
| 1/2" PVC Sch 40 | 16 | 21.30.840 | 15.30.602 | 1840.285 | 740.114 | — |
| 3/4" PVC Sch 40 | 21 | 26.71.050 | 20.40.804 | 3280.508 | 1310.203 | — |
| 1" PVC Sch 40 | 27 | 33.41.315 | 26.11.029 | 5370.832 | 2150.333 | — |
| 1-1/4" PVC Sch 40 | 35 | 42.21.660 | 34.51.360 | 9371.453 | 3750.581 | — |
| 1-1/2" PVC Sch 40 | 41 | 48.31.900 | 40.41.590 | 1,2811.986 | 5120.794 | — |
| 2" PVC Sch 40 | 53 | 60.32.375 | 52.02.047 | 2,1233.291 | 8491.316 | — |
| 2-1/2" PVC Sch 40 | 63 | 73.02.875 | 62.12.445 | 3,0294.695 | 12121.878 | — |
| 3" PVC Sch 40 | 78 | 88.93.500 | 77.33.042 | 4,6897.268 | 18752.907 | — |
| 3-1/2" PVC Sch 40 | 91 | 101.64.000 | 89.43.521 | 6,2829.737 | 25133.895 | — |
| 4" PVC Sch 40 | 103 | 114.34.500 | 101.53.998 | 8,09912.554 | 32405.022 | — |
| 5" PVC Sch 40 | 129 | 141.35.563 | 127.45.016 | 12,74919.761 | 50997.904 | — |
| 6" PVC Sch 40 | 155 | 168.36.625 | 153.26.031 | 18,43028.567 | 737211.427 | — |
| PVC Schedule 80 | ||||||
| 1/2" PVC Sch 80 | 16 | 21.30.840 | 13.40.526 | 1400.217 | 560.087 | — |
| 3/4" PVC Sch 80 | 21 | 26.71.050 | 18.30.722 | 2640.409 | 1060.164 | — |
| 1" PVC Sch 80 | 27 | 33.41.315 | 23.80.936 | 4440.688 | 1770.275 | — |
| 1-1/4" PVC Sch 80 | 35 | 42.21.660 | 31.91.255 | 7981.237 | 3190.495 | — |
| 1-1/2" PVC Sch 80 | 41 | 48.31.900 | 37.51.476 | 1,1041.711 | 4410.684 | — |
| 2" PVC Sch 80 | 53 | 60.32.375 | 48.61.913 | 1,8542.874 | 7421.150 | — |
| 2-1/2" PVC Sch 80 | 63 | 73.02.875 | 58.22.290 | 2,6574.119 | 10631.648 | — |
| 3" PVC Sch 80 | 78 | 88.93.500 | 72.72.864 | 4,1566.442 | 16632.577 | — |
| 3-1/2" PVC Sch 80 | 91 | 101.64.000 | 84.53.326 | 5,6058.688 | 22423.475 | — |
| 4" PVC Sch 80 | 103 | 114.34.500 | 96.23.786 | 7,26311.258 | 29054.503 | — |
| 5" PVC Sch 80 | 129 | 141.35.563 | 121.14.768 | 11,51917.855 | 46087.142 | — |
| 6" PVC Sch 80 | 155 | 168.36.625 | 145.05.709 | 16,51525.598 | 660610.239 | — |
| ENT: electrical nonmetallic tubing | ||||||
| 1/2" ENT | 16 | — | 14.20.560 | 1590.246 | 630.098 | — |
| 3/4" ENT | 21 | — | 19.30.760 | 2930.454 | 1170.182 | — |
| 1" ENT | 27 | — | 25.41.000 | 5060.785 | 2030.314 | — |
| 1-1/4" ENT | 35 | — | 34.01.340 | 9101.410 | 3640.564 | — |
| 1-1/2" ENT | 41 | — | 39.91.570 | 1,2491.936 | 4990.774 | — |
| 2" ENT | 53 | — | 51.32.020 | 2,0683.205 | 8271.282 | — |
| FMC: flexible metal conduit | ||||||
| 3/8" FMC | 12 | — | 9.80.384 | 750.116 | 300.046 | — |
| 1/2" FMC | 16 | — | 16.10.635 | 2050.317 | 820.127 | — |
| 3/4" FMC | 21 | — | 20.90.824 | 3440.533 | 1370.213 | — |
| 1" FMC | 27 | — | 25.91.020 | 5270.817 | 2110.327 | — |
| 1-1/4" FMC | 35 | — | 32.41.275 | 8241.277 | 3300.511 | — |
| 1-1/2" FMC | 41 | — | 39.11.538 | 1,1991.858 | 4790.743 | — |
| 2" FMC | 53 | — | 51.82.040 | 2,1093.269 | 8441.308 | — |
| 2-1/2" FMC | 63 | — | 63.52.500 | 3,1674.909 | 12671.964 | — |
| 3" FMC | 78 | — | 76.23.000 | 4,5617.069 | 18252.828 | — |
| 3-1/2" FMC | 91 | — | 88.93.500 | 6,2079.621 | 24833.848 | — |
| 4" FMC | 103 | — | 101.64.000 | 8,10712.566 | 32435.026 | — |
| Metric conduit (EN 61386) | ||||||
| 16 mm | — | 16.00.630 | — | — | — | M16 × 1.5 |
| 20 mm | — | 20.00.787 | — | — | — | M20 × 1.5 |
| 25 mm | — | 25.00.984 | — | — | — | M25 × 1.5 |
| 32 mm | — | 32.01.260 | — | — | — | M32 × 1.5 |
| 40 mm | — | 40.01.575 | — | — | — | M40 × 1.5 |
| 50 mm | — | 50.01.969 | — | — | — | M50 × 1.5 |
| 63 mm | — | 63.02.480 | — | — | — | M63 × 1.5 |
No exact match. The nearest sizes:
How conduit fill works
NEC Chapter 9 Table 1 limits the cross-section that conductors may occupy: 53 % of the conduit's inside area for one conductor, 31 % for two, 40 % for three or more. Table 4 gives the inside area of each conduit type and trade size (the areas in this chart), and Table 5 the area of each insulated conductor: 0.0133 in² for 12 AWG THHN, 0.0211 in² for 10 AWG.
To check a run, add up the areas of all conductors (equipment grounding conductors count) and compare with the allowed area: three 12 AWG THHN plus one 12 AWG ground = 4 × 0.0133 = 0.0532 in², well inside the 0.122 in² of 1/2" EMT. For conductors all of the same size, Annex C lists the result directly; Chapter 9 Note 7 lets you round up when the calculation ends in .8 or more.
The metric designator is the NEC's metric name for the trade size (1/2 = 16, 3/4 = 21, 1 = 27, 2 = 53). It is not the outside diameter in mm and does not correspond to IEC metric conduit, which is named by its outside diameter (a 20 mm conduit is 20 mm OD).
About Conduit Sizes
All rigid conduit types of one trade size share roughly the same outside diameter so that fittings, knockouts and supports fit: RMC and PVC have exactly the pipe OD (1" = 1.315"), IMC is slightly smaller, EMT clearly smaller (1" EMT = 1.163"). The bore differs by type because the walls do: thin-wall EMT has the largest inside area of the steel types, Schedule 80 PVC the smallest of all.
ENT and FMC are corrugated or spirally wound, so their outside diameter varies by manufacturer; the NEC gives only the inside dimensions used for fill. Liquidtight flexible conduit (LFMC, LFNC) has its own rows in Table 4 and is not listed here.
Metric conduit (IEC/EN 61386, used in Europe, the UK, Australia and much of Asia) is designated by outside diameter (16, 20, 25, 32, 40, 50, 63 mm) and threaded M16 × 1.5 to M63 × 1.5 to EN 60423, the same threads as metric cable glands. Inside diameters depend on whether the conduit is light, medium or heavy duty and on the maker, so they are not tabulated here.
Jam ratio and pulling
With exactly three conductors, check the jam ratio: conduit ID ÷ conductor OD. Between 2.8 and 3.2 the three wires can wedge side by side in a bend, so pull carefully or change the size. The 40 % fill limit does not cover this. It is a separate pulling check, as are bend limits (no more than 360° of bends between pull points).
Derating is separate
Fill compliance does not make the ampacity right. More than three current-carrying conductors in one raceway require the adjustment factors of NEC 310.15(C)(1): 80 % for 4–6 conductors, 70 % for 7–9, 50 % for 10–20. Check this whenever you fill a conduit to the limit.
Questions
How many 12 AWG wires fit in 3/4 inch EMT?
16 THHN conductors at the 40 % limit: 0.213 in² ÷ 0.0133 in² = 16.0. In 1/2" EMT it is 9, in 1" EMT 26. Remember to count the ground wire and to derate ampacity above three current-carrying conductors.
What is the actual inside diameter of 1 inch conduit?
It depends on the type: EMT 1.049", rigid 1.063", IMC 1.105", PVC Schedule 40 1.029", PVC Schedule 80 0.936", FMC 1.020" (NEC Chapter 9 Table 4).
Why is conduit fill limited to 40 %?
To leave room for heat to escape and to let the conductors be pulled without damaging the insulation. With one conductor the limit is 53 %, with two only 31 %, because two round wires jam more easily than three.
What size is 20 mm conduit in inches?
20 mm metric conduit has a 20 mm (0.787") outside diameter, between US 1/2" EMT (0.706") and 1/2" rigid (0.840"). Metric and US conduit and fittings are not interchangeable.
Is Schedule 40 PVC conduit the same size as rigid steel?
The outside diameter is the same (both use pipe ODs, e.g. 2.375" for 2"), so the same knockouts and straps fit. The bore of Schedule 40 PVC is slightly smaller: 2.047" against 2.083" for 2" rigid.
Sources
- NFPA 70 (National Electrical Code), Chapter 9 Tables 1, 4 and 5
- NECA/IBEW: NEC Chapter 9 Table 4, Dimensions and percent area of conduit and tubing
- Wheatland Tube: EMT and conduit brochure (ANSI C80.1 / C80.3 / C80.6 dimensions)
- Steel Tube Institute: Intermediate metal conduit
- PDHonline E276: Conduit fill calculations (NEC Chapter 9 worked examples)
- IEC 61386-1 / EN 61386: Conduit systems for cable management; EN 60423: conduit outside diameters and threads
Values last checked against these sources on November 15, 2026. · How we check data
Reference values for planning and identification. Confirm critical dimensions with the manufacturer's drawing or the current edition of the standard before production.